GE IC698CMX016-ED Original Industrial Spare RX7i Compatible
IC698CMX016-EDGE IC698CMX016-ED original PACSystems RX7i multi-protocol communication module. Genuine industrial spare, RX7i compatible, 12-month warranty, fast shipping.
Request availability, condition, lead time and export shipping details for IC695PNC001CA.
Send this exact part number, quantity and destination country. TOPNLMS will confirm availability, condition and export lead time before quotation.
The GE IC695PNC001CA is a PROFINET IO Controller module designed for the GE PACSystems RX3i platform. As legacy automation systems age and original GE Fanuc components reach end-of-life or become increasingly difficult to source, plant engineers and procurement teams face mounting pressure to maintain uptime while managing obsolescence risk. TOPNLMS supplies the IC695PNC001CA as a direct replacement and upgrade solution, enabling facilities to restore full PROFINET IO communication capability without redesigning their existing control architecture.
The IC695PNC001CA slots directly into the Universal Backplane of the PACSystems RX3i rack — compatible with the IC695CHS007, IC695CHS012, and IC695CHS016 chassis variants — and requires no additional mounting hardware or backplane modification. Power is drawn from the rack’s shared power bus, supplied by modules such as the IC695PSA040 or IC695PSD040 power supply, both of which remain fully compatible with this controller module. Engineers replacing a failed or obsolete PROFINET IO controller can complete the physical swap in under 30 minutes with standard tools.
From a communications standpoint, the IC695PNC001CA supports PROFINET IO RT (Real-Time) and IRT (Isochronous Real-Time) protocols, maintaining full compatibility with existing PROFINET device networks including remote I/O stations, distributed drives, and field instruments already wired to the plant network. Facilities that have deployed GE VersaMax PROFINET Scanner modules (IC200PNS001 or IC200PNS002) as remote I/O adapters will find that the IC695PNC001CA continues to manage these devices without requiring re-parameterization of the remote station GSD files, provided the replacement module is configured with the same PROFINET device name and IP address as the original.
For sites running Proficy Machine Edition (PME) or Proficy Process Systems as the programming environment, the IC695PNC001CA is fully supported under the existing hardware configuration. The PROFINET IO topology — including device names, slot assignments, and I/O mapping — is stored in the CPU project (typically an IC695CPE305, IC695CPE310, or IC695CPE400 controller), not in the PROFINET IO controller module itself. This means that after physical replacement, the engineer simply downloads the existing project to the CPU and the IC695PNC001CA resumes normal IO scanning without reprogramming the PROFINET network from scratch.
Wiring compatibility is a key concern during any module replacement. The IC695PNC001CA connects to the PROFINET network via a standard RJ45 Ethernet port (100 Mbps, full duplex), using the same Cat5e or Cat6 cabling already installed in the control cabinet. There are no proprietary connectors or special cable assemblies required. For facilities using managed Ethernet switches within the PROFINET ring or line topology — such as Scalance or Hirschmann switches already integrated into the network — the IC695PNC001CA operates transparently within the existing switch configuration.
In multi-rack or distributed control architectures, the IC695PNC001CA works alongside other RX3i communication modules such as the IC695ETM001 Ethernet module and IC695CMM002 serial communication module, sharing the backplane without conflict. Sites that also operate IC695ALG600 analog input modules, IC695MDL654 discrete output modules, or IC695MDL752 discrete input modules on the same rack will experience no interference from the PROFINET IO controller module during normal operation.
For facilities upgrading from older GE Series 90-30 or Series 90-70 PROFIBUS-based systems to PROFINET, the IC695PNC001CA represents the recommended migration path within the PACSystems RX3i ecosystem. The transition from PROFIBUS DP to PROFINET IO typically involves replacing the communications module, updating the hardware configuration in PME, and re-mapping I/O addresses — a process that TOPNLMS technical support can assist with during pre-shipment consultation.
All IC695PNC001CA units supplied by TOPNLMS are sourced from verified supply channels, inspected for firmware version compatibility, and tested for communication functionality prior to dispatch. Units are shipped from Xiamen, China, with full export documentation, and are available for express international delivery to minimize plant downtime during emergency replacement scenarios.
