Honeywell 113228/U Original Industrial Spare UV Compatible
113228/UHoneywell 113228/U original UV flame sensor for RM7800 & R7847 burner management systems. OEM spare, industrial replacement, 12-month warranty, fast dispatch.
Request availability, condition, lead time and export shipping details for FSB-200.
Send this exact part number, quantity and destination country. TOPNLMS will confirm availability, condition and export lead time before quotation.
The Honeywell FSB-200 Reflected Beam Smoke Detector is a proven, high-reliability solution for facilities seeking a direct replacement or upgrade path from legacy System Sensor beam detector installations. Whether your existing fire detection infrastructure relies on aging reflected beam units, conventional loop wiring, or discontinued detector heads that no longer meet current fire codes, the FSB-200 delivers a smooth migration with minimal disruption to your installed base.
Industrial facilities, warehouses, data centers, and large open-space environments frequently encounter the challenge of maintaining fire detection coverage when original equipment manufacturers discontinue legacy models. The FSB-200 is engineered to address exactly this scenario — providing a compatible footprint, familiar wiring topology, and equivalent optical performance that allows maintenance teams to execute a like-for-like swap without redesigning the entire fire alarm system.
When migrating from older reflected beam detectors such as the System Sensor BEAM1224S or BEAM1224FS series, engineers will find that the FSB-200 retains the same fundamental two-wire or four-wire loop compatibility, depending on the fire alarm control panel (FACP) configuration. The detector’s adjustable sensitivity range and built-in alignment LED simplify on-site commissioning, reducing the skilled labor hours typically associated with beam detector replacement projects. Facilities currently operating Notifier, Simplex, or Edwards fire alarm control panels will find the FSB-200 integrates cleanly into existing supervised loop architectures without requiring panel firmware upgrades or additional interface modules in most standard configurations.
For projects involving partial system modernization — where only the field devices are being replaced while the FACP and wiring infrastructure remain — the FSB-200’s backward-compatible signal output eliminates the need for signal conditioners or relay modules that older replacement units sometimes require. This is particularly valuable in retrofit scenarios where conduit runs are fixed and pulling new cable is cost-prohibitive.
| Parameter | Legacy / Outgoing Model | Honeywell FSB-200 |
|---|---|---|
| Detector Type | Reflected Beam Smoke Detector | Reflected Beam Smoke Detector |
| Typical Legacy Models | System Sensor BEAM1224S, BEAM1224FS, older Hochiki or Apollo beam units | FSB-200 (direct replacement) |
| Operating Voltage | 12–24 VDC (conventional loop) | 12–24 VDC |
| Wiring Interface | 2-wire or 4-wire supervised loop | 2-wire or 4-wire supervised loop |
| Detection Range | Typically 5–100 m | Up to 100 m (reflector included) |
| Sensitivity Adjustment | Fixed or limited adjustment | Adjustable (25%, 40%, 50% obscuration) |
| Mounting Compatibility | Standard back-box or surface mount | Standard back-box or surface mount |
| FACP Compatibility | Notifier, Simplex, Edwards, Hochiki panels | Compatible with major conventional and addressable panels |
| Alignment Indicator | Varies by model | Built-in alignment LED for fast commissioning |
| Replacement Recommendation | Discontinued / EOL models | Direct drop-in replacement recommended |
| Warranty | Expired / no longer supported | 12-Month Warranty from TOPNLMS |
A successful beam detector migration rarely involves a single component swap. In practice, the FSB-200 replacement project typically proceeds alongside a broader review of the fire detection loop infrastructure. Facilities upgrading from legacy beam detectors frequently find that the associated conventional zone modules, relay output cards, and end-of-line resistor assemblies also require attention. Where the existing fire alarm control panel uses a Notifier NFS-320 or NFS2-3030 series panel, the FSB-200 connects directly to the conventional zone input without additional interface hardware.
