Request availability, condition, lead time and export shipping details for 1734-IT2I.
Send this exact part number, quantity and destination country. TOPNLMS will confirm availability, condition and export lead time before quotation.
The Allen-Bradley 1734-IT2I is a dual-channel isolated thermocouple input module engineered for the POINT I/O platform — one of Rockwell Automation’s most widely deployed distributed I/O architectures in mission-critical industrial environments. Designed to deliver precise, stable temperature measurement under extreme operating conditions, the 1734-IT2I is the preferred choice for engineers and procurement teams managing control systems in oil & gas, mining, power generation, water treatment, metallurgy, and heavy manufacturing facilities.
Unlike standard analog input modules, the 1734-IT2I incorporates channel-to-channel isolation that protects measurement integrity in environments plagued by ground loops, electromagnetic interference (EMI), and high-voltage transients. Whether installed in a control cabinet adjacent to variable frequency drives, servo amplifiers, or high-current motor starters, the module maintains signal accuracy without cross-channel contamination — a critical requirement in continuous production lines where a single erroneous temperature reading can trigger unplanned shutdowns or compromise process safety.
The module supports multiple thermocouple types (J, K, E, T, R, S, B, N, C), giving system integrators the flexibility to standardize on a single I/O module across diverse thermal measurement points throughout a plant. Its high-resolution 16-bit analog-to-digital conversion ensures that even small temperature deviations are captured accurately, supporting tight process control loops in applications such as furnace temperature regulation, heat exchanger monitoring, and reactor thermal management.
In harsh-environment deployments, the 1734-IT2I operates reliably within the broader POINT I/O ecosystem. It mounts directly onto the 1734-TOP or 1734-TOP3L terminal base, and communicates through the POINT I/O backplane to adapter modules such as the 1734-AENT (EtherNet/IP adapter) or 1734-PDN (DeviceNet adapter), enabling seamless integration into ControlLogix, CompactLogix, or MicroLogix-based control architectures. The module’s compact DIN-rail form factor allows dense I/O packing within space-constrained control enclosures, while its removable terminal base simplifies field replacement without rewiring — a significant advantage in facilities where minimizing maintenance downtime is paramount.
For installations in dusty, high-humidity, or chemically aggressive atmospheres, the 1734-IT2I’s sealed construction and conformal-coated PCB options provide an additional layer of protection. When paired with 1734-VHSC24 high-speed counter modules, 1734-OB8 digital output modules, or 1734-IB8 digital input modules within the same POINT I/O rack, the system delivers a fully coordinated, rugged I/O solution capable of handling both discrete and analog signals from a single distributed node — reducing wiring complexity and improving system diagnostics.
In power generation and substation environments, where electromagnetic interference from high-voltage switching equipment is a constant challenge, the 1734-IT2I’s channel isolation and shielded signal paths ensure that temperature data from turbine exhaust sensors, transformer winding monitors, or cooling system probes remains accurate and uninterrupted. Similarly, in offshore oil & gas platforms and onshore refineries, where the module may be installed in Zone 2 hazardous areas using appropriate enclosures, its robust design supports long-term, maintenance-free operation between scheduled turnarounds.
Procurement teams sourcing the 1734-IT2I as a spare part or replacement module will find that TOPNLMS maintains verified stock, with each unit undergoing pre-shipment functional testing to confirm channel accuracy, isolation integrity, and backplane communication. All modules are shipped with full documentation and are covered by a 12-month warranty against manufacturing defects — providing the supply chain assurance that industrial operations demand.
| Parameter | Specification |
|---|---|
| Part Number / SKU | 1734-IT2I |
| Brand / Manufacturer | Allen-Bradley (Rockwell Automation) |
| Series | POINT I/O (1734 Series) |
| Module Type | Dual-Channel Isolated Thermocouple Input |
| Number of Channels | 2 (channel-to-channel isolated) |
| Supported Thermocouple Types | J, K, E, T, R, S, B, N, C |
| Resolution | 16-bit ADC |
| Operating Temperature | 0°C to 55°C (32°F to 131°F) |
| Storage Temperature | -40°C to 85°C (-40°F to 185°F) |
| Relative Humidity | 5% to 95% non-condensing |
| Vibration Resistance | IEC 60068-2-6 compliant |
| Shock Resistance | IEC 60068-2-27 compliant |
| EMI/RFI Protection | Channel-to-channel isolation; shielded signal paths |
| Backplane Interface | POINT I/O (1734 Series) |
| Compatible Terminal Bases | 1734-TOP, 1734-TOP3L |
| Compatible Adapters | 1734-AENT (EtherNet/IP), 1734-PDN (DeviceNet), 1734-ACNR (ControlNet) |
| Compatible Controllers | ControlLogix, CompactLogix, MicroLogix |
| Mounting | DIN Rail via POINT I/O terminal base |
| Country of Origin | United States |
| Product Category | Industrial Automation > PLC I/O Modules > Analog Input Modules |
| Warranty | 12 Months (TOPNLMS) |
| Pre-Shipment Testing | Yes — channel accuracy, isolation, and backplane communication verified |
The 1734-IT2I is rarely deployed in isolation. In a typical POINT I/O control cabinet, it operates alongside the 1734-AENT EtherNet/IP adapter, which aggregates data from all I/O modules on the node and transmits it over a standard Ethernet network to the ControlLogix or CompactLogix controller. For applications requiring DeviceNet connectivity, the 1734-PDN adapter serves the same aggregation role over the CAN-based DeviceNet protocol.
