Language English USD Currency
Call WhatsApp RFQ
Schneider Electric Industrial Automation Part

Schneider Electric MT06N1 Original Industrial Spare Masterpact MT Compatible

Request availability, condition, lead time and export shipping details for MT06N1.

Schneider Electric

MT06N1

Send this exact part number, quantity and destination country. TOPNLMS will confirm availability, condition and export lead time before quotation.

Part NumberMT06N1
ConditionAvailability Check
Lead TimeRFQ Confirmation
SeriesOther series
ShippingExport packing available
Model checked before quotation Condition and packing confirmed Fast RFQ response by sales engineer

Product Overview

Schneider Electric MT06N1 Original Industrial Spare Masterpact MT Compatible: System Stability & Industrial Spare Parts Maintenance Value

The Schneider Electric MT06N1 is a genuine Masterpact MT series 630A 3-pole air circuit breaker (ACB) rated at 690V AC, fully compliant with IEC 60947-2. Designed for demanding industrial power distribution environments, the MT06N1 serves as a critical protection and switching device in main distribution boards, motor control centers (MCCs), and industrial control cabinets across manufacturing plants, process industries, utilities, and infrastructure facilities. Sourced directly from authorized supply channels, every MT06N1 unit stocked at TOPNLMS undergoes pre-shipment functional verification to ensure it meets original factory specifications before dispatch.

In industrial maintenance operations, the air circuit breaker is the first line of defense for downstream electrical systems. When an MT06N1 fails or reaches end-of-life, the consequences extend far beyond a single breaker: unplanned downtime, cascading protection failures, and costly emergency procurement under production pressure. Maintaining a certified spare MT06N1 in your on-site inventory is one of the most cost-effective risk mitigation strategies available to maintenance engineers managing Masterpact MT-equipped switchgear.

Critical Technical Specs Table

Parameter Specification
Part Number / SKU MT06N1
Brand Schneider Electric
Series Masterpact MT
Product Type Air Circuit Breaker (ACB)
Rated Current (In) 630A
Poles 3P (Three-Pole)
Rated Voltage (Ue) 690V AC
Compliance Standard IEC 60947-2
Breaking Capacity N-frame (per Masterpact MT N-class rating)
Trip Unit Compatibility Micrologic trip units (A, E, P series)
Mounting Fixed or withdrawable chassis (frame-dependent)
Country of Origin France
Application Environment Industrial switchgear, MCC, main distribution boards
Maintenance Recommendation Inspect contacts, trip mechanism, and arc chutes every 12–24 months or per OEM schedule
Warranty 12 Months (TOPNLMS)
Weight Approx. 2,100g

Preventive Maintenance Strategy

A scheduled maintenance program built around the MT06N1 should extend beyond the breaker itself. In practice, the MT06N1 operates within a broader electrical protection and control architecture, and the reliability of the entire system depends on the condition of every interconnected component. During planned shutdowns or annual inspections, maintenance teams should treat the MT06N1 replacement or overhaul as an opportunity to audit the full control cabinet.

Begin with the upstream and downstream wiring: inspect the copper busbars and insulated power cables connecting the MT06N1 to the transformer secondary and to downstream distribution panels. Loose terminations and aged cable insulation are among the most common root causes of nuisance tripping in Masterpact MT installations. At the same time, verify the condition of the Micrologic trip unit installed in the breaker frame — the Micrologic 2.0A, 5.0A, or 6.0E variants each have distinct protection curves, and a degraded trip unit can compromise the entire protection coordination scheme.

Within the same switchgear lineup, it is standard practice to simultaneously inspect the Masterpact MT auxiliary contacts and motor mechanisms (MN, MX, XF coil accessories), as these are wear items that often fail before the main breaker frame. If the installation includes a Masterpact MT08N1 or MT10N1 in the same distribution board, those units should be included in the same inspection cycle to maintain consistent protection grading across the feeder hierarchy.

For the control circuit side, check the 24VDC or 110VAC control power supply modules feeding the trip coils and communication interfaces. A failing control power supply is a silent risk: the breaker may appear operational during normal load conditions but fail to respond to a trip command during a fault event. Alongside this, inspect the Modbus or IEC 61850 communication modules (if fitted) to ensure remote monitoring and SCADA integration remain functional — communication failures can mask developing faults for weeks before a catastrophic event.

