Molex DRL-DPM-BKF Replacement for DeviceNet Master Series
DRL-DPM-BKFMolex DRL-DPM-BKF DeviceNet Master Network Interface Module. Drop-in replacement & upgrade solution. Compatible wiring, protocol & rack. 12-month warranty.
Request availability, condition, lead time and export shipping details for SST-PB3-REM.
Send this exact part number, quantity and destination country. TOPNLMS will confirm availability, condition and export lead time before quotation.
The MOLEX SST-PB3-REM is an original PROFIBUS DP/DP linking device from the SST Series, engineered to bridge two independent PROFIBUS DP networks within a single control architecture. In industrial environments where distributed I/O, variable frequency drives, and remote field devices communicate across segmented PROFIBUS backbones, the SST-PB3-REM serves as the critical gateway that maintains data integrity and network timing across both segments. Sourced directly from authorized supply channels, this unit is fully tested, verified, and shipped with a 12-month warranty — making it a reliable choice for both emergency replacement and planned preventive maintenance stock.
For maintenance engineers managing aging PROFIBUS-based control systems, having a verified spare of the SST-PB3-REM on hand is not optional — it is a fundamental risk mitigation strategy. PROFIBUS DP/DP linking devices are single points of failure in multi-segment network topologies. When one fails, the downstream segment loses communication entirely, triggering cascading alarms, halting production lines, and forcing unplanned shutdowns. A pre-stocked, tested replacement unit reduces mean time to repair (MTTR) from hours to minutes.
| Parameter | Specification |
|---|---|
| Part Number | SST-PB3-REM |
| Manufacturer | MOLEX (formerly SST / Woodhead) |
| Series | SST PROFIBUS Interface Series |
| Function | PROFIBUS DP/DP Linking Device (Remote Module) |
| Network Protocol | PROFIBUS DP (EN 50170 / IEC 61158) |
| Baud Rate Support | 9.6 kbps – 12 Mbps (auto-detect) |
| Segments Bridged | 2 independent PROFIBUS DP segments |
| Max Slaves per Segment | Up to 125 DP slaves |
| Supply Voltage | 24 VDC (via backplane or external) |
| Operating Temperature | 0°C to +55°C |
| Storage Temperature | -25°C to +70°C |
| Protection Rating | IP20 (panel/cabinet mount) |
| Mounting | DIN rail / SST backplane |
| Compatibility | SST-PB3 base unit, PROFIBUS DP Class 1 & Class 2 masters |
| Certifications | CE, UL (refer to product datasheet) |
| Condition | Original, new or refurbished-tested |
| Pre-shipment Testing | Full functional communication test performed |
| Origin | USA |
| Warranty | 12 Months from shipment date |
A PROFIBUS DP/DP linking device like the SST-PB3-REM does not operate in isolation. It is embedded within a broader control cabinet ecosystem, and its reliable operation depends on the health of surrounding components. When scheduling a planned maintenance window or responding to a network fault, experienced maintenance teams know to inspect the entire communication chain — not just the linking device itself.
Begin with PROFIBUS cable and DB9 connector integrity: degraded connectors or improperly terminated bus cables are among the most common causes of intermittent DP communication errors mistakenly attributed to the linking device. Inspect termination resistors at both ends of each segment and verify bus topology compliance. At the same time, check the SST-PB3 base unit — the backplane module that the SST-PB3-REM plugs into — for signs of corrosion, bent pins, or firmware version mismatches that could prevent proper handshake with the remote module.
Power supply stability is equally critical. The 24 VDC DIN rail power supply feeding the SST backplane should be load-tested and its output ripple verified; an unstable supply voltage is a frequent root cause of unexplained PROFIBUS resets. If the control cabinet also houses a PROFIBUS DP master communication card — such as an SST-PB3-CLX for ControlLogix or a Siemens CP 342-5 for S7-300 — inspect its firmware revision and verify that its GSD file configuration matches the current network topology, including the SST-PB3-REM’s slave address assignment.
