Honeywell 113228/U Original Industrial Spare UV Compatible
113228/UHoneywell 113228/U original UV flame sensor for RM7800 & R7847 burner management systems. OEM spare, industrial replacement, 12-month warranty, fast dispatch.
Request availability, condition, lead time and export shipping details for 330103-02-06-10-02-00.
Send this exact part number, quantity and destination country. TOPNLMS will confirm availability, condition and export lead time before quotation.
The HONEYWELL 330103-02-06-10-02-00 is an 8 mm eddy-current proximity probe engineered for continuous shaft vibration, axial position, and eccentricity monitoring in rotating machinery. As legacy Bently Nevada 3300 Series installations reach end-of-service life or face discontinued spare-part availability, this probe provides a validated, drop-in replacement path that preserves existing wiring infrastructure, conditioner compatibility, and system calibration — minimizing both engineering rework and unplanned downtime.
This probe operates on the standard Bently Nevada eddy-current measurement principle: a high-frequency oscillator drives the probe tip coil, and changes in the gap between the probe tip and the conductive target shaft alter the oscillator’s output voltage. The resulting DC voltage signal is fed directly into a compatible proximitor/extension cable assembly — such as the 330130 series extension cable and 3300 XL 8mm Proximitor — without requiring signal conditioning hardware changes. Engineers migrating from earlier 330103 variants or from third-party probes will find the electrical interface, connector pinout, and sensitivity specification (nominally 7.87 V/mm or 200 mV/mil) fully consistent with the installed Bently Nevada ecosystem.
| Parameter | Legacy / Replaced Model | 330103-02-06-10-02-00 (This Unit) |
|---|---|---|
| Probe Series | Bently Nevada 3300 / 7200 Series (8mm) | Bently Nevada 3300 XL 8mm Compatible |
| Measurement Type | Eddy-Current (Non-contact) | Eddy-Current (Non-contact) |
| Sensitivity | 200 mV/mil (7.87 V/mm) | 200 mV/mil (7.87 V/mm) — identical |
| Probe Tip Diameter | 8 mm | 8 mm |
| Cable Length | Varies (0.5 m / 1 m) | 0.5 m integral cable (extension via 330130) |
| Connector Type | Standard BN coaxial (MIL-C-17) | Standard BN coaxial (MIL-C-17) — direct mate |
| Proximitor Compatibility | 3300 XL Proximitor / 3300 RAM | 3300 XL Proximitor / 3300 RAM — confirmed |
| Installation Thread | M10 × 1.0 | M10 × 1.0 — no bracket modification required |
| Operating Temperature | −35 °C to +177 °C | −35 °C to +177 °C |
| Target Material | AISI 4140 / 4340 steel shaft | AISI 4140 / 4340 steel shaft — same calibration |
| Signal Output | −24 VDC bias (nominal) | −24 VDC bias (nominal) — no reconfiguration |
| Replacement Recommendation | Direct drop-in; no rewiring | ✔ Confirmed drop-in replacement |
| Warranty | — | 12-Month Warranty (TOPNLMS) |
A successful migration from a legacy vibration monitoring system to a 330103-02-06-10-02-00-based installation typically involves coordinating several interdependent components. The probe itself connects to the field junction via a 330130 series extension cable, which routes the signal from the machine casing to the monitor rack without introducing impedance mismatches. At the rack level, the signal is received by a 3300 XL 8mm Proximitor module — the active signal conditioning unit that converts the probe’s oscillator output into a calibrated DC voltage readable by the monitor card.
For plants running a full Bently Nevada 3500 Series rack architecture, the probe signal feeds into a 3500/42M Proximitor/Seismic Monitor or a 3500/40M Proximitor Monitor card, both of which accept the standard 200 mV/mil sensitivity input without firmware changes. Sites that have already migrated their I/O to a DCS backbone — such as a Honeywell Experion PKS or a Yokogawa CENTUM VP — can route the 4–20 mA converted output through a signal isolator/converter module to maintain galvanic isolation between the field loop and the control system analog input card.
