The Schneider Electric LV432693 MICROLOGIC 6.0A electronic trip unit is a precision-engineered original spare component designed for Masterpact NT and NW series air circuit breakers. In industrial facilities where power distribution reliability is non-negotiable, this trip unit serves as the intelligent core of your ACB — governing overload protection, short-circuit response, and earth fault detection with factory-calibrated accuracy. Sourced directly from Schneider Electric’s authorized supply chain, this unit is verified original, fully tested, and ready for immediate field deployment.
Whether you are managing a planned shutdown, responding to an unscheduled outage, or building a strategic spare parts inventory for a critical MCC or switchgear panel, the LV432693 is the correct replacement for aging or failed MICROLOGIC 6.0A trip units across the Masterpact NT/NW platform. Its plug-in design ensures zero-modification installation, preserving your existing breaker frame, wiring, and protection settings.
| Parameter | Specification |
|---|---|
| Part Number | LV432693 |
| Model / SKU | MICROLOGIC 6.0A |
| Brand | Schneider Electric |
| Series Compatibility | Masterpact NT (630A–1600A), Masterpact NW (800A–6300A) |
| Protection Functions | Long-time (Ir), Short-time (Isd), Instantaneous (Ii), Earth fault (Ig) |
| Trip Unit Type | Electronic, Ammeter function (A-type) |
| Rated Current Setting (Ir) | 0.4 × In to 1 × In (adjustable) |
| Communication | Not included (standalone metering version) |
| Mounting | Plug-in, tool-free replacement |
| Operating Temperature | -25°C to +70°C |
| Ingress Protection | IP40 (installed in breaker) |
| Country of Origin | France |
| Condition | Original, New-in-Box |
| Warranty | 12 Months from date of shipment |
| Pre-shipment Testing | Full functional verification performed |
| Typical Application | MCC panels, main distribution boards, industrial switchgear, power substations |
A failed or degraded MICROLOGIC 6.0A trip unit rarely fails in isolation. In most industrial environments, the Masterpact ACB operates as part of a broader low-voltage power distribution system, and a comprehensive maintenance strategy requires evaluating the entire electrical circuit — not just the breaker itself.
When replacing the LV432693 trip unit during a scheduled outage or emergency repair, maintenance engineers should simultaneously inspect the Masterpact NT/NW auxiliary contact blocks (such as the OF/SD/SDE contact modules) for mechanical wear and contact oxidation. These auxiliary contacts feed status signals to your SCADA or BMS system, and degraded contacts can cause false tripping alarms or missed fault signals — a silent risk in automated facilities.
The Masterpact motor mechanism (MCH) — the motorized charging module — should also be checked for proper spring tension and cycle count. In high-cycle applications such as automatic transfer switching or bus-tie operations, the MCH accumulates mechanical fatigue independently of the trip unit’s electronic health. Stocking a spare MCH module alongside the LV432693 is a recognized best practice in facilities with redundant power architectures.
Downstream of the ACB, inspect the Schneider Electric Canalis busbar trunking connections or cable lug terminations for thermal discoloration, which may indicate sustained overload conditions that accelerated the original trip unit’s degradation. If the facility uses PowerLogic PM series power meters (e.g., PM710, PM800) upstream or downstream of the Masterpact, verify that metering data aligns with the new trip unit’s Ir and Isd settings post-replacement to confirm protection coordination.
For facilities running Schneider Electric Prisma or Okken switchgear panels, the replacement of a MICROLOGIC trip unit is an ideal trigger point to audit the panel’s Vigirex RH series residual current relays and associated toroidal current transformers. These components share the same maintenance interval as the ACB and are frequently overlooked during reactive repairs. Similarly, the Sepam series protection relays installed in medium-voltage feeders supplying the LV distribution board should be verified for correct upstream coordination settings after any LV protection parameter change.
If your facility uses Acti9 iC60 or iDT40 miniature circuit breakers in the downstream distribution boards fed by the Masterpact, this is also the right time to verify that downstream MCB ratings remain correctly coordinated with the newly configured MICROLOGIC 6.0A settings — particularly the Isd (short-time delay) threshold, which directly affects selectivity. Maintaining a small buffer stock of Acti9 iC60N 3P MCBs and iID residual current circuit breakers (RCCBs) ensures that downstream protection can be restored rapidly if a fault propagates during the ACB maintenance window.
Finally, document the replacement in your CMMS with the new trip unit’s serial number, calibration settings, and test results. Pairing the LV432693 with a Schneider Electric ECOFIT maintenance kit — which includes contact kits and arc chute assemblies for the Masterpact frame — extends the overall breaker service life and defers the capital cost of a full ACB replacement by several maintenance cycles.
The MICROLOGIC 6.0A (LV432693) is the direct, OEM-specified replacement for earlier MICROLOGIC 5.0A and 6.0A variants used in legacy Masterpact NT1, NT2, NT3, NW08, NW10, NW16, NW20, NW25, NW32, NW40, NW50, and NW63 frames. Unlike third-party aftermarket trip units, the LV432693 retains full compatibility with Schneider Electric’s EcoStruxure Power Commission software for parameter upload/download, trip curve verification, and remote diagnostics — a critical advantage for facilities that have invested in digital power management infrastructure.
For plants operating aging Masterpact M or Compact NS series breakers alongside newer Masterpact NT/NW equipment, the MICROLOGIC 6.0A platform provides a consistent protection philosophy across the distribution board, simplifying engineer training and reducing the risk of misconfiguration during emergency repairs. The plug-in replacement architecture means a trained electrician can complete the swap in under 30 minutes without specialized tooling, dramatically reducing MTTR (Mean Time to Repair) compared to full breaker replacement.
Procurement teams managing multi-site industrial facilities are advised to maintain at least one LV432693 unit per Masterpact NT/NW frame size in their regional spare parts depot. Given typical lead times for electrical protection components, on-shelf availability of this trip unit can be the difference between a 30-minute repair and a multi-day production shutdown.
Q1: Is the LV432693 MICROLOGIC 6.0A compatible with all Masterpact NT and NW frame sizes?
Yes. The MICROLOGIC 6.0A trip unit is compatible with the full Masterpact NT range (630A to 1600A) and the Masterpact NW range (800A to 6300A). It uses a standardized plug-in interface common across all NT/NW frames. Always verify the frame generation (H1/H2/H3) against Schneider Electric’s compatibility matrix before installation if your breaker predates 2005.
Q2: How is the unit tested before shipment?
Every LV432693 unit shipped from TOPNLMS undergoes a full functional verification including continuity checks, protection function activation tests, and visual inspection for physical integrity. A test report is available upon request. Units are packed in anti-static, shock-resistant packaging to prevent transit damage.
Q3: What does the 12-month warranty cover?
The 12-month warranty covers manufacturing defects and functional failures under normal operating conditions from the date of shipment. It does not cover damage resulting from incorrect installation, overvoltage events beyond rated specifications, or unauthorized modification. Warranty claims are processed within 5 business days of receipt of the returned unit.
Q4: Can I use this trip unit to replace a MICROLOGIC 5.0A in an existing Masterpact frame?
The MICROLOGIC 6.0A adds earth fault protection (Ig function) not present in the 5.0A variant. The physical plug-in interface is identical, so the swap is mechanically compatible. However, you must update your protection coordination study to account for the additional Ig function and reconfigure the trip unit settings to match your system’s earth fault protection requirements. Consult your power system engineer before substituting protection levels.
Click Quote This Model and the Part Number field will auto-fill with LV432693.