YASKAWA YPLT31006-1A Replacement for AC Drive Series
YPLT31006-1AYASKAWA YPLT31006-1A AC drive control PCB replacement & upgrade. Compatible with YASKAWA G7/F7/E7 series. 12-month warranty, fast shipping. Order now.
Request availability, condition, lead time and export shipping details for CIMR-G7A4011.
Send this exact part number, quantity and destination country. TOPNLMS will confirm availability, condition and export lead time before quotation.
In modern industrial facilities, the variable frequency drive (VFD) is one of the most operationally critical components in any motor control circuit. The YASKAWA CIMR-G7A4011 — a 15kW, 400V AC drive from YASKAWA’s proven G7 Series — is a factory-original spare part trusted by maintenance engineers across manufacturing, water treatment, HVAC, material handling, and process automation industries worldwide. Whether you are managing a scheduled overhaul, responding to an unplanned shutdown, or building a strategic spare parts inventory, the CIMR-G7A4011 delivers the reliability and compatibility your operation demands.
| Model / SKU | CIMR-G7A4011 |
| Brand | YASKAWA Electric Corporation |
| Series | G7 (Varispeed G7) |
| Rated Output Power | 15 kW (20 HP) |
| Input Voltage | 380–480V AC, 3-Phase |
| Output Voltage | 0–480V AC, 3-Phase |
| Output Current | 31 A (Heavy Duty) |
| Control Method | Open-loop Vector / V/f / Flux Vector |
| Frequency Range | 0.01–400 Hz |
| Protection Rating | IP00 (open chassis); IP20 optional |
| Cooling Method | Forced air cooling |
| Ambient Temperature | -10°C to +40°C (operating) |
| Communication | MEMOBUS/Modbus RTU (RS-422/485); optional PROFIBUS, DeviceNet |
| Compatibility | Direct replacement for CIMR-G7A4011 in G7 Series control panels |
| Origin | Japan |
| Warranty | 12 Months from date of shipment |
A VFD failure rarely occurs in isolation. When a CIMR-G7A4011 is flagged for replacement during a scheduled inspection or emergency shutdown, experienced maintenance teams treat the event as a trigger for a broader system health check. The drive sits at the center of a motor control circuit that depends on the integrity of every upstream and downstream component.
Begin with the input power section: inspect the dedicated fuse module or MCCB protecting the drive’s input terminals — a weakened fuse or breaker that has experienced nuisance trips may have contributed to drive stress. Check the AC reactor or line filter installed upstream; these components absorb voltage spikes and harmonic distortion that degrade drive IGBTs over time. If the reactor shows signs of overheating or insulation breakdown, replace it alongside the CIMR-G7A4011.
Move to the control wiring and terminal block section. Loose or corroded terminals on the control board connector strip are a leading cause of intermittent faults in G7 Series drives. Inspect the multi-function I/O terminal board and verify that analog input signals (frequency reference, torque reference) are within specification. If the drive communicates via MEMOBUS/Modbus RTU, inspect the RS-485 communication cable and the termination resistor — a degraded cable can cause communication timeouts that mimic drive faults.
For facilities running YASKAWA G7 drives in multi-drive panels, also inspect the 24VDC control power supply module feeding the PLC or relay logic. A sagging control voltage causes erratic run/stop commands and can mask the true source of a drive trip. Similarly, check the safety relay module or emergency stop circuit — if the STO (Safe Torque Off) input is wired, verify the relay contacts are clean and within rated switching cycles.
On the motor side, use a megohmmeter to test the motor winding insulation resistance before reconnecting the new drive. A motor with degraded insulation will immediately stress the replacement IGBT output stage. Also inspect the motor encoder or PG feedback card if the system runs in closed-loop vector mode — a faulty encoder signal is a common cause of oscillation and overcurrent faults on G7 drives.
Finally, review the cooling system inside the control cabinet: clean or replace the cabinet door filter mats, verify that the internal cooling fan (if fitted) is operational, and confirm that ambient temperature at the drive’s installation location does not exceed 40°C. Thermal stress is the primary accelerator of capacitor aging inside VFDs, and a clean, cool cabinet directly extends the service life of the replacement CIMR-G7A4011.
The YASKAWA G7 Series has been deployed globally since the early 2000s, and many facilities continue to operate G7-based motor control systems well into their second decade of service. Sourcing a genuine CIMR-G7A4011 as a direct replacement eliminates the engineering risk associated with cross-brand substitution: no parameter remapping, no wiring adapter, no revalidation of the control loop. The drive mounts in the original footprint, accepts the existing control wiring, and retains full compatibility with YASKAWA’s DriveWizard configuration software.
For facilities managing aging G7 fleets, maintaining at least one CIMR-G7A4011 as a critical spare in the storeroom is a proven strategy for reducing mean time to repair (MTTR). A single unplanned production stoppage on a 15kW drive circuit — powering a conveyor, pump, compressor, or fan — can cost multiples of the spare part’s value within hours. Proactive inventory of this model, combined with documented parameter backup files, enables a technician to restore full operation within a single shift.
Each unit supplied by TOPNLMS is sourced from authorized channels, inspected prior to shipment, and covered by a 12-month warranty. Units are shipped with original packaging and documentation where available, and export compliance documentation can be provided upon request for international shipments.
Q1: Is this a genuine YASKAWA CIMR-G7A4011 or an aftermarket equivalent?
This is a factory-original YASKAWA CIMR-G7A4011 unit. We do not supply aftermarket, remanufactured, or clone substitutes. Each unit is verified before shipment.
Q2: What is covered under the 12-month warranty?
The warranty covers manufacturing defects and functional failures under normal operating conditions for 12 months from the date of shipment. It does not cover damage caused by incorrect installation, overvoltage events, or operation outside rated parameters.
Q3: Can this drive replace an older CIMR-G7A4011 without reprogramming?
Yes. As a direct model-for-model replacement, the CIMR-G7A4011 retains the same parameter structure as the original. We recommend uploading a saved parameter file from the outgoing drive using DriveWizard before installation to minimize commissioning time.
Q4: How quickly can this unit be shipped, and what testing is performed before dispatch?
In-stock units are typically dispatched within 1–3 business days. Each drive undergoes a pre-shipment functional check. Express international shipping options are available. Contact us for lead time confirmation on your specific order quantity.