Phoenix Contact 2866802 Original Industrial Spare QUINT-PS Compatible
2866802Phoenix Contact 2866802 QUINT-PS/3AC/24DC/40 original industrial spare. Three-phase 24VDC 40A DIN-rail PSU. 12-month warranty. Fast global shipping. In stock.
Request availability, condition, lead time and export shipping details for QUINT-PS/1AC/24DC/5.
Send this exact part number, quantity and destination country. TOPNLMS will confirm availability, condition and export lead time before quotation.
In modern industrial environments, power supply reliability is the foundation of every control system. The Phoenix Contact QUINT-PS/1AC/24DC/5 (Part No. 2866750) is a proven, original-grade DIN rail power supply from the renowned QUINT-PS series — engineered for demanding 24 VDC applications where consistent output, thermal resilience, and long service life are non-negotiable. Whether you are managing a PLC cabinet, a distributed I/O rack, or a legacy DCS panel, this unit delivers the stable 5 A output your field devices depend on.
For maintenance engineers and procurement teams responsible for keeping production lines running, sourcing an original spare like the QUINT-PS/1AC/24DC/5 is a strategic decision — not just a parts order. Unplanned downtime caused by a failed power supply can cascade across an entire control loop, affecting sensors, actuators, communication modules, and HMI panels simultaneously. Stocking a verified original replacement eliminates that risk and shortens mean time to repair (MTTR) dramatically.
| Parameter | Specification |
|---|---|
| Part Number | 2866750 |
| Full SKU | QUINT-PS/1AC/24DC/5 |
| Brand / Series | Phoenix Contact / QUINT-PS |
| Input Voltage | 85–264 VAC (1-phase AC), 90–350 VDC |
| Output Voltage | 24 VDC (adjustable 18–29.5 VDC) |
| Output Current | 5 A nominal |
| Output Power | 120 W |
| Mounting | DIN rail (EN 60715 TH 35) |
| Protection Class | IP20 |
| Operating Temperature | -25 °C to +70 °C |
| Efficiency | ≥ 93% |
| Approvals | UL, cUL, CE, GL, DNV |
| Country of Origin | Germany |
| Compatibility | QUINT-PS series; direct replacement for legacy QUINT4-PS/1AC/24DC/5 |
| Warranty | 12 Months |
A power supply failure rarely occurs in isolation. When the QUINT-PS/1AC/24DC/5 is flagged for replacement during a scheduled shutdown or emergency inspection, experienced maintenance teams use the opportunity to audit the entire power distribution chain within the control cabinet. This approach — replacing or verifying adjacent components while the cabinet is already open — significantly reduces the probability of a secondary failure within the next maintenance cycle.
Begin with the 24 VDC bus terminal blocks and distribution terminals (such as Phoenix Contact PT series or PTFIX junction blocks). Loose or corroded terminal connections are a leading cause of intermittent voltage drops that stress the power supply output stage over time. While the cabinet is de-energized, inspect and re-torque all terminal connections feeding downstream field devices.
Next, evaluate the Phoenix Contact QUINT-PS/1AC/24DC/10 or QUINT-PS/3AC/24DC/20 units if your panel includes higher-current zones — these QUINT-PS siblings share the same mounting footprint and wiring philosophy, making cross-training and spare-parts standardization straightforward. If your facility runs multiple cabinets, standardizing on the QUINT-PS family across all panels simplifies your spare parts inventory to a manageable set of two or three SKUs.
Inspect the Phoenix Contact QUINT-BUFFER/24DC/USV/24DC/24DC/40 or equivalent UPS buffer modules if your system requires ride-through capability during brief mains interruptions. Buffer modules paired with the QUINT-PS/1AC/24DC/5 provide seamless power continuity for PLCs and safety relays during grid fluctuations — a common scenario in facilities with heavy motor loads on the same electrical circuit.