Where the existing conduit and terminal block layout must be preserved, a DIN-rail mounted terminal block assembly (e.g., Phoenix Contact or Weidmüller style) allows the extension cable shield to be properly grounded at a single point, preventing ground loops that would otherwise introduce noise into the vibration signal. For commissioning and gap-setting verification, a Bently Nevada 330180 proximitor power supply or equivalent bench supply is used alongside a digital multimeter to confirm the −24 VDC bias and linear output range before the machine is returned to service.
Plants upgrading multiple measurement points simultaneously often replace the 3300 RAM (Rack Adapter Module) in the same outage window, as this module manages the power distribution and I/O routing for all proximity channels in the rack. Pairing the probe replacement with a 3500/20 Rack Interface Module upgrade ensures the entire signal chain — from probe tip to historian — is operating on current firmware and hardware revisions, reducing the risk of intermittent faults caused by aging backplane connectors. For sites decommissioning older Bently Nevada 7200 Series probes in parallel, the 330103-02-06-10-02-00 serves as a unified replacement across both 3300 and 7200 platform installations, simplifying spare-part inventory management.
Q: Can I reuse the existing extension cable when replacing the probe?
A: Yes, provided the existing 330130 extension cable is undamaged and its connector is free of corrosion. Inspect the coaxial connector and cable jacket before reuse. If the cable has been exposed to high-temperature or chemical environments, replace it simultaneously to avoid introducing a new failure point.
Q: Do I need to recalibrate the proximitor after installing this probe?
A: If the replacement probe is the same model (330103-02-06-10-02-00) and the gap is reset to the original specification (typically 1.0–1.5 mm for a −10 to −12 VDC output), recalibration of the proximitor is not required. Verify the output voltage at the nominal gap using a non-conductive gap-setting tool before returning the machine to service.
Q: Is the thread pitch compatible with my existing probe holder/bracket?
A: Yes. The 330103-02-06-10-02-00 uses an M10 × 1.0 thread, which is the standard for all Bently Nevada 8mm proximity probes. No bracket modification or adapter is required.
Q: Can this probe be used with a 3500 Series monitor rack instead of a 3300 Series?
A: Yes. The 3500 Series Proximitor Monitor cards (3500/40M, 3500/42M) are fully compatible with 3300 XL 8mm probes. The sensitivity and bias voltage specifications are identical, and no configuration changes are needed in the monitor card.
Q: What communication protocol does the monitor system use, and does the probe affect it?
A: The proximity probe itself is a passive analog sensor; it does not participate in any digital communication protocol. The monitor card (e.g., 3500/42M) handles Modbus RTU, FOUNDATION Fieldbus, or Profibus DP communication to the DCS or SCADA system. Replacing the probe has no effect on the communication configuration.
Q: How much physical space is required for installation?
A: The probe body requires approximately 25 mm of radial clearance from the shaft centerline to the probe tip, plus the M10 thread engagement depth (minimum 10 mm). The integral cable exits axially and requires a minimum bend radius of 50 mm. These dimensions are identical to all standard 8mm Bently Nevada probes, so no casing modification is needed.
Q: Can this probe replace discontinued Bently Nevada 7200 Series probes?
A: Yes, in most installations. The 7200 Series used the same 8mm eddy-current principle and MIL-C-17 coaxial connector. Verify the proximitor model and sensitivity setting before installation; no wiring changes are typically required.
Every 330103-02-06-10-02-00 unit shipped by TOPNLMS is covered by a 12-month warranty from the date of delivery. Prior to dispatch, each probe undergoes functional verification including oscillator frequency check, sensitivity measurement at a calibrated gap, and connector integrity inspection. Units that do not meet Bently Nevada specification tolerances are quarantined and not shipped.
In the event of a confirmed defect within the warranty period, TOPNLMS will arrange a replacement unit at no additional cost. Our technical support team is available to assist with installation questions, gap-setting guidance, and compatibility verification before and after purchase. Typical dispatch from our Xiamen warehouse is 1–3 business days for in-stock units, with DHL Express, FedEx International Priority, and sea freight options available depending on order volume and destination.
For bulk procurement, OEM replacement programs, or urgent plant shutdown requirements, please contact our sales team directly to discuss lead times, quantity pricing, and consignment stocking arrangements.
Click Quote This Model and the Part Number field will auto-fill with 330103-02-06-10-02-00.