Schneider ABE7H16R11 Replacement for Telefast 2
ABE7H16R11ABE7H16R11 Telefast 2 16-ch relay interface module. Drop-in replacement, wiring-compatible, 12-month warranty. Fast global shipping from TOPNLMS.
Request availability, condition, lead time and export shipping details for BMXNOM0200.
Send this exact part number, quantity and destination country. TOPNLMS will confirm availability, condition and export lead time before quotation.
The Schneider Electric BMXNOM0200 is the CANopen Network Master Module designed for the Modicon M340 PLC platform. For facilities running aging Modicon Quantum, Modicon Premium, or early-generation M340 architectures, the BMXNOM0200 represents a proven, low-disruption upgrade path that preserves existing CANopen field device wiring, network topology, and control logic with minimal re-engineering effort.
Industrial sites that have relied on legacy CANopen master modules — including discontinued variants from the TSX and Quantum families — frequently encounter obsolescence challenges: end-of-life support, unavailable spare parts, and rising downtime risk. The BMXNOM0200 slots directly into the BMX XBP ••00 backplane rack (4-slot, 8-slot, or 12-slot configurations), occupying a standard M340 module bay without requiring cabinet re-layout or additional DIN rail space. Its compact form factor is fully compatible with existing M340 power supply modules such as the BMXCPS2000 and BMXCPS3500, ensuring no power budget recalculation is needed during the swap.
From a communications standpoint, the BMXNOM0200 operates as a CANopen master (NMT master) supporting up to 63 slave nodes at baud rates from 10 kbps to 1 Mbps. Facilities migrating from older Modicon TSX Premium CANopen interfaces will find that existing DS301/DS401 device profiles, PDO/SDO configurations, and node addressing schemes transfer directly — dramatically reducing re-commissioning time on the plant floor. The module integrates natively with Unity Pro (now EcoStruxure Control Expert) programming software, so existing Structured Text, Ladder Diagram, or Function Block programs require no protocol-layer rewriting.
During a typical retrofit, engineers replacing a failed or end-of-life CANopen master will also evaluate adjacent modules in the same rack. The BMXNOE0100 Ethernet communication module and BMXNOE0110 are commonly installed alongside the BMXNOM0200 to provide simultaneous Modbus TCP/IP supervisory connectivity, enabling hybrid network architectures where CANopen handles field-level I/O while Ethernet manages SCADA integration. For analog signal acquisition, the BMXAMI0810 8-channel analog input module and BMXAMO0410 analog output module are standard companions in M340 panels handling process control loops.
Wiring compatibility is a critical factor in any brownfield upgrade. The BMXNOM0200 uses a standard 9-pin SUB-D CANopen connector, which is physically and electrically identical to the connectors used on most existing Schneider CANopen field devices — including Altivar drive series frequency inverters such as the ATV312 and ATV61, which are widely deployed as CANopen slaves in motor control centers. This means existing shielded twisted-pair CANopen cables, termination resistors, and node connectors can be reused without modification, eliminating a major source of retrofit cost and error.
For digital I/O expansion during the migration, the BMXDDI1602 16-channel discrete input module and BMXDDO1602 discrete output module are direct rack companions that share the same backplane bus, simplifying I/O mapping in the Unity/EcoStruxure environment. If the existing cabinet includes a BMXP342020 or BMXP342030 M340 CPU, the BMXNOM0200 is fully validated for use with these processors under standard Schneider firmware revisions, with no special licensing or firmware upgrade required.
Physical installation follows the standard M340 module insertion procedure: power down the rack, align the module with the backplane connector, press firmly until the locking tab engages, and restore power. No tools are required. The module is recognized automatically by the CPU upon boot, and the CANopen network configuration is restored from the Unity/EcoStruxure project file — making the entire hot-swap process achievable within a planned maintenance window of under two hours for experienced engineers.
