Language English USD Currency
Call WhatsApp RFQ
Schneider Electric Industrial Automation Part

Schneider NSX160N Replacement Upgrade for Compact NSX Series

Request availability, condition, lead time and export shipping details for NSX160N.

Schneider Electric

NSX160N

Send this exact part number, quantity and destination country. TOPNLMS will confirm availability, condition and export lead time before quotation.

Part NumberNSX160N
ConditionAvailability Check
Lead TimeRFQ Confirmation
SeriesCompact NSX
ShippingExport packing available
Model checked before quotation Condition and packing confirmed Fast RFQ response by sales engineer

Product Overview

Schneider NSX160N Replacement Upgrade for Compact NSX Series: Smooth Transition & Legacy System Compatibility

Upgrading or replacing a Schneider Electric Compact NSX molded case circuit breaker in an active industrial control panel demands precision — not just in the breaker itself, but in every aspect of the migration: wiring compatibility, DIN rail or fixed-mount footprint, upstream/downstream coordination, and communication with the broader power distribution architecture. The NSX160N (160A, 50kA breaking capacity, 3-pole, fixed mount) is a direct-fit replacement and modernization solution for aging or discontinued Compact NSX installations across manufacturing plants, process automation facilities, water treatment systems, and building management infrastructure.

Whether your existing panel houses an older NS160N from the legacy Compact NS series, a worn NSX160B (25kA variant) that no longer meets updated fault-current requirements, or a discontinued C160N from earlier Merlin Gerin lineage, the NSX160N slots into the same fixed three-pole mounting position with identical pole pitch and terminal geometry. Downstream wiring to motor starters, variable frequency drives, or sub-distribution boards requires no re-termination in most retrofit scenarios, significantly reducing panel downtime during changeover.

Compatibility Comparison Table

Parameter Legacy / Outgoing Model NSX160N (This Unit) Retrofit Notes
Rated Current NS160N / C160N / NSX160B 160A (In) Direct current rating match
Breaking Capacity (Icu) 25kA (NSX160B) / 36kA (NS160N) 50kA @ 415V AC Upgraded fault protection — no derating required
Poles 3P 3P Identical pole configuration
Mounting Type Fixed Fixed Same fixed chassis — no adapter plate needed
Terminal Type Front cable / rear cable Front cable (standard) / rear cable optional Confirm terminal orientation before ordering
Pole Pitch / Footprint Compact NSX standard Compact NSX standard Panel cutout and busbar spacing unchanged
Auxiliary / Signaling OF, SD, SDE contacts Compatible OF, SD, SDE accessory slots Existing auxiliary wiring reusable
Communication Micrologic trip unit (optional) Micrologic trip unit compatible (optional add-on) Modbus / IEC 61850 via Micrologic module
Standards IEC 60947-2 IEC 60947-2 Full compliance — no re-certification required
Warranty 12-Month Warranty Covered from date of shipment

Seamless Upgrade Solutions

A successful NSX160N migration rarely involves the circuit breaker alone. In most Compact NSX panel retrofits, the changeover is coordinated with adjacent components that share the same control cabinet, power bus, or communication backbone. When replacing an upstream feeder breaker, engineers typically verify coordination with downstream NSX100N or NSX250N branch breakers to maintain selective tripping across the distribution hierarchy — ensuring that a fault on one outgoing circuit does not trip the entire feeder.

For panels where the NSX160N protects a motor feeder, the downstream TeSys D or TeSys K contactor and thermal overload relay assembly often remains unchanged, as the breaker’s terminal geometry and cable entry points are preserved. In variable-speed drive applications, the NSX160N is commonly installed upstream of Altivar 312 or Altivar 630 drives, where its 50kA breaking capacity provides the fault current withstand demanded by modern drive input specifications.

Where the legacy installation included a Micrologic 2.0 or Micrologic 5.0 electronic trip unit for metering and protection coordination, the NSX160N chassis accepts the same Micrologic trip unit family, preserving existing Modbus RTU or IEC 61850 communication wiring back to the SCADA or energy management system. This is particularly valuable in facilities running EcoStruxure Power architectures, where breaker-level metering data feeds directly into the plant’s power monitoring dashboard without requiring gateway reconfiguration.

