Language English USD Currency
Call WhatsApp RFQ
Bosch Rexroth Industrial Automation Part

Bosch Rexroth VDP40.3DIN-D1-NN-CG IndraControl V Upgrade

Request availability, condition, lead time and export shipping details for VDP40.3DIN-D1-NN-CG.

Bosch Rexroth

VDP40.3DIN-D1-NN-CG

Send this exact part number, quantity and destination country. TOPNLMS will confirm availability, condition and export lead time before quotation.

Part NumberVDP40.3DIN-D1-NN-CG
CategoryHMI
ConditionAvailability Check
Lead TimeRFQ Confirmation
SeriesIndraControl
ShippingExport packing available
Model checked before quotation Condition and packing confirmed Fast RFQ response by sales engineer

Product Overview

Bosch Rexroth VDP40.3DIN-D1-NN-CG IndraControl V Upgrade: Seamless Transition from Legacy HMI Systems

The Bosch Rexroth VDP40.3DIN-D1-NN-CG is a DIN-rail mounted operator panel belonging to the IndraControl V series — one of Rexroth’s most widely deployed human-machine interface platforms in motion control, hydraulic press, and machine tool applications. As legacy IndraControl V panels reach end-of-life or become increasingly difficult to source, plant engineers and maintenance teams face mounting pressure to identify a compatible, drop-in replacement that preserves existing wiring infrastructure, SERCOS or PROFIBUS communication topology, and IndraWorks engineering project files.

TOPNLMS stocks verified VDP40.3DIN-D1-NN-CG units sourced directly from authorized distribution channels. Each unit undergoes pre-shipment functional verification before dispatch from our Xiamen warehouse. Whether you are executing a like-for-like panel swap on a single machine or planning a phased migration across a multi-axis IndraControl V installation, our team provides the technical documentation and procurement support to keep your project on schedule.

Compatibility Comparison Table

Parameter Legacy / Outgoing Model VDP40.3DIN-D1-NN-CG (Replacement)
Series IndraControl V (earlier VDP40 variants) IndraControl V — VDP40.3DIN generation
Mounting Style Panel cutout / front-of-door DIN-rail (35 mm TS 35) — direct rail snap-in
Display 4-line text LCD or early graphic panel Graphic LCD, backlit, suitable for IndraWorks HMI runtime
Communication Interface RS-232 / RS-485 serial to controller Serial interface compatible with IndraControl L/M/XM controllers
Power Supply 24 V DC (controller-supplied) 24 V DC — same supply rail, no additional PSU required
Wiring Connector Proprietary Rexroth multi-pin connector Compatible connector pinout — existing cable harness reusable
Engineering Software IndraWorks 9.x / 12.x / 13.x Compatible with IndraWorks 13 and later; project migration supported
Physical Dimensions Varies by prior VDP40 sub-type Standard DIN-rail footprint — fits existing control cabinet rail space
Replacement Recommendation Discontinued / EOL VDP40 variants Direct replacement; retain existing wiring and project structure
Warranty 12-Month Warranty from TOPNLMS shipment date

Seamless Upgrade Solutions

A successful IndraControl V panel migration rarely involves the HMI alone. In practice, the VDP40.3DIN-D1-NN-CG replacement is most often executed alongside a broader system refresh that touches several interconnected components. When the operator panel is swapped, engineers typically audit the IndraControl L40 or IndraControl XM22 motion controller that the VDP40 communicates with, confirming firmware compatibility and verifying that the controller’s serial port parameters match the replacement panel’s baud rate and protocol settings.

In multi-axis press or injection-molding installations, the VDP40 panel often shares a control cabinet with IndraDrive C or IndraDrive M servo drive modules. During a panel replacement, it is good practice to inspect the CSB01 or CSE02 drive control sections for firmware currency, since an updated HMI runtime may expose new diagnostic parameters that older drive firmware cannot report. Similarly, the HCS02 or HCS03 power sections should be checked for capacitor condition if the machine has been in service for more than seven years.

Communication integrity is another critical checkpoint. Many IndraControl V installations route axis data and I/O status over SERCOS III fiber-optic rings. If the replacement panel project references SERCOS ring topology, the CSB01.1N-SE3-ENS-NNN-NN-S-NN-FW SERCOS interface card in the drive must be confirmed present and functional. For installations using PROFIBUS-DP instead, the CSB01.1N-PB3 communication option card and its GSD file version should be validated against the new IndraWorks project before commissioning.