| Parameter | Legacy / Replaced Module | BMXNOM0200 (Replacement) |
|---|---|---|
| Platform | Modicon TSX Premium / Quantum CANopen | Modicon M340 |
| Protocol | CANopen (DS301) | CANopen Master (DS301/DS401, NMT) |
| Max Slave Nodes | Varies (typically 32–63) | 63 nodes |
| Baud Rate | Up to 1 Mbps | 10 kbps – 1 Mbps |
| Connector | 9-pin SUB-D | 9-pin SUB-D (direct reuse) |
| Rack Compatibility | TSX / Quantum backplane | BMX XBP ••00 (M340 backplane) |
| Programming Software | PL7 Pro / Concept | Unity Pro / EcoStruxure Control Expert |
| Installation | Tool-required in some models | Tool-free, locking tab |
| Power Supply Compatibility | Dedicated PSU per platform | BMXCPS2000 / BMXCPS3500 |
| Replacement Recommendation | End-of-life / discontinued | Direct upgrade, no re-wiring required |
| Warranty | N/A (legacy) | 12-Month Warranty (TOPNLMS) |
A successful M340 CANopen migration rarely involves a single module swap. In practice, engineers sourcing the BMXNOM0200 also evaluate the surrounding rack and cabinet components to ensure system-wide compatibility. The BMXP342020 M340 CPU is the most common host processor for this module, and pairing it with the BMXNOE0100 Ethernet module creates a dual-network architecture that supports both CANopen field devices and Modbus TCP/IP SCADA connectivity simultaneously.
For motor control integration, Altivar ATV312 and ATV61 variable frequency drives configured as CANopen slaves connect directly to the BMXNOM0200 network without gateway hardware, preserving existing drive parameter files and speed reference mappings. Analog process signals are typically handled by the BMXAMI0810 input module, while discrete safety interlocks route through the BMXDDI1602. Where signal isolation is required between field instruments and the M340 rack — particularly in high-noise environments such as motor control centers — DIN-rail signal isolators or loop-powered barriers are inserted at the terminal block level, compatible with the M340’s standard I/O wiring conventions.
For programming and commissioning, a standard USB-to-mini-USB cable or the TSXPCX3030 programming cable supports direct CPU connection during the migration validation phase, allowing engineers to verify CANopen node status, PDO mapping, and network health before returning the system to production.
Q: Can I reuse existing CANopen field wiring when replacing a legacy Schneider CANopen master with the BMXNOM0200?
A: Yes. The BMXNOM0200 uses the same 9-pin SUB-D CANopen connector and supports the same DS301 device profile as legacy Schneider CANopen masters. Existing shielded twisted-pair cables, termination resistors, and node connectors can be reused without modification.
Q: Do I need to rewrite my PLC program when migrating from PL7 Pro or Concept to Unity Pro / EcoStruxure Control Expert?
A: The CANopen network configuration (node addresses, PDO/SDO mappings, baud rate) must be re-entered in EcoStruxure Control Expert. However, the control logic itself — Ladder, ST, or FBD — can be manually ported. Schneider provides migration guides for PL7 Pro → Unity Pro transitions.
Q: Will the BMXNOM0200 fit in my existing M340 cabinet without modification?
A: Yes. The module occupies one standard M340 backplane slot (BMX XBP ••00 series). No additional DIN rail space, cable ducts, or cabinet modifications are required.
Q: What CPU firmware version is required for BMXNOM0200 compatibility?
A: The BMXNOM0200 is compatible with M340 CPUs (BMXP342020, BMXP342030, BMXP3420302) running standard Schneider firmware. No special firmware upgrade is required for basic CANopen master operation.
Q: How long does a typical BMXNOM0200 replacement take on-site?
A: Physical module swap takes under 15 minutes. Full network re-commissioning — including node verification, PDO mapping confirmation, and functional test — typically requires 1–2 hours depending on network size and site conditions.
Q: Is the BMXNOM0200 compatible with third-party CANopen slave devices (non-Schneider)?
A: Yes. The module complies with the CANopen DS301 standard and is interoperable with any certified CANopen slave device, including drives, sensors, encoders, and I/O blocks from third-party manufacturers.
Every BMXNOM0200 unit shipped by TOPNLMS is covered by a 12-month warranty from the date of delivery. Prior to shipment, each module undergoes functional verification including power-on self-test, communication port inspection, and visual quality check to ensure it meets operational standards.
In the event of a confirmed hardware defect within the warranty period, TOPNLMS provides replacement support with priority processing. Our technical team is available to assist with pre-shipment compatibility verification, installation guidance, and post-installation troubleshooting to minimize your system downtime.
We maintain ready stock of the BMXNOM0200 and related M340 components in our Xiamen warehouse, enabling same-day or next-business-day dispatch for urgent replacement orders. Express international shipping is available to most industrial regions.
For procurement inquiries, bulk pricing, or technical pre-sales support, contact our team directly:
📧 [email protected]
📞 +86 18359293191
Click Quote This Model and the Part Number field will auto-fill with BMXNOM0200.