GE IC698CMX016-ED Original Industrial Spare RX7i Compatible
IC698CMX016-EDGE IC698CMX016-ED original PACSystems RX7i multi-protocol communication module. Genuine industrial spare, RX7i compatible, 12-month warranty, fast shipping.
Request availability, condition, lead time and export shipping details for IC695PNC001-AK.
Send this exact part number, quantity and destination country. TOPNLMS will confirm availability, condition and export lead time before quotation.
The GE Fanuc IC695PNC001-AK is a PROFINET IO Controller module designed for the PACSystems RX3i platform — one of the most widely deployed programmable automation controller (PAC) architectures in discrete manufacturing, process control, and utility automation. As a genuine original spare, the IC695PNC001-AK enables maintenance teams to restore PROFINET network communication and IO device management without re-engineering the control architecture, making it a critical asset in any industrial spare parts inventory.
In high-availability production environments, unplanned downtime caused by a failed PROFINET IO controller can cascade across entire production lines. The IC695PNC001-AK slots directly into the RX3i Universal Backplane (IC695CHS007 or IC695CHS012), restoring PROFINET IO master functionality within the existing CPU configuration. Whether you are managing a food processing facility, an automotive assembly line, or a water treatment plant, having this module on the shelf eliminates the lead-time risk that comes with sourcing critical controllers during an emergency shutdown.
| Parameter | Specification |
|---|---|
| Part Number | IC695PNC001-AK |
| Series | PACSystems RX3i |
| Module Type | PROFINET IO Controller |
| Network Protocol | PROFINET IO (IRT / RT) |
| Max IO Devices | Up to 128 PROFINET IO devices |
| Ethernet Ports | 2 × RJ45 (integrated switch) |
| Communication Speed | 10/100 Mbps |
| Backplane Compatibility | IC695CHS007, IC695CHS012 (RX3i Universal Backplane) |
| Power Consumption | Supplied via RX3i backplane |
| Operating Temperature | 0°C to 60°C |
| Storage Temperature | -40°C to 85°C |
| Humidity | 5% to 95% non-condensing |
| Certifications | CE, UL, cUL |
| Country of Origin | United States |
| Weight | Approx. 400 g |
| Warranty | 12 Months |
| Condition | Original, tested before shipment |
A PROFINET IO controller failure rarely occurs in isolation. When performing scheduled maintenance or responding to a network fault on an RX3i system, experienced maintenance engineers treat the IC695PNC001-AK replacement as an opportunity to audit the entire control cabinet. The RX3i CPU module — typically an IC695CPU310 or IC695CPU320 — should be inspected for firmware currency and battery backup status. A degraded CPU battery can cause configuration loss during a power cycle, compounding the impact of a PROFINET fault.
The RX3i power supply module (such as the IC695PSA040 or IC695PSD040) should be load-tested during the same maintenance window. An aging power supply operating near its rated capacity is a common root cause of intermittent module resets that are often misdiagnosed as PROFINET controller failures. Replacing the IC695PNC001-AK without verifying power supply health risks repeat failures within weeks.
On the PROFINET network side, inspect the managed Ethernet switch connecting the IC695PNC001-AK to downstream IO devices. Switches with degraded ports or misconfigured VLANs can prevent IO device discovery even after a successful controller replacement. At the same time, review the PROFINET IO device modules in the field — remote IO heads such as the IC694MDL754 discrete output module or IC694ALG220 analog input module should be checked for communication timeout errors logged in the CPU diagnostics buffer.
For RX3i systems with serial communication requirements, the IC695CMM002 serial communications module should be verified for port integrity and baud rate configuration. In mixed-protocol environments where PROFINET coexists with Modbus RTU or DNP3, a faulty serial module can create diagnostic noise that masks the true source of a network alarm. Similarly, the IC695ETM001 Ethernet module — if present for EGD or SRTP communications — should be pinged and its connection table validated.
Analog signal integrity is another area to audit during a PROFINET maintenance event. Signal isolators on 4–20 mA loops feeding RX3i analog input modules can drift over time, producing out-of-range values that trigger false process alarms. Replacing or recalibrating these isolators during the same planned outage maximizes the value of the maintenance window. Terminal blocks and field wiring terminations in the control cabinet should also be torque-checked, as loose connections are a leading cause of intermittent IO faults that are difficult to reproduce under normal operating conditions.
Finally, if the facility operates HMI panels communicating with the RX3i CPU via PROFINET or Ethernet, verify that the HMI project is backed up and that the communication driver configuration matches the updated IP addressing scheme after the IC695PNC001-AK replacement. An HMI that loses its CPU connection during a controller swap can trigger operator alarms and complicate the restart sequence.
The IC695PNC001-AK is a direct replacement for earlier PROFINET controller revisions within the PACSystems RX3i family. Facilities running legacy GE Series 90-30 or Series 90-70 PLC architectures that are being migrated to RX3i will find the IC695PNC001-AK essential for establishing PROFINET IO connectivity without replacing field wiring or IO device infrastructure. The module supports GSDML-based device integration, meaning existing PROFINET IO device configurations can be imported directly into the PAC Machine Edition (PME) programming environment, dramatically reducing commissioning time.
For plants managing aging RX3i systems beyond their original design life, stocking the IC695PNC001-AK as a cold spare eliminates the risk of extended lead times from the original equipment manufacturer. Original spare modules sourced through authorized distribution channels maintain full firmware compatibility and are eligible for GE Vernova technical support, unlike refurbished or counterfeit alternatives that may introduce latent reliability risks.
The IC695PNC001-AK also supports system expansion scenarios where additional PROFINET IO devices — such as distributed IO racks, variable frequency drives with PROFINET adapters, or smart field instruments — need to be integrated into an existing RX3i network without replacing the CPU. This makes it a cost-effective path to incremental automation upgrades in facilities where a full control system replacement is not yet justified.
Q1: Is the IC695PNC001-AK compatible with all PACSystems RX3i CPU revisions?
The IC695PNC001-AK is compatible with PACSystems RX3i CPUs including the IC695CPU310, IC695CPU320, and IC695CPE302, provided the CPU firmware meets the minimum version required for PROFINET IO controller support. Compatibility should be verified against the GE PACSystems RX3i System Manual (GFK-2314) before installation. We recommend confirming your CPU firmware revision prior to ordering.
Q2: What testing is performed before shipment?
Every IC695PNC001-AK unit is powered on and functionally tested prior to shipment. Testing includes backplane communication verification, Ethernet port link integrity, and module self-diagnostic checks. A test report is available upon request. All units are shipped in anti-static packaging with protective foam inserts to prevent transit damage.
Q3: What does the 12-month warranty cover?
The 12-month warranty covers manufacturing defects and functional failures under normal operating conditions. It does not cover damage resulting from incorrect installation, overvoltage events, or physical mishandling. Warranty claims are processed within 5 business days of receipt of the returned unit. Replacement or repair is provided at no additional cost during the warranty period.
Q4: How do I verify compatibility before replacing the module in the field?
Before replacing the IC695PNC001-AK in a live system, record the existing module’s firmware version and PROFINET device configuration from the PAC Machine Edition project. Ensure the replacement module’s hardware revision (AK) matches or is forward-compatible with your system’s configuration. Power down the RX3i rack before removal, follow GE’s hot-swap guidelines if applicable to your backplane revision, and perform a full IO device scan after installation to confirm all PROFINET devices are recognized before resuming production.
Click Quote This Model and the Part Number field will auto-fill with IC695PNC001-AK.