Language English USD Currency
Call WhatsApp RFQ
Schneider Electric Industrial Automation Part

Schneider ATV310HU40N4 Replacement for Altivar 310

Request availability, condition, lead time and export shipping details for ATV310HU40N4.

Schneider Electric

ATV310HU40N4

Send this exact part number, quantity and destination country. TOPNLMS will confirm availability, condition and export lead time before quotation.

Part NumberATV310HU40N4
CategoryVFD
ConditionAvailability Check
Lead TimeRFQ Confirmation
SeriesAltivar
ShippingExport packing available
Model checked before quotation Condition and packing confirmed Fast RFQ response by sales engineer

Product Overview

Schneider ATV310HU40N4 Replacement for Altivar 310: Seamless Transition & Smooth Upgrade

The Schneider Electric ATV310HU40N4 is a 4kW, 400V three-phase variable frequency drive from the Altivar 310 series — a compact, field-proven drive platform widely deployed across pump, fan, conveyor, and general-purpose motor control applications in industrial facilities worldwide. As the Altivar 310 series approaches end-of-life and spare parts become increasingly scarce, many plant engineers and maintenance teams are now evaluating direct replacement or controlled migration strategies to maintain production continuity and reduce unplanned downtime.

At TOPNLMS, we supply the ATV310HU40N4 as a verified replacement unit — tested, inspected, and ready to ship — to support both emergency breakdown recovery and planned system modernization projects. Whether you are replacing a failed drive on a critical production line or executing a phased upgrade of your motor control infrastructure, this guide covers everything you need to know about wiring compatibility, communication protocol migration, physical installation, and system commissioning.

Compatibility Comparison Table

Parameter Legacy / Outgoing Model ATV310HU40N4 (Replacement)
Series Altivar 31 (ATV31) / ATV312 Altivar 310 (ATV310)
Power Rating 4kW (5.5HP) 4kW (5.5HP)
Supply Voltage 380–460V AC, 3-Phase 380–460V AC, 3-Phase
Output Current ~9.5A (ATV31) / 9.5A (ATV312) 9.5A
Control Terminals Screw-type, compatible pinout Screw-type, compatible pinout
Communication Protocol Modbus RTU (RS-485) Modbus RTU (RS-485) — native
Mounting Style DIN rail / panel mount DIN rail / panel mount
Enclosure Rating IP20 IP20
Programming Interface Keypad / SoMove software Integrated keypad / SoMove software
Braking Resistor Support External (optional) External (optional)
Replacement Recommendation Direct drop-in for ATV31HU40N4 and ATV312HU40N4 with minor parameter re-entry
Warranty 12-Month Warranty (TOPNLMS)

Seamless Upgrade Solutions

A successful ATV310HU40N4 migration rarely involves the drive alone. In most retrofit projects, the surrounding system components must be evaluated and, in many cases, replaced or reconfigured alongside the drive to ensure reliable, long-term operation.

For installations where the existing control cabinet uses a legacy Modbus RTU network, the ATV310HU40N4’s built-in RS-485 port allows direct integration without additional communication gateways. However, if your system relies on CANopen or DeviceNet — common in older Schneider Altivar 31 deployments — you may need to add a VW3A3608 or VW3A3609 fieldbus option card to bridge the protocol gap. These option cards slot directly into the ATV310 drive and are available as accessories.

In multi-drive panel installations, the ATV310HU40N4 is typically paired with a Schneider TeSys D-series contactor (LC1D series) and a GV2 or GV3 motor circuit breaker for upstream protection. If your existing panel uses older LC1-D09 or LC1-D12 contactors, these remain fully compatible with the ATV310’s output terminals and do not require replacement during the drive swap.

For I/O expansion and signal conditioning, many Altivar 310 retrofit projects incorporate Schneider Advantys STB or Modicon TM3 I/O modules to extend digital and analog signal capacity without redesigning the control architecture. If your legacy system used a Modicon TSX Micro or Modicon M340 PLC as the master controller, the ATV310HU40N4 communicates natively over Modbus RTU, allowing the existing PLC program to remain largely unchanged — only the drive node address and parameter register mapping may require minor adjustment.