In larger installations where the beam detector feeds into an addressable loop via a monitor module — such as a System Sensor M500M or equivalent addressable interface — the FSB-200’s dry contact relay output provides a clean signal handoff, preserving the addressable loop integrity. For facilities transitioning from older Hochiki DCP or Apollo XP95 addressable systems, a compatible addressable interface module bridges the FSB-200 into the new loop architecture without requiring a full panel replacement.
Projects that include simultaneous replacement of conventional heat detectors, manual call points, or sounder bases will benefit from sourcing compatible Honeywell System Sensor series accessories — including the BEAM200R reflector kit, which is included with the FSB-200 and eliminates the need for a separate reflector procurement. Where ceiling-mounted beam detectors are being replaced alongside duct smoke detectors such as the System Sensor DUCT150 or D4120, coordinating the replacement schedule minimizes total system downtime and allows a single commissioning visit to cover all field devices.
For facilities that also operate gas detection or multi-sensor panels alongside their fire detection infrastructure, the FSB-200’s standard relay output integrates cleanly with building management system (BMS) input cards, allowing fire alarm status to be monitored centrally without additional signal conditioning hardware.
Q: Can the FSB-200 use the existing wiring from my old beam detector?
In most cases, yes. The FSB-200 is designed for 2-wire and 4-wire supervised loop configurations standard in conventional fire alarm systems. Provided the existing cable gauge and loop resistance are within specification, no rewiring is required. Always verify loop resistance and insulation integrity before commissioning.
Q: Do I need to reprogram my fire alarm control panel after replacing the beam detector?
For conventional zone-based panels, no programming changes are typically required — the FSB-200 presents the same electrical characteristics as a standard conventional detector. For addressable systems using a monitor module interface, the module address and zone assignment remain unchanged.
Q: Is the FSB-200 compatible with my existing reflector?
The FSB-200 includes the BEAM200R reflector. If your existing reflector is in good condition and correctly positioned, it may be reused, but Honeywell recommends using the supplied reflector to ensure optimal optical alignment and sensitivity calibration.
Q: How long does physical installation take?
A trained fire alarm technician can typically complete a like-for-like beam detector swap in 1–2 hours per detector, including alignment, sensitivity adjustment, and functional test. The built-in alignment LED significantly reduces the time required compared to older models without visual alignment aids.
Q: What if my installation space has changed since the original detector was installed?
The FSB-200 supports a detection range of up to 100 meters and includes adjustable mounting hardware. Minor changes in ceiling height or structural obstructions can be accommodated by adjusting the sensitivity setting and reflector position during commissioning.
Q: Can the FSB-200 be used in dusty or high-humidity industrial environments?
The FSB-200 is rated for use in challenging environments typical of warehouses, manufacturing facilities, and industrial plants. Consult the product datasheet for specific IP rating and environmental operating limits to confirm suitability for your application.
Every Honeywell FSB-200 unit shipped by TOPNLMS is covered by a 12-month warranty from the date of delivery. Prior to dispatch, each unit undergoes functional verification to confirm optical alignment, sensitivity response, and electrical output integrity. This pre-shipment testing protocol ensures that field installation proceeds without defective-unit delays — a critical consideration for projects with tight commissioning schedules or regulatory inspection deadlines.
In the event of a warranty claim, TOPNLMS provides direct replacement support with priority processing for customers engaged in active retrofit or system modernization projects. Our after-sales response team is reachable via email and phone to coordinate replacement logistics, technical documentation, and any required compliance certificates for your project records.
Stock is maintained in Xiamen for fast domestic and international dispatch. Standard lead times for in-stock units are 1–3 business days for domestic China shipments, with international express options available for urgent replacement requirements. Bulk procurement inquiries for multi-site retrofit programs are welcome — contact our team for volume pricing and consolidated shipping arrangements.
Purchasing through TOPNLMS provides full traceability documentation, including product origin records and test reports, supporting your facility’s maintenance and compliance audit requirements.
Click Quote This Model and the Part Number field will auto-fill with FSB-200.