On the digital side, 1734-IB8 8-channel 24VDC digital input modules and 1734-OB8 8-channel digital output modules are commonly installed in the same rack to handle discrete signals from limit switches, proximity sensors, solenoid valves, and motor contactors. For high-speed pulse counting or encoder feedback, the 1734-VHSC24 high-speed counter module complements the 1734-IT2I’s analog temperature data with precise motion and flow measurements.
Power distribution within the POINT I/O node is managed by the 1734-EP24DC power supply module, which provides isolated 24VDC bus power to field-side circuits, protecting the backplane from power-side disturbances. In control cabinets where multiple I/O nodes are installed, a 1734-ACNR ControlNet adapter may be used to provide redundant network connectivity, ensuring that a single cable fault does not interrupt process monitoring.
For safety-rated applications, the 1734-IT2I can be integrated into architectures that include GuardLogix safety controllers and 1791DS-IB8XOBV4 safety I/O modules, where temperature monitoring is part of a broader safety instrumented function (SIF). In such configurations, the thermocouple data from the 1734-IT2I feeds into the safety logic to trigger protective actions — such as emergency shutdowns or cooling system activation — when process temperatures exceed defined safe operating limits.
In oil and gas upstream and midstream facilities, the 1734-IT2I is deployed to monitor temperatures across compressor stations, heat exchangers, and pipeline heating systems. Its channel isolation is particularly valuable in these environments, where long thermocouple cable runs from remote measurement points introduce significant common-mode noise that would corrupt readings on non-isolated modules.
In coal-fired and gas-fired power generation plants, the module monitors boiler tube temperatures, turbine exhaust gas temperatures, and cooling water temperatures — all critical parameters for both efficiency optimization and equipment protection. The module’s compatibility with the ControlLogix platform allows it to integrate directly into the plant’s distributed control system (DCS) architecture, providing operators with real-time thermal data on their SCADA displays.
In metallurgical and steel production facilities, where furnace temperatures routinely exceed 1,000°C and the surrounding environment is characterized by intense radiant heat, vibration from heavy machinery, and airborne metallic dust, the 1734-IT2I’s rugged construction and support for high-temperature thermocouple types (R, S, B) make it the module of choice for furnace temperature control loops. Its removable terminal base design allows maintenance technicians to replace a faulty module in minutes without interrupting the thermocouple wiring — a critical capability in continuous casting operations where any unplanned stoppage carries significant production cost.
In water and wastewater treatment plants, the module monitors temperatures in biological reactors, sludge digesters, and chemical dosing systems, where stable and accurate temperature measurement is essential for process efficiency and regulatory compliance. Its low-power consumption and compact form factor make it well-suited for installation in remote pump station control panels with limited space and power budgets.
Q1: What warranty coverage does TOPNLMS provide for the 1734-IT2I?
All 1734-IT2I modules supplied by TOPNLMS are covered by a 12-month warranty against manufacturing defects and functional failures. If a module fails within the warranty period under normal operating conditions, TOPNLMS will arrange replacement or repair at no additional cost. Warranty claims are processed promptly to minimize impact on your production operations.
Q2: How is each module tested before shipment?
Every 1734-IT2I unit undergoes a pre-shipment functional test that verifies channel-to-channel isolation integrity, thermocouple input accuracy across supported types, and backplane communication with a POINT I/O adapter. Only modules that pass all test criteria are released for shipment. A test record is available upon request for quality-critical procurement processes.
Q3: Is the 1734-IT2I compatible with my existing ControlLogix or CompactLogix system?
Yes. The 1734-IT2I is fully compatible with all POINT I/O adapter modules and integrates seamlessly into ControlLogix, CompactLogix, and MicroLogix control architectures via EtherNet/IP, DeviceNet, or ControlNet adapters. The module’s Add-On Profile (AOP) is supported in Studio 5000 Logix Designer, enabling straightforward configuration and commissioning without custom programming.
Q4: Can TOPNLMS support long-term or repeat supply of the 1734-IT2I?
Yes. TOPNLMS maintains ongoing stock of the 1734-IT2I and other POINT I/O modules to support both immediate replacement needs and planned maintenance programs. For facilities managing large installed bases of Allen-Bradley POINT I/O systems, TOPNLMS can provide scheduled supply agreements to ensure spare parts availability without the lead-time uncertainty associated with standard distribution channels. Contact our team at [email protected] or +86 18359293191 to discuss your requirements.
Click Quote This Model and the Part Number field will auto-fill with 1734-IT2I.