Check the 24 VDC relay output modules and safety relay modules (e.g., Phoenix Contact PSR-SCP series) that are powered from this supply rail. These modules are often overlooked during routine inspections but are directly affected by supply voltage quality. A degraded power supply can cause marginal relay coil energization, leading to intermittent output faults that are difficult to diagnose without a stable reference voltage.
For systems using Phoenix Contact Axioline F or Inline I/O modules, verify that the 24 VDC supply feeding the I/O bus coupler is within specification. I/O modules operating at the edge of their input voltage tolerance exhibit increased error rates and communication timeouts — symptoms that are frequently misdiagnosed as PLC program faults or fieldbus issues rather than power quality problems.
Finally, review the Phoenix Contact TRABTECH surge protection devices (VAL-MS series) installed on the incoming AC supply line. A failed or degraded surge arrester provides no protection to the power supply during the next transient event. Replacing surge protection devices on a 3–5 year cycle is a low-cost measure that protects significantly more expensive downstream assets including the QUINT-PS unit itself.
The QUINT-PS/1AC/24DC/5 (2866750) is a direct, form-fit-function replacement for earlier QUINT-PS generation units used in legacy control panels installed over the past two decades. Its DIN rail footprint, terminal layout, and 24 VDC output characteristics are fully compatible with existing wiring harnesses, meaning field replacement can typically be completed within 15–30 minutes by a qualified technician — without any panel rewiring or PLC reconfiguration.
For facilities managing aging automation infrastructure, the QUINT-PS series represents a cost-effective path to extending system life without committing to a full panel upgrade. Rather than replacing an entire PLC rack or DCS marshalling cabinet because the original power supply is obsolete, sourcing an original QUINT-PS/1AC/24DC/5 spare restores full system functionality at a fraction of the capital cost. This approach is particularly valuable in industries with long equipment depreciation cycles — such as water treatment, chemical processing, oil and gas, and discrete manufacturing — where control systems routinely operate for 15–25 years.
Each unit supplied by TOPNLMS is sourced from verified supply channels, functionally tested prior to dispatch, and shipped with full traceability documentation. Our 12-month warranty covers manufacturing defects and functional failures under normal operating conditions, giving your procurement and maintenance teams the confidence to stock this unit as a long-term strategic spare.
Q1: Is the QUINT-PS/1AC/24DC/5 2866750 compatible with my existing QUINT-PS panel wiring?
Yes. The QUINT-PS/1AC/24DC/5 (2866750) maintains the same DIN rail mounting dimensions, terminal block layout, and 24 VDC output specification as previous QUINT-PS generation units. In most installations, replacement requires only disconnecting the existing terminals, removing the old unit, snapping in the new unit, and reconnecting — no rewiring or reconfiguration required. Always verify your specific panel drawing before installation.
Q2: What does the 12-month warranty cover, and what is the claims process?
The 12-month warranty covers functional failures and manufacturing defects under normal operating conditions (within rated voltage, current, and temperature specifications). If a unit fails within the warranty period, contact us at [email protected] with your order number and a brief fault description. We will arrange a replacement or repair with minimal lead time to keep your maintenance schedule on track.
Q3: How should I manage spare parts inventory for QUINT-PS units across multiple panels?
For facilities with 5 or more panels using QUINT-PS/1AC/24DC/5 units, we recommend maintaining a minimum of 2 spare units on-site. Power supplies in continuous industrial service typically have a field service life of 7–12 years depending on ambient temperature and load profile. Proactive replacement at the 8–10 year mark — before failure — eliminates unplanned downtime. Bulk procurement pricing is available; contact us for volume quotation.
Q4: How is the unit tested before shipment?
Every QUINT-PS/1AC/24DC/5 unit is functionally tested under load prior to dispatch. Testing verifies output voltage accuracy, current limiting behavior, and thermal performance. Units are packed in anti-static, shock-resistant packaging with individual labeling for traceability. Typical dispatch lead time is 1–3 business days from order confirmation.
Click Quote This Model and the Part Number field will auto-fill with QUINT-PS/1AC/24DC/5.