In the same cabinet, terminal blocks and DIN rail-mounted fuse modules protecting the control wiring should be checked for discoloration, loose connections, and blown fuses. Signal isolators and relay modules in the protection relay panel adjacent to the MT06N1 feeder should also be tested for correct operation. If the installation uses a Schneider Electric Easergy or Sepam protection relay coordinated with the MT06N1, verify that the relay settings and CT secondary wiring remain within calibration. Finally, inspect the HMI or local control panel display for any latched fault codes or communication alarms that may indicate a developing issue in the power distribution system.

Stocking a spare MT06N1 alongside a Micrologic trip unit, a set of MN/MX coil accessories, and a compatible control power supply module creates a complete emergency response kit that can restore a tripped or failed feeder within hours rather than days — a critical advantage in continuous-process industries where every hour of downtime carries significant financial impact.

Strategic Replacement Solutions

The MT06N1 is the direct OEM replacement for aging Masterpact M or earlier Compact NS-series installations that have been upgraded to the Masterpact MT platform. Its standardized frame dimensions and IEC 60947-2 compliance make it a drop-in replacement in most existing switchgear lineups without requiring busbar modifications or panel re-engineering, significantly reducing the labor cost and downtime associated with a breaker replacement event.

For facilities managing legacy Schneider Electric M-series or Merlin Gerin Masterpact installations, the MT06N1 provides a clear migration path: the Masterpact MT frame accepts the full range of current Micrologic trip units, enabling facilities to upgrade their protection intelligence (adding earth fault, power metering, or harmonic monitoring capabilities) while reusing existing switchgear infrastructure. This approach extends the useful life of the control cabinet by 10–15 years, deferring the capital expenditure of a full switchgear replacement.

When planning a replacement, always verify the existing trip unit model and protection settings before removing the old breaker. Document the Ir, Im, and Isd settings from the Micrologic unit, and confirm that the replacement MT06N1 frame is compatible with the installed trip unit variant. TOPNLMS provides pre-shipment testing documentation for each MT06N1 unit, confirming that the mechanical trip mechanism, contact resistance, and insulation resistance meet factory acceptance criteria before the unit leaves our warehouse.

Support FAQ

Q1: Is the MT06N1 compatible with existing Masterpact MT withdrawable chassis?
Yes. The MT06N1 is designed for the Masterpact MT frame and is compatible with both fixed and withdrawable chassis configurations used in the Masterpact MT lineup. Always confirm the chassis reference (horizontal or vertical racking) with your switchgear documentation before ordering.

Q2: What is the warranty coverage for the MT06N1 supplied by TOPNLMS?
All MT06N1 units supplied by TOPNLMS carry a 12-month warranty covering manufacturing defects and functional failures under normal operating conditions. Each unit undergoes pre-shipment inspection including contact resistance measurement and mechanical trip verification. Warranty claims are supported with full documentation and replacement dispatch within agreed lead times.

Q3: How do I verify compatibility before installing the MT06N1 as a replacement?
Confirm the existing breaker’s rated current (630A), pole configuration (3P), voltage rating (690V AC), and trip unit model from the original switchgear documentation or nameplate. Cross-reference with the Masterpact MT catalog to confirm the MT06N1 frame reference matches your installation. If in doubt, contact TOPNLMS with your existing breaker nameplate data for pre-purchase compatibility confirmation.

Q4: What is the recommended inventory strategy for the MT06N1 in a critical facility?
For facilities with multiple Masterpact MT feeders, maintaining a minimum of one spare MT06N1 per switchgear lineup is recommended. For continuous-process plants or facilities with no redundant feeders, a two-unit buffer stock is advisable. Pair the spare MT06N1 with a compatible Micrologic trip unit and MN/MX coil accessories to ensure a complete replacement kit is available for immediate deployment during an unplanned outage.

Quick Inquiry

Click Quote This Model and the Part Number field will auto-fill with MT06N1.