| Parameter | IC695PNC001CA (Replacement) | Typical Legacy / Predecessor |
|---|---|---|
| Platform | PACSystems RX3i | Series 90-30 / Series 90-70 |
| Communication Protocol | PROFINET IO RT / IRT | PROFIBUS DP / Ethernet Global Data |
| Physical Interface | RJ45 (100 Mbps, Full Duplex) | DB9 / Proprietary PROFIBUS Connector |
| Rack Compatibility | IC695CHS007 / CHS012 / CHS016 | IC693CHS391 / IC697CHS750 (not compatible) |
| Power Supply Compatibility | IC695PSA040 / IC695PSD040 | IC693PWR321 / IC697PWR748 (separate) |
| Programming Software | Proficy Machine Edition (PME) | Logicmaster 90 / Control |
| IO Device Support | Up to 128 PROFINET IO devices | Up to 125 PROFIBUS DP slaves |
| Installation | Direct backplane insertion, no tools | Screw-terminal or DIN rail (varies) |
| Firmware Update | Via PME / Ethernet | Via serial port / proprietary tool |
| Warranty (TOPNLMS Supply) | 12 Months | N/A (end-of-life / no support) |
A successful migration to or around the IC695PNC001CA typically involves coordinating several related components within the PACSystems RX3i ecosystem. The CPU module — most commonly an IC695CPE305 or IC695CPE400 — holds the PROFINET IO configuration and must be online during commissioning to push device parameters to the IC695PNC001CA. The rack chassis (IC695CHS012 is the most common 12-slot variant) must be verified for backplane integrity before inserting the replacement module, particularly in high-vibration environments.
On the power side, the IC695PSA040 (120/240 VAC input) or IC695PSD040 (24 VDC input) power supply modules should be inspected and replaced if they show signs of aging, as power instability is a leading cause of PROFINET communication faults. For remote I/O expansion, the IC200PNS001 VersaMax PROFINET Scanner continues to serve as the standard remote adapter, connecting field-level I/O modules to the PROFINET network managed by the IC695PNC001CA.
Discrete I/O modules such as the IC695MDL654 (32-point 24 VDC output) and IC695MDL752 (32-point 24 VDC input) are commonly installed in the same rack and are unaffected by the PROFINET controller replacement. Analog signal conditioning may involve the IC695ALG600 analog input module, which communicates over the backplane rather than PROFINET and therefore requires no reconfiguration during this upgrade. For facilities requiring serial legacy device integration alongside PROFINET, the IC695CMM002 serial communications module can coexist in the same rack, supporting Modbus RTU or SNP protocols independently of the PROFINET IO controller.
Where cabinet space is constrained, the compact form factor of the IC695PNC001CA — occupying a single backplane slot — makes it straightforward to integrate into existing panel layouts without requiring additional DIN rail space or external signal isolators. For sites that require galvanic isolation between the PROFINET network and field wiring, external signal isolators or surge protection devices can be added at the cabinet entry point without any modification to the IC695PNC001CA itself.
Q: Can I replace a failed IC695PNC001 (without the CA suffix) with an IC695PNC001CA?
A: Yes. The CA suffix denotes a catalog revision with no functional difference for most applications. The hardware configuration in PME may show a minor revision update prompt, which can be accepted without impact to the PROFINET IO device list or I/O mapping.
Q: Do I need to reconfigure PROFINET device names after replacement?
A: No. PROFINET device names and IP addresses are stored in the CPU project, not in the IC695PNC001CA module. After downloading the existing project to the CPU, the replacement module will automatically assign device names to connected IO devices during the startup sequence.
Q: Is the IC695PNC001CA compatible with third-party PROFINET IO devices?
A: Yes, provided the third-party device has a valid GSD/GSDML file and supports PROFINET IO RT. IRT compatibility depends on the specific device and network topology.
Q: What is the physical installation procedure?
A: Power down the rack (or use hot-swap procedures if supported by your CPU firmware version), remove the failed module, insert the IC695PNC001CA into the same backplane slot, restore power, and download the CPU project. Total installation time is typically under 30 minutes for experienced engineers.
Q: Can the IC695PNC001CA be used in a redundant CPU configuration?
A: The IC695PNC001CA is designed for standard (non-redundant) RX3i configurations. For redundant CPU systems, consult GE documentation for the appropriate PROFINET IO controller variant.
Q: What if my existing PROFINET network uses a ring topology with MRP?
A: The IC695PNC001CA supports Media Redundancy Protocol (MRP) client mode. Verify that your managed Ethernet switches are configured as MRP managers and that the ring topology is intact before commissioning.
Every IC695PNC001CA unit supplied by TOPNLMS is covered by a 12-month warranty from the date of shipment. Prior to dispatch, each unit undergoes a functional inspection including power-on verification, firmware version check, and communication port integrity testing. Units that do not pass inspection are not shipped.
In the event of a warranty claim, TOPNLMS provides a replacement unit or full refund within the warranty period, subject to inspection of the returned module. Our technical team is available via email and phone to assist with installation questions, compatibility verification, and commissioning support before and after delivery.
For urgent replacement requirements, express shipping from Xiamen is available to most international destinations, with typical transit times of 3–7 business days to Europe, North America, and Southeast Asia. All shipments include commercial invoice, packing list, and country-of-origin documentation to support customs clearance.
Procurement teams can request a formal quotation, lead time confirmation, and certificate of conformance by contacting TOPNLMS directly. Bulk orders and standing purchase agreements are supported for MRO and spare parts programs.
Click Quote This Model and the Part Number field will auto-fill with IC695PNC001CA.