MKS 902-1112 Original Industrial Spare 902 Series Compatible
902-1112MKS 902-1112 original industrial spare. 902 Series piezo vacuum transducer, direct replacement, system-compatible. 12-month warranty. Ships globally from TOPNLMS.
Request availability, condition, lead time and export shipping details for 722B11TCD2FA DUPLICATOR RAS16 DIAPHRAGM PUMP A 10 TTT.
Send this exact part number, quantity and destination country. TOPNLMS will confirm availability, condition and export lead time before quotation.
Upgrading or replacing a failed MKS 722B11TCD2FA Baratron Capacitance Manometer does not have to mean extended downtime or costly system redesigns. The 722B11TCD2FA is a precision absolute pressure transducer from MKS Instruments’ industry-standard 722B Baratron series, rated for a 10 Torr full-scale range and widely deployed in semiconductor process chambers, thin-film deposition systems, chemical vapor deposition (CVD) reactors, and high-vacuum research environments. TOPNLMS supplies verified replacement and upgrade units for this model, enabling engineers and procurement teams to restore system performance with minimal disruption to existing wiring, signal conditioning, and process control architecture.
| Parameter | Original: MKS 722B11TCD2FA | Replacement Unit |
|---|---|---|
| Measurement Type | Absolute Pressure | Absolute Pressure |
| Full-Scale Range | 10 Torr | 10 Torr |
| Sensor Technology | Capacitance Diaphragm (Baratron) | Capacitance Diaphragm |
| Output Signal | 0–10 VDC (linear) | 0–10 VDC (linear) |
| Electrical Connector | 15-pin D-sub (standard 722B pinout) | 15-pin D-sub (compatible) |
| Process Connection | 1/4″ VCR / KF16 (model-dependent) | Matched to original spec |
| Operating Temperature | 0–50 °C (ambient) | 0–50 °C |
| Power Supply | ±15 VDC | ±15 VDC |
| Communication Protocol | Analog (0–10 V) | Analog (0–10 V) |
| Mounting / Form Factor | Standard 722B body | Direct form-fit replacement |
| Replacement Recommendation | Direct drop-in; no wiring or software changes required in most installations | |
| Warranty | — | 12-Month Warranty (TOPNLMS) |
A successful 722B11TCD2FA replacement is rarely a single-component swap. In practice, engineers migrating from aging or discontinued vacuum measurement setups often address several interconnected subsystems simultaneously. The 722B series transducer interfaces directly with MKS Type 670 and Type 600 series signal conditioner/power supply units, which provide the regulated ±15 VDC excitation and house the analog readout circuitry. If the existing conditioner is also end-of-life, sourcing a compatible MKS 670B or 670C signal conditioner alongside the 722B11TCD2FA replacement ensures the entire measurement chain is refreshed without altering the downstream 0–10 V analog input to the process controller or PLC.
In systems where the 722B feeds into a multi-channel vacuum gauge controller — such as the MKS 937B or PDR900 series — the analog signal wiring and channel assignment remain unchanged, preserving calibration offsets and alarm setpoints already programmed into the controller. For installations using an MKS 247D or 647C mass flow controller readout, the pressure transducer output is typically used as a process interlock; the replacement unit’s identical output range means no reconfiguration of interlock thresholds is required.
Where the 722B11TCD2FA is installed in a load-lock or transfer chamber alongside a Pirani gauge (such as the MKS 925 Micro-Pirani) for wide-range pressure monitoring, both sensors can be replaced or serviced independently. The Baratron’s high-accuracy absolute measurement in the 1 mTorr–10 Torr range complements the Pirani’s broader but less precise coverage, and the two-sensor architecture remains intact after the 722B swap.
For facilities running older CVD or etch tools with legacy wiring harnesses, the 15-pin D-sub connector on the replacement 722B11TCD2FA mates directly to existing cable assemblies. No re-pinning or adapter boards are needed. If the original cable shows wear, standard MKS-compatible 722B interface cables are available and can be supplied together with the transducer to complete the retrofit in a single procurement action.
In rack-mounted control cabinets where space is constrained, the 722B body’s compact cylindrical form factor fits existing panel cutouts and bracket mounts without modification. Engineers retrofitting older Varian, Applied Materials, or Lam Research process tools will find the physical envelope of the replacement unit consistent with the original installation drawings. Where the system also includes a throttle valve controller (such as the MKS 253B or 653B series) using the 722B output as a pressure feedback signal, the analog interface remains fully compatible — no PID re-tuning is required after transducer replacement.
Q: Will the replacement 722B11TCD2FA require re-zeroing or recalibration after installation?
A: A zero-point verification is recommended after installation, as with any capacitance manometer replacement. Most MKS signal conditioners (670 series) provide a front-panel zero adjustment. Full-scale calibration is factory-set and traceable to NIST standards; field recalibration is typically not required unless process accuracy demands it.
Q: Is the wiring pinout identical to the original unit?
A: Yes. The replacement unit follows the standard MKS 722B 15-pin D-sub pinout. Power (±15 VDC), signal output (0–10 VDC), and ground assignments are unchanged. Existing cable assemblies can be reconnected without modification.
Q: Does the replacement affect PLC or DCS programming?
A: No software or ladder logic changes are required. The analog output range (0–10 VDC = 0–10 Torr) is identical, so all scaling, alarm, and interlock parameters in the PLC or DCS remain valid.
Q: What is the process connection compatibility?
A: The 722B11TCD2FA uses a standard vacuum process fitting (VCR or KF, per the original configuration). The replacement unit matches the original process connection type. Confirm your existing fitting style before ordering if your installation has been modified.
Q: How long does installation take?
A: A trained technician can complete the mechanical swap, electrical reconnection, and zero verification in under 30 minutes on most tools, minimizing scheduled maintenance windows.
Q: Can this unit replace other 722B variants?
A: The 722B platform shares a common form factor and electrical interface across many range and output configurations. Cross-compatibility depends on the full-scale range and output option of the installed unit. Contact TOPNLMS with your existing model number for a compatibility assessment.
Every MKS 722B11TCD2FA replacement unit supplied by TOPNLMS is covered by a 12-month warranty from the date of shipment. Prior to dispatch, each unit undergoes functional verification including power-on testing, output linearity check, and zero-point confirmation. Units are packaged in anti-static, shock-resistant materials consistent with precision instrument handling standards.
In the event of a warranty claim, TOPNLMS provides direct replacement support with a target response time of 1–2 business days. Defective units are assessed and replaced or refunded at no additional cost to the buyer. Our after-sales team is reachable at [email protected] or +86 18359293191 for technical pre-sales questions, compatibility verification, and post-shipment support.
For procurement teams managing planned maintenance schedules or emergency breakdowns, TOPNLMS maintains ready stock of high-demand MKS Baratron series components to support fast turnaround. Standard shipping from Xiamen is available with express options for urgent requirements. A proforma invoice and packing list are provided with every shipment to support customs clearance and internal asset management.
Click Quote This Model and the Part Number field will auto-fill with 722B11TCD2FA DUPLICATOR RAS16 DIAPHRAGM PUMP A 10 TTT.