Schneider 140CPS22400 Replacement for Modicon Quantum
140CPS22400Drop-in 140CPS22400 replacement for Modicon Quantum. DC 24V 8A redundant power supply. Compatibility verified, 12-month warranty, fast global shipping.
Request availability, condition, lead time and export shipping details for TSXPSY2600.
Send this exact part number, quantity and destination country. TOPNLMS will confirm availability, condition and export lead time before quotation.
The Schneider Electric TSXPSY2600 is an original rack-mounted power supply module engineered specifically for the Modicon TSX Premium PLC platform — one of the most widely deployed programmable logic controller families in process automation, discrete manufacturing, and infrastructure control worldwide. As industrial facilities continue to operate aging TSX Premium systems well beyond their original design life, maintaining a verified, original-specification power supply module in your spare parts inventory is not a luxury — it is a fundamental pillar of operational continuity.
Power supply failures are among the leading causes of unplanned PLC downtime. Unlike peripheral I/O faults that may degrade performance gradually, a failed rack power supply causes an immediate, complete system shutdown. In high-throughput production lines, water treatment facilities, or energy distribution substations, even a 30-minute outage can translate into significant financial loss and safety risk. The TSXPSY2600 eliminates this vulnerability by providing a direct, plug-compatible replacement that restores full rack power capacity without requiring firmware reconfiguration, hardware adaptation, or system re-commissioning.
| Parameter | Specification |
|---|---|
| Part Number / SKU | TSXPSY2600 |
| Brand | Schneider Electric (Original) |
| Series Compatibility | Modicon TSX Premium (TSX P57 / TSX P47 / TSX P37 series racks) |
| Module Type | Rack Power Supply Module |
| Input Voltage | 100–240 V AC, 47–63 Hz (wide-range universal input) |
| Output Power | 26 W total rack bus power |
| Output Voltages | +5 V DC (logic bus), +24 V DC (sensor/actuator bus) |
| Protection Class | Short-circuit, overload, and overvoltage protection |
| Mounting | Direct rack slot installation — no tools required |
| Operating Temperature | 0°C to +60°C |
| Storage Temperature | -25°C to +70°C |
| Humidity | 5% to 95% non-condensing |
| Country of Origin | France |
| Certifications | CE, UL, cUL (original factory certifications) |
| Maintenance Recommendation | Inspect every 12–24 months; replace at first sign of output voltage drift or thermal anomaly |
| Warranty | 12 Months — covers manufacturing defects, tested before shipment |
A disciplined preventive maintenance program for TSX Premium-based control systems extends well beyond replacing a single module. When scheduling a planned shutdown for TSXPSY2600 inspection or replacement, experienced maintenance engineers treat the event as an opportunity to audit the entire control cabinet. The power supply module is the heart of the rack, but its health is directly interdependent with the components it powers and the environment it operates in.
Begin with the TSX Premium rack backplane itself — inspect the bus connectors for oxidation, carbon tracking, or mechanical deformation that could cause intermittent contact resistance and false power faults. Next, audit all installed I/O modules such as the TSXDEY16D2 digital input module and TSXDSY16T2 digital output module: verify that their status LEDs cycle correctly on power-up and that no channels are reporting persistent faults that could indicate a downstream wiring short loading the 24 V bus.
The TSXPSY2600‘s 24 V sensor bus powers field devices throughout the cabinet. During the maintenance window, inspect all terminal blocks and wiring harnesses connected to this bus — loose terminations and corroded ferrules are a common source of intermittent voltage drops that are often misdiagnosed as power supply degradation. If your facility uses signal isolators or relay output modules such as the TSXRKY4EX extension rack, verify that their power draw remains within the TSXPSY2600’s rated output budget.
Communication integrity is equally critical. Inspect the TSXSCP114 or equivalent Uni-Telway / Modbus communication module seated in the rack — communication modules are sensitive to power supply ripple, and a degrading TSXPSY2600 often manifests first as intermittent communication timeouts before causing a full rack shutdown. Similarly, check the TSXETY110 Ethernet module if your system uses TCP/IP-based SCADA connectivity.
