Schneider Electric MT40N1 Original Industrial Spare Compact NS Compatible
MT40N1Schneider Electric MT40N1 Compact NS MCCB — original industrial spare. Fast replacement, system compatibility guaranteed. 12-month warranty. Ships globally.
Request availability, condition, lead time and export shipping details for iC65N 1P C1A.
Send this exact part number, quantity and destination country. TOPNLMS will confirm availability, condition and export lead time before quotation.
When your existing Schneider Electric iC65N 1P C1A miniature circuit breaker reaches end-of-service life, shows signs of thermal fatigue, or becomes unavailable through standard distribution channels, a controlled replacement strategy is essential to maintaining the integrity of your low-voltage distribution panel. The iC65N 1P C1A is a single-pole, 1 A, C-curve MCB from Schneider Electric’s Acti9 iC65 series — a platform widely deployed across industrial control cabinets, MCC panels, PLC power distribution assemblies, and building automation switchboards. This replacement solution is designed to restore full protection functionality with zero compromise on safety ratings, breaking capacity, or DIN-rail footprint.
The iC65N series is rated at 6 kA breaking capacity (IEC 60947-2), operates on 230/400 V AC systems, and occupies a standard 18 mm DIN-rail module width per pole. The C-curve characteristic (tripping between 5× and 10× rated current) makes the iC65N 1P C1A ideal for protecting resistive and slightly inductive loads — including 24 VDC SMPS power supplies, PLC I/O bus power rails, signal conditioning modules, and low-power motor starter auxiliary circuits. When replacing a failed or aging unit, engineers must verify that the replacement maintains the same curve, pole count, rated current, and breaking capacity to preserve the original protection coordination study.
| Parameter | Legacy / Outgoing Unit | Replacement: iC65N 1P C1A |
|---|---|---|
| SKU / Model | iC65N 1P C1A (aged / failed unit) | iC65N 1P C1A (new, tested) |
| Pole Configuration | 1P (Single Pole) | 1P (Single Pole) |
| Rated Current | 1 A | 1 A |
| Trip Curve | C-curve (5–10× In) | C-curve (5–10× In) |
| Breaking Capacity | 6 kA @ 230/400 V AC | 6 kA @ 230/400 V AC (IEC 60947-2) |
| Mounting | 35 mm DIN rail | 35 mm DIN rail — direct drop-in |
| Module Width | 18 mm (1 module) | 18 mm (1 module) — no panel re-layout |
| Terminal Type | Screw clamp, top/bottom | Screw clamp, top/bottom — same wiring |
| Voltage Rating | 230/400 V AC, 50/60 Hz | 230/400 V AC, 50/60 Hz |
| Series Platform | Acti9 iC65 | Acti9 iC65 — full accessory compatibility |
| Auxiliary Accessories | OF, SD, iOF, iSD contacts | Compatible with all iC65 auxiliary contacts |
| Replacement Complexity | — | Direct swap — no rewiring, no re-labeling |
| Warranty | — | 12-Month Warranty (TOPNLMS) |
A single MCB replacement rarely occurs in isolation. In most industrial and commercial panel upgrade projects, the iC65N 1P C1A is one component within a broader Acti9 or Multi9 distribution assembly. During a planned retrofit or emergency replacement, site engineers typically need to address the surrounding infrastructure simultaneously to ensure system-wide reliability.
For panels where the iC65N feeds a 24 VDC SMPS — such as those powering a Schneider Electric Modicon M221 or M241 PLC CPU — it is common to also inspect or replace the adjacent iC65N 2P C6A or iC65N 2P C10A breakers that protect the main AC input to the power supply. If the panel includes a Schneider Electric iID 2P 25A 30mA RCCB (residual current circuit breaker) upstream of the MCB group, its mechanical condition and trip test results should be verified as part of the same maintenance window.
In control cabinets housing Schneider Electric TeSys D or TeSys K motor starters, the iC65N 1P C1A is frequently used to protect the coil supply circuit of LC1D contactors. Replacing the MCB without inspecting the LC1D09 or LC1D12 contactor contacts for wear is a missed opportunity to reduce future unplanned downtime. Similarly, if the panel uses a Schneider Electric Acti9 iC60N series breaker in an adjacent feeder position, confirming that the iC60N and iC65N accessories (auxiliary contacts, shunt trips) remain interchangeable under the current panel design is a necessary step before closing the cabinet.