In multi-breaker distribution boards, the NSX160N is frequently installed alongside iC60N or iC60H miniature circuit breakers on the outgoing ways, with the NSX160N serving as the incomer. The shared Compact NSX busbar system and comb busbar accessories remain compatible, eliminating the need to replace the busbar assembly during the retrofit. For installations requiring earth leakage protection, the Vigi NSX earth leakage add-on module mounts directly to the NSX160N without modification to the panel structure.

Control wiring connected to auxiliary contacts — including OF (open/closed position), SD (fault signal), and SDE (earth fault signal) contacts — can be reused directly from the legacy breaker, as the NSX accessory slot positions and wiring conventions are consistent across the Compact NSX generation. This preserves PLC input wiring to Modicon M340 or Modicon M580 controllers that monitor breaker status as part of the plant’s electrical supervision logic.

Retrofit Guidance FAQ

Q: Can I reuse existing cable terminations when replacing an NS160N with the NSX160N?
A: In most cases, yes. The NSX160N uses the same terminal pitch and cable entry geometry as the Compact NSX platform. If the legacy unit is an older Compact NS (NS160N), a terminal adapter may be required — confirm the panel’s cable lug size and terminal torque specification before installation.

Q: Will my existing Micrologic trip unit transfer to the NSX160N?
A: Micrologic trip units designed for the Compact NSX chassis (Micrologic 2.0, 5.0, 6.0, 7.0) are compatible with the NSX160N. Micrologic units from the legacy Compact NS series are not directly interchangeable — verify the trip unit generation before transfer.

Q: Does the NSX160N support Modbus communication for SCADA integration?
A: Yes, when fitted with a compatible Micrologic electronic trip unit and the ULP (Universal Logic Plug) communication interface, the NSX160N supports Modbus RTU communication. This allows integration with existing SCADA, DCS, or EcoStruxure Power Monitoring Expert systems without rewiring the communication bus.

Q: What is the physical installation space requirement?
A: The NSX160N fixed 3P unit occupies the standard Compact NSX footprint. Panel depth, width allocation per pole, and DIN rail or direct-mount screw positions are identical to existing Compact NSX installations. No panel modification or new cutout is required for a like-for-like replacement.

Q: How do I verify selective coordination with downstream breakers?
A: Use Schneider Electric’s EcoStruxure Power Design or the Selectivity Guide for Compact NSX to confirm time-current curve coordination between the NSX160N and downstream NSX100N, NSX250N, or iC60 breakers. The 50kA Icu of the NSX160N provides coordination margin in most LV distribution scenarios up to 415V.

Q: Can the NSX160N replace a Compact NS160N in a withdrawable configuration?
A: The NSX160N in fixed configuration cannot directly replace a withdrawable (plug-in or draw-out) Compact NS unit without a chassis adapter. Contact our technical team to confirm the correct chassis variant for withdrawable panel applications.

Warranty Assurance

Every NSX160N unit shipped by TOPNLMS is covered by a 12-month warranty from the date of shipment. Prior to dispatch, each unit undergoes functional verification including insulation resistance check, trip mechanism actuation test, and visual inspection of terminal integrity and rating label accuracy. Units are packed in anti-static, shock-resistant packaging suitable for international air freight and sea freight.

In the event of a confirmed defect within the warranty period, TOPNLMS provides replacement dispatch within 3 business days of fault confirmation, with return freight covered for verified warranty claims. Our after-sales response team is reachable via email at [email protected] or by phone at +86 18359293191, with response times typically within 24 hours on business days.

Stock availability is maintained for immediate dispatch from our Xiamen warehouse. Lead times for in-stock units are 1–3 business days for domestic China delivery and 5–10 business days for international destinations via DHL, FedEx, or UPS Express. Bulk procurement inquiries, project-quantity pricing, and consignment stocking arrangements are available upon request.

TOPNLMS specializes in sourcing, testing, and supplying industrial automation and power distribution components for MRO (Maintenance, Repair & Operations) and capital project procurement teams. Our catalog covers Schneider Electric, Siemens, ABB, Rockwell Automation, Mitsubishi Electric, and Omron product lines, with a focus on replacement, upgrade, and obsolescence management solutions for active industrial facilities.

Quick Inquiry

Click Quote This Model and the Part Number field will auto-fill with NSX160N.