For facilities running mixed automation architectures, the SST-PB3-REM often sits between a Rockwell Automation ControlLogix or CompactLogix PLC on one segment and a field device network — VFDs, distributed I/O racks, or pneumatic valve islands — on the other. During inspection, verify that remote I/O modules on the downstream segment (such as Siemens ET 200S distributed I/O or Phoenix Contact Inline I/O modules) are responding correctly and that their diagnostic LEDs show no fault states. A single unresponsive I/O module can cause the linking device to report segment errors even when the SST-PB3-REM itself is fully functional.
Proactive spare parts planning for a PROFIBUS cabinet should also include PROFIBUS repeaters for long cable runs exceeding segment length limits, optical fiber PROFIBUS converters for electrically noisy environments such as motor control centers, and signal isolators for segments crossing ground potential differences. Maintain a spare 24 VDC DIN rail power supply rated for the cabinet’s full load, as well as spare fuse modules protecting the PROFIBUS segment power rails. For cabinets with HMI operator panels communicating over PROFIBUS, keep a record of the HMI project file version and verify that the panel’s PROFIBUS address does not conflict with the SST-PB3-REM’s configured slave address. Additionally, PROFIBUS diagnostic tools such as a bus monitor or protocol analyzer should be part of every maintenance team’s toolkit to quickly isolate faults to the correct segment or device.
The SST-PB3-REM was originally manufactured under the SST (Spectrum Systems Technology) brand before MOLEX acquired the product line. Many facilities still operate legacy SST-branded units that are no longer available through standard distribution channels. The MOLEX SST-PB3-REM offered here is the direct OEM-equivalent replacement, maintaining full backward compatibility with existing SST-PB3 base units and requiring no firmware changes or GSD file updates in the PROFIBUS master configuration.
For plants running older Siemens S5 or early S7-300 PROFIBUS networks that were extended using SST linking devices, replacing a failed SST-PB3-REM with this unit restores full network segmentation capability without requiring a costly system redesign or migration to a newer communication standard. This is particularly valuable in industries with long equipment lifecycles — petrochemical, power generation, water treatment, and heavy manufacturing — where control system replacement is deferred for 10–20 years beyond the original design life.
Compared to sourcing a new PROFIBUS gateway from current-generation vendors, the SST-PB3-REM replacement path eliminates re-engineering costs, avoids PLC program modifications, and preserves the existing network topology. Maintenance teams can execute the swap during a scheduled shutdown window with minimal risk, using the same GSD file and slave address configuration already validated in the master PLC project. For multi-site operations managing dozens of PROFIBUS segments, procuring a buffer stock of SST-PB3-REM units ensures consistent spare availability across all facilities without exposure to spot-market lead times or price volatility.
Q1: Is this SST-PB3-REM an original MOLEX unit or a third-party compatible replacement?
This is an original MOLEX SST-PB3-REM unit — either new old stock (NOS) or a fully refurbished and tested original. It is not a third-party clone or compatible substitute. All units undergo full functional communication testing prior to shipment and are covered by a 12-month warranty from the date of delivery.
Q2: Will this unit work with my existing SST-PB3 base module without any configuration changes?
Yes. The SST-PB3-REM is a plug-in remote module for the SST-PB3 base unit and is designed for direct replacement without firmware updates or GSD file modifications, provided your existing base unit firmware is compatible. We recommend verifying the base unit firmware revision against the SST-PB3-REM datasheet before installation.
Q3: What is your pre-shipment testing process and how is the unit packaged?
Every SST-PB3-REM unit is powered up and subjected to a full functional communication test before shipment. Units are packaged in anti-static ESD bags with foam padding inside a rigid carton to prevent transit damage. A test report is available upon request for quality-critical applications.
Q4: How should I manage my spare parts inventory for PROFIBUS linking devices?
For production-critical PROFIBUS networks, we recommend maintaining a minimum of one SST-PB3-REM spare per active base unit installed. For facilities with three or more SST-PB3 base units, a 1:3 spare ratio is a common industry practice. Given the discontinuation risk for legacy SST Series components, procuring a buffer stock of 2–3 units is advisable for long-term system support without exposure to spot-market price volatility.
Click Quote This Model and the Part Number field will auto-fill with SST-PB3-REM.