On the I/O side, DIN-rail-mounted Rexroth Inline I/O modules — such as the R-IB IL 24 DI 8/HD-PAC digital input module or the R-IB IL 24 DO 8/HD-PAC digital output module — are frequently present in the same cabinet. These modules communicate over the Inline bus and are unaffected by the HMI swap, but their diagnostic status should be reviewed in the IndraWorks I/O configuration after the new panel is brought online to confirm that all field signals are correctly mapped.

Power distribution within the cabinet should also be reviewed. The Rexroth HNF01 mains filter and HNL01 line choke, if present, condition the AC supply feeding the IndraDrive power sections. Replacing the VDP40 panel is an opportune moment to verify that the 24 V DC PELV supply — often a Rexroth PSI6200 or equivalent Murr/Phoenix Contact unit — is within voltage tolerance, since an under-voltage condition can cause intermittent panel resets that are difficult to diagnose after reassembly.

Finally, if the site uses a Rexroth BTA20 or BTA21 programming and diagnostic adapter for serial connection between a laptop and the IndraControl L controller, confirm that the adapter driver is installed on the commissioning notebook before the panel swap. This ensures that IndraWorks can establish a live connection to download the updated HMI project and verify axis parameterization without delay.

Retrofit Guidance FAQ

Q: Can I reuse the existing wiring harness when replacing the VDP40.3DIN-D1-NN-CG?
A: In most cases, yes. The VDP40.3DIN-D1-NN-CG uses the same connector pinout as earlier DIN-rail VDP40 variants. Verify the cable part number against the Rexroth wiring diagram for your specific machine; if the connector matches, the harness can be transferred directly without re-termination.

Q: Do I need to modify my IndraWorks project after installing the replacement panel?
A: If the replacement unit is the same hardware generation (VDP40.3DIN), the existing IndraWorks HMI project should load without modification. If you are migrating from an older VDP40.2 or VDP40.1 variant, a project conversion step in IndraWorks may be required to update screen resolution and font references.

Q: Is the VDP40.3DIN-D1-NN-CG compatible with PROFIBUS and SERCOS III simultaneously?
A: The VDP40 panel itself communicates with the IndraControl L/M/XM controller via a dedicated serial link, independent of the fieldbus topology. PROFIBUS-DP and SERCOS III are handled by the controller and drive communication option cards, not by the HMI panel. The panel replacement therefore does not affect fieldbus configuration.

Q: What is the physical installation space requirement for DIN-rail mounting?
A: The VDP40.3DIN snaps onto a standard 35 mm DIN rail (TS 35 per EN 60715). Ensure at least 50 mm of clearance above and below the unit for ventilation and cable routing. The unit depth behind the rail is approximately 60 mm — verify cabinet depth before installation.

Q: How do I handle the transition if my original panel is completely non-functional?
A: If the original panel cannot power on, the IndraControl L controller will continue to run the motion program autonomously (axes remain operational). The HMI is not in the safety-critical control path for most standard configurations. You can install and power the replacement panel while the machine is in a safe stopped state, then download the HMI project via IndraWorks without requiring a full system restart.

Q: What communication protocol does the VDP40.3DIN use to connect to the controller?
A: The VDP40.3DIN communicates with the IndraControl L or XM controller via a proprietary Rexroth serial protocol over the panel port (typically labeled X8 or XS on the controller). This is not a standard RS-232 or Ethernet connection — use only the Rexroth-specified cable assembly for this link.

Warranty Assurance

Every VDP40.3DIN-D1-NN-CG unit shipped by TOPNLMS is covered by a 12-month warranty from the date of shipment. Prior to dispatch, each unit is powered on and subjected to a functional verification routine that confirms display operation, keypad response, and communication port integrity. Units that do not pass this check are quarantined and not offered for sale.

In the event of a warranty claim, TOPNLMS will arrange a replacement unit shipment within 3 business days of receiving the defective item and confirming the fault. Return freight for warranty replacements is covered by TOPNLMS for orders shipped to mainland China, Hong Kong, and Taiwan. For international destinations, return freight terms are agreed at the time of the claim.

Our after-sales team is reachable by email at [email protected] and by phone at +86 18359293191 during business hours (GMT+8, Monday–Saturday). Technical questions regarding installation, wiring, or IndraWorks compatibility can be directed to the same contact. We maintain stock of the VDP40.3DIN-D1-NN-CG and related IndraControl V components to support rapid dispatch for urgent breakdown situations.

For volume procurement, OEM replacement programs, or standing purchase orders covering multiple IndraControl V panel types, please contact our sales team directly to discuss pricing, lead times, and consignment stock arrangements.

Quick Inquiry

Click Quote This Model and the Part Number field will auto-fill with VDP40.3DIN-D1-NN-CG.