Language English USD Currency
Call WhatsApp RFQ
Phoenix Contact Industrial Automation Part

Phoenix Contact QUINT-PS/1AC/24DC/10 Original Industrial Spare QUINT Compatible

Request availability, condition, lead time and export shipping details for QUINT-PS/1AC/24DC/10.

Phoenix Contact

QUINT-PS/1AC/24DC/10

Send this exact part number, quantity and destination country. TOPNLMS will confirm availability, condition and export lead time before quotation.

Part NumberQUINT-PS/1AC/24DC/10
CategoryPower Supply
ConditionAvailability Check
Lead TimeRFQ Confirmation
SeriesOther series
ShippingExport packing available
Model checked before quotation Condition and packing confirmed Fast RFQ response by sales engineer

Product Overview

Phoenix Contact QUINT-PS/1AC/24DC/10 Original Industrial Spare QUINT Compatible: Ensuring System Stability in Demanding Automation Environments

The Phoenix Contact QUINT-PS/1AC/24DC/10 is a high-performance, single-phase DIN rail power supply delivering a stable 24 VDC / 10 A output from a wide-range AC input. As a cornerstone of the renowned QUINT Power Series, this unit is engineered for continuous duty in industrial control panels, PLC enclosures, and distributed automation systems where power quality and uptime are non-negotiable. Sourcing an original replacement unit from a verified supplier is the single most effective action a maintenance team can take to eliminate unplanned downtime caused by power-related faults.

Whether you are managing a scheduled shutdown, responding to an emergency fault, or building a strategic spare-parts inventory, the QUINT-PS/1AC/24DC/10 delivers the electrical performance and long-term availability that industrial maintenance professionals depend on. Its SFB (Selective Fuse Breaking) technology, active power boost up to 200%, and integrated diagnostics make it a direct, plug-and-play replacement for aging or failed units in existing QUINT-based power distribution architectures.

Critical Technical Specs

Parameter Specification
Part Number / SKU QUINT-PS/1AC/24DC/10
Brand / Series Phoenix Contact / QUINT Power
Input Voltage 85–264 VAC (1-phase), 47–63 Hz
Output Voltage 24 VDC (adjustable 18–29.5 VDC)
Output Current 10 A nominal
Output Power 240 W
Power Boost Up to 200% (20 A) for 12 ms — SFB Technology
Efficiency ≥ 93%
Mounting DIN rail (EN 60715 TH35)
Protection Class IP20
Operating Temperature -25 °C to +70 °C
Certifications UL, cUL, CE, GL, DNV, ATEX Zone 2
Country of Origin Germany
Compatibility Direct replacement for QUINT-PS/1AC/24DC/10 in all QUINT-based panels
Maintenance Recommendation Inspect every 24 months or after sustained overload events
Warranty 12 Months — Tested before shipment

Preventive Maintenance Strategy

A power supply failure rarely occurs in isolation. In most industrial control cabinets, a degraded QUINT-PS/1AC/24DC/10 places stress on every downstream component it feeds. A disciplined preventive maintenance program treats the power supply as the anchor of a broader inspection cycle — and experienced maintenance engineers know that when a QUINT unit is pulled for replacement, it is the right moment to audit the entire power distribution chain.

Begin with the 24 VDC bus and terminal blocks. Loose or corroded connections on the output terminal strip are a leading cause of intermittent faults that are often misdiagnosed as PLC or I/O errors. While the panel is de-energized for the power supply swap, inspect and re-torque all terminal connections on the distribution rail. If your installation uses Phoenix Contact PTFIX or UT series terminal blocks, verify that no terminals show signs of heat discoloration — a reliable indicator of sustained overcurrent.

Next, evaluate the 24 VDC fuse modules protecting individual circuit branches. The QUINT-PS/1AC/24DC/10’s SFB boost technology is designed to blow downstream fuses selectively, but fuse modules that have operated near their rated current for extended periods should be replaced proactively. Phoenix Contact PTCB or UKK5 fuse terminal blocks are common companions in QUINT-based panels and deserve inspection during every power supply service interval.