For facilities running Magelis HMI panels connected to the TSX Premium CPU, confirm that the HMI power supply is on a separate, isolated circuit — HMI power faults should never cascade into PLC rack instability. Finally, review the condition of the 24 V DC external power supply feeding the field I/O loop: brands like Schneider Electric’s Phaseo ABL series are commonly paired with TSX Premium racks and should be inspected for output voltage accuracy and capacitor aging simultaneously with the TSXPSY2600 replacement.
Documenting all findings in a maintenance log — including measured output voltages, ambient cabinet temperature, and module serial numbers — creates a traceable service record that supports future predictive maintenance scheduling and spare parts budgeting.
The TSXPSY2600 is a direct, form-fit-function replacement for the original power supply position in all TSX Premium rack configurations. Unlike third-party alternatives that may require voltage trimming, jumper reconfiguration, or firmware compatibility verification, an original Schneider Electric TSXPSY2600 installs in minutes and is immediately recognized by the TSX Premium CPU without any parameter changes in Unity Pro or PL7 Pro programming software.
For facilities managing the end-of-life transition of TSX Premium systems, stocking one or two TSXPSY2600 units as cold-standby spares is a proven strategy to extend system operational life by 5–10 years without the capital expenditure of a full PLC platform migration. This approach is particularly valuable in applications where the control program is deeply integrated with proprietary function blocks, custom I/O mapping, or legacy SCADA drivers that would require significant re-engineering to migrate to a Modicon M340 or M580 platform.
When a TSXPSY2600 failure occurs in the field, the replacement procedure is straightforward: de-energize the rack, remove the failed module by releasing the front-panel locking lever, insert the replacement unit, restore power, and verify that all rack module status indicators return to normal within the standard boot sequence. No tools, no calibration, no re-programming. This plug-and-play replacement capability is the core value proposition of maintaining original-specification spare parts versus attempting field repairs on failed modules.
All TSXPSY2600 units supplied by TOPNLMS are individually tested for output voltage accuracy, ripple, and protection circuit functionality prior to shipment. Each unit ships with a test report and is covered by a 12-month warranty against manufacturing defects.
Q1: Is this TSXPSY2600 an original Schneider Electric module or a compatible replacement?
This is an original Schneider Electric TSXPSY2600 module — not a clone, compatible, or remanufactured unit. All units are sourced from authorized industrial distribution channels and are verified for authenticity before listing. Original modules ensure full compatibility with TSX Premium rack bus architecture and carry the factory CE/UL certifications required for regulated industries.
Q2: How many TSXPSY2600 units should I stock as spare parts?
For facilities operating a single TSX Premium rack, a minimum of one cold-standby unit is recommended. For multi-rack installations or critical 24/7 processes (utilities, food & beverage, pharmaceuticals), two units per site is the industry-standard recommendation. Given the TSXPSY2600’s end-of-production status, procurement lead times from the OEM can be unpredictable — stocking spares now eliminates emergency sourcing risk.
Q3: What testing is performed before shipment, and what does the 12-month warranty cover?
Each TSXPSY2600 undergoes pre-shipment functional testing including: output voltage verification on both the 5 V logic bus and 24 V sensor bus, overload protection circuit activation test, and visual inspection for physical damage. The 12-month warranty covers all manufacturing defects and functional failures under normal operating conditions. It does not cover damage caused by incorrect installation, overvoltage events, or physical mishandling after delivery.
Q4: Can the TSXPSY2600 be used in TSX Micro or Modicon M340 racks?
No. The TSXPSY2600 is designed exclusively for the TSX Premium rack platform. It is not compatible with TSX Micro (which uses a different integrated power supply architecture) or Modicon M340/M580 racks (which use BMX/BME series power supply modules). Always verify your rack reference number before ordering — TSX Premium racks are identified by the TSXRKY prefix (e.g., TSXRKY4, TSXRKY6, TSXRKY8, TSXRKY12).
Click Quote This Model and the Part Number field will auto-fill with TSXPSY2600.