For panels with remote monitoring requirements, the iC65N can be paired with a Schneider Electric iOF auxiliary contact block to provide open/close status feedback to a SCADA system or building management controller. If the existing wiring harness uses a Schneider Electric A9A26924 or equivalent OF contact, the replacement iC65N 1P C1A accepts the same snap-on accessory without modification. In larger distribution boards where a Schneider Electric Acti9 Active iQuick system or a PowerTag energy sensor is installed, the physical replacement of the iC65N does not affect the energy metering topology, as the PowerTag clamps onto the outgoing cable rather than the breaker body itself.
When the retrofit scope extends to the PLC control panel itself — for example, migrating from a legacy Modicon TSX Micro or Quantum platform to a current-generation Modicon M580 ePAC — the low-voltage distribution design must be revisited. The M580 CPU and its BME XBP backplane modules draw different inrush and steady-state currents compared to older Quantum 140 CPU modules, and the upstream MCB sizing must be recalculated accordingly. In such migration projects, the iC65N 1P C1A typically remains appropriate for protecting individual 24 VDC auxiliary supply branches, while higher-rated iC65N 1P C6A or iC65N 1P C10A units may be required for the main DC bus protection.
Q: Can I replace the iC65N 1P C1A without rewiring the panel?
A: Yes. The replacement unit is dimensionally identical — same 18 mm DIN-rail width, same screw-clamp terminal positions, and same top/bottom cable entry. Existing cable ferrules and labels do not need to be changed.
Q: Will the existing iC65 auxiliary contacts (OF, SD, iOF) fit the replacement breaker?
A: Yes. All Acti9 iC65 series snap-on accessories are compatible across the iC65N product range. No accessory replacement is required unless the accessories themselves are damaged.
Q: Does replacing the MCB affect the upstream RCCB coordination?
A: No, provided the replacement unit has the same rated current and trip curve. The protection coordination between the iC65N 1P C1A and an upstream iID or iDPN RCCB is determined by the current rating and curve, not the physical unit serial number.
Q: Is the iC65N 1P C1A compatible with Schneider Electric’s Acti9 busbar systems?
A: Yes. The iC65N 1P C1A is compatible with Acti9 comb busbars (1P, 2P, 3P configurations) and pitch-18 distribution blocks used in Pragma and Kaedra enclosures.
Q: What communication protocol considerations apply when this MCB protects a PLC power supply?
A: The MCB itself is not a communicating device. However, if the protected load is a PLC CPU or communications module (e.g., a Modicon M340 BMX NOE Ethernet module or a Profibus DP head module), an unplanned trip will cause a network node loss. Replacing the MCB during a scheduled maintenance window — rather than after a fault — eliminates unplanned protocol interruptions.
Q: How do I verify the replacement unit before installation?
A: Each unit shipped by TOPNLMS is visually inspected and function-tested prior to dispatch. We recommend a manual trip test (using the test button if present, or a calibrated test set) after installation and before energizing the load.
Every Schneider Electric iC65N 1P C1A unit supplied by TOPNLMS is covered by a 12-Month Warranty from the date of shipment. Our pre-shipment process includes visual inspection for mechanical integrity, label verification against the declared SKU, and a functional continuity check. Units that do not pass inspection are quarantined and not dispatched.
In the event of a warranty claim, TOPNLMS provides a replacement unit or full refund within the warranty period, subject to inspection of the returned item. Our after-sales response target is 24 hours for initial acknowledgment and 5 business days for resolution. We maintain buffer stock of high-rotation Acti9 iC65 series SKUs to support rapid replacement dispatch without lead-time delays.
For procurement teams managing MRO (maintenance, repair, and operations) inventory, TOPNLMS can provide batch testing certificates, packing lists with individual serial numbers, and export documentation for cross-border shipments. We ship from Xiamen, China, with DHL Express, FedEx International Priority, and sea freight options available depending on order volume and urgency.
Contact our technical sales team to confirm stock availability, request a quotation, or discuss volume pricing for panel builders and system integrators.
Click Quote This Model and the Part Number field will auto-fill with iC65N 1P C1A.