The PLC CPU and I/O modules powered by this supply should also be checked. If the system runs on a Phoenix Contact ILC or RFC series controller, verify that the CPU’s internal diagnostics show no undervoltage events logged during the period the failing power supply was in service. Undervoltage events can corrupt program memory or cause I/O modules to latch in fault states. Similarly, inspect any digital input/output modules (DIO modules) in the same rack — these are sensitive to voltage transients that occur during power supply degradation.

For systems that include signal isolators or loop-powered transmitters on the 24 VDC rail, verify signal integrity after the power supply replacement. Devices such as MACX MCR signal conditioners or third-party 4–20 mA isolators can exhibit offset drift if they have been operating on a noisy or sagging supply. A brief loop calibration check after the power supply swap is a low-cost step that prevents future process deviations.

If the control cabinet includes a 24 VDC UPS buffer module — such as the Phoenix Contact QUINT-BUFFER or UPS-IQ series — inspect the buffer capacitors or battery module for end-of-life indicators. A power supply replacement is the ideal time to also replace a buffer module that has exceeded its service life, ensuring the entire energy storage and distribution chain is renewed simultaneously.

Finally, review the communication modules and fieldbus interfaces in the same enclosure. Profibus DP, PROFINET, or EtherNet/IP interface modules are sensitive to power quality. If the system uses Phoenix Contact FL SWITCH or RAD series wireless modules, confirm that their power inputs show stable voltage after the new QUINT unit is commissioned. A brief network diagnostic scan following the replacement will confirm that all nodes have re-established communication cleanly.

Strategic Replacement Solutions

The QUINT-PS/1AC/24DC/10 has been a production staple in Phoenix Contact’s power supply portfolio for over a decade, making it one of the most widely installed 24 VDC / 10 A DIN rail supplies in global industrial infrastructure. Many facilities are now operating original units that are approaching or have exceeded their 10-year design service life. Proactive replacement — rather than reactive replacement after failure — is the strategy that separates high-availability plants from those that suffer repeated unplanned outages.

An original replacement unit maintains 100% compatibility with existing wiring, DIN rail footprint, and panel documentation. There is no need to modify cable lengths, re-label terminals, or update electrical drawings. The replacement unit slots into the same position, connects to the same terminals, and resumes operation with identical output characteristics. This is the lowest-risk, lowest-labor replacement path available to maintenance teams managing aging QUINT-based infrastructure.

For facilities managing multiple control panels, we recommend establishing a minimum stock level of one spare QUINT-PS/1AC/24DC/10 per five installed units. This ratio balances inventory carrying cost against the risk of extended lead times during peak demand periods. Stocking a verified original spare eliminates the procurement delay that is often the longest component of mean-time-to-repair (MTTR) for power supply failures.

Each unit supplied by TOPNLMS is individually tested for output voltage accuracy, current limiting behavior, and SFB boost function prior to shipment. Units are shipped in original or equivalent protective packaging with full traceability documentation, supporting your incoming inspection and maintenance record requirements.

Support FAQ

Q1: Is this an original Phoenix Contact unit or a compatible replacement?
This is an original Phoenix Contact QUINT-PS/1AC/24DC/10. We do not supply clones, rebranded units, or third-party compatible alternatives. Every unit is sourced from authorized distribution channels and is fully traceable to Phoenix Contact manufacturing.

Q2: What does the 12-month warranty cover, and how is it validated?
The 12-month warranty covers manufacturing defects and functional failures under normal operating conditions. Each unit undergoes output voltage, current, and SFB boost testing before shipment. A test record is available upon request. Warranty claims are processed via direct RMA with TOPNLMS — no third-party authorization required.

Q3: Can this unit directly replace an older QUINT-PS/1AC/24DC/10 without panel modifications?
Yes. The replacement unit is dimensionally and electrically identical to all previous production runs of the QUINT-PS/1AC/24DC/10. DIN rail mounting, terminal pitch, output voltage adjustment range, and diagnostic LED positions are unchanged. No wiring modifications or documentation updates are required for a like-for-like swap.

Q4: What is the recommended inventory strategy for facilities with multiple QUINT units installed?
For facilities with 5 or more QUINT-PS/1AC/24DC/10 units installed, we recommend maintaining at least one verified spare on-site at all times. For critical production lines where a power supply failure would trigger a full line stop, a dedicated hot-spare policy — one spare per line — is the industry best practice. Contact our team for volume pricing on multi-unit spare stock orders.

Quick Inquiry