Power supply integrity is critical during any drive replacement. Ensure the 24VDC control power supply feeding the ATV310’s logic terminals — often an ABL8 or Phaseo power supply unit — is rated for the control circuit load. In older installations, aging power supplies are a common secondary failure point discovered during drive replacement, and proactively replacing the ABL8REM24030 or equivalent unit during the same maintenance window eliminates a future call-back.

For commissioning and parameter transfer, the VW3A1104 SoMove Bluetooth module or a standard USB-RJ45 programming cable allows technicians to upload saved parameter files from the old drive directly into the ATV310HU40N4 using Schneider’s SoMove desktop software, dramatically reducing on-site commissioning time. If the original drive’s parameters were not backed up, TOPNLMS can provide a baseline parameter template for common pump and fan applications upon request.

In applications where the motor cable run exceeds 50 meters, installing a dV/dt output filter or a Schneider VW3A4421 sine filter between the ATV310HU40N4 and the motor is strongly recommended to protect motor winding insulation — particularly important when the replacement motor is an older, non-inverter-duty unit inherited from the legacy system.

Retrofit Guidance FAQ

Q: Can I reuse the existing motor wiring from my ATV31 or ATV312 installation?
A: Yes. The ATV310HU40N4 uses the same U/V/W output terminal configuration as the ATV31 and ATV312 series. Existing motor cables can be reconnected directly, provided the cable cross-section and insulation rating are appropriate for the 4kW output current (9.5A). Verify cable condition and terminal torque specifications before energizing.

Q: Do I need to reprogram my PLC after replacing the drive?
A: In most cases, no. If your PLC communicates with the drive via Modbus RTU, the ATV310HU40N4 uses the same register map structure as the ATV312. You will need to verify the drive’s Modbus node address (parameter COM-) and baud rate settings match your existing network configuration. Parameter re-entry from a saved SoMove file takes approximately 10–15 minutes on-site.

Q: Is the physical footprint of the ATV310HU40N4 the same as the ATV31HU40N4?
A: The ATV310 series has a slightly different enclosure profile compared to the ATV31. Panel cutout dimensions and DIN rail mounting positions may require minor adjustment. We recommend downloading the ATV310HU40N4 dimensional drawing from Schneider’s documentation library and comparing it against your existing panel layout before installation.

Q: What communication protocols does the ATV310HU40N4 support natively?
A: The ATV310HU40N4 includes native Modbus RTU (RS-485) as standard. CANopen, DeviceNet, PROFIBUS DP, and EtherNet/IP are supported via optional fieldbus cards (VW3A36xx series). This makes the ATV310 compatible with a wide range of existing PLC and SCADA architectures without requiring network infrastructure changes.

Q: Can the ATV310HU40N4 be used as a direct replacement for a failed ATV312HU40N4?
A: Yes. The ATV310HU40N4 is the designated successor to the ATV312 series for this power class. Power terminals, control wiring, and Modbus communication are compatible. Parameter migration via SoMove software is straightforward, and most installations can be returned to service within one to two hours of on-site work.

Q: What if my application requires a braking resistor?
A: The ATV310HU40N4 supports an external braking resistor connected to the PA/+ and PB terminals. If your existing installation used a braking resistor with the ATV31 or ATV312, verify the resistor’s ohmic value and power rating against the ATV310 specifications. In most 4kW applications, the existing resistor can be reused without modification.

Warranty Assurance

Every ATV310HU40N4 unit shipped by TOPNLMS is covered by a 12-month warranty from the date of delivery. Our pre-shipment inspection process includes functional power-on testing, output voltage verification across all three phases, control terminal continuity checks, and communication port validation. Units that do not pass inspection are not shipped.

In the event of a warranty claim, TOPNLMS provides a replacement unit or full refund within the warranty period. Our after-sales response target is 24 hours for initial assessment and 72 hours for replacement dispatch. We maintain buffer stock of high-demand Altivar 310 series drives specifically to support rapid warranty replacements without extended lead times.

For procurement teams managing planned maintenance budgets, TOPNLMS can provide advance purchase agreements, consignment stock arrangements, and multi-unit pricing for ATV310 series drives. All units are sourced through verified supply channels and include original manufacturer packaging and documentation where available.

For technical pre-sales support, commissioning guidance, or bulk procurement inquiries, contact our team directly:

Quick Inquiry

Click Quote This Model and the Part Number field will auto-fill with ATV310HU40N4.