Schneider BMXNOM0200 Replacement Solution for Modicon M340
BMXNOM0200BMXNOM0200 CANopen Network Master Module for Modicon M340. Drop-in replacement, upgrade compatibility, fast shipping, 12-month warranty. Schneider Electric.
Request availability, condition, lead time and export shipping details for 140NOE77111.
Send this exact part number, quantity and destination country. TOPNLMS will confirm availability, condition and export lead time before quotation.
The Schneider Electric 140NOE77111 is a dedicated Ethernet TCP/IP communication module engineered for the Modicon Quantum PLC platform — one of the most widely deployed process automation architectures in heavy industry, utilities, oil & gas, and manufacturing. As legacy Quantum systems age and original communication modules reach end-of-life, the 140NOE77111 remains the definitive drop-in replacement that preserves your existing control architecture while restoring full network connectivity without reprogramming, rewiring, or rack redesign.
For facilities running Modicon Quantum controllers such as the 140CPU65160 or 140CPU67160, maintaining reliable Ethernet TCP/IP communication is non-negotiable. A failed or degraded NOE module can isolate an entire PLC rack from the SCADA network, disrupt Modbus TCP polling cycles, and trigger unplanned shutdowns. Stocking a verified replacement 140NOE77111 is the most cost-effective insurance against this scenario.
| Parameter | Legacy / Outgoing Module | 140NOE77111 (This Unit) |
|---|---|---|
| Part Number | 140NOE77100 / 140NOE77101 | 140NOE77111 |
| Platform | Modicon Quantum | Modicon Quantum |
| Communication Protocol | Ethernet TCP/IP, Modbus TCP | Ethernet TCP/IP, Modbus TCP, FTP, HTTP |
| Network Speed | 10 Mbps | 10/100 Mbps Auto-negotiation |
| Connector Type | RJ45 | RJ45 (direct swap) |
| Rack Slot Compatibility | Quantum backplane (any slot) | Quantum backplane (any slot) |
| Power Supply Requirement | Supplied via backplane (140CPS11100 / 140CPS21100) | Supplied via backplane (same PSU compatible) |
| Programming Software | Unity Pro / Concept | Unity Pro / EcoStruxure Control Expert |
| IP Address Configuration | DIP switch / software | Software (Unity Pro / rotary switch) |
| Simultaneous Connections | Up to 16 | Up to 64 |
| Web Server / Diagnostics | Limited / None | Built-in HTTP web server |
| Replacement Recommendation | Direct replacement — no rack modification required | ✔ Confirmed drop-in upgrade |
| Warranty | — | 12-Month Warranty |
Migrating from an older NOE module or refreshing an aging Quantum rack is rarely a single-component exercise. In practice, a successful upgrade of the 140NOE77111 involves a coordinated review of the surrounding hardware to ensure the entire communication chain performs reliably after the swap.
Begin with the Quantum backplane power supply. Units such as the 140CPS11100 or 140CPS21100 supply regulated DC power to every module in the rack. If the power supply has been in continuous service for more than five years, its capacitors and output rails should be load-tested before commissioning the new NOE module. A marginal PSU can cause intermittent communication faults that are easily misdiagnosed as a module defect.
Next, inspect the Quantum CPU module — typically a 140CPU65160 or 140CPU67160 — to confirm firmware compatibility with the 140NOE77111. EcoStruxure Control Expert (formerly Unity Pro) may require a firmware update on the CPU before the new NOE module is recognized correctly on the backplane. This is a non-intrusive update that can be performed while the rack is powered, minimizing downtime.
For sites using Modbus Plus alongside Ethernet, the 140NOM21100 Modbus Plus Network Option Module may be present in the same rack. Verify that the NOE and NOM modules are assigned non-conflicting network addresses and that the Unity Pro project correctly maps both communication paths. Replacing the NOE without auditing the NOM configuration is a common source of post-upgrade communication errors.
If the Quantum rack interfaces with remote I/O drops via RIO coaxial cable, the 140CRP93200 Remote I/O Head Adapter should be inspected for cable termination integrity and module health. A degraded RIO head adapter can introduce latency on the backplane that affects NOE polling performance, even though the fault appears to originate from the Ethernet module.
On the field wiring side, review the 140ACI04000 analog input modules and 140DDI35300 discrete input modules connected to the same rack. During the NOE replacement window, it is efficient to verify terminal block seating, check for corroded connections on 140XTS00200 terminal strip adapters, and confirm that all I/O module status LEDs are green before restoring network communication.
For facilities that use Vijeo Citect or Wonderware InTouch SCADA systems communicating via Modbus TCP to the Quantum rack, the 140NOE77111’s expanded 64-connection capacity means you can add additional SCADA clients, historian servers, or OPC-DA gateways without replacing the module again. This is a meaningful upgrade over the 16-connection limit of earlier NOE variants.
Finally, if the control cabinet houses a Magelis HMIGTO or HMISCU panel connected to the Quantum CPU via Ethernet, confirm that the HMI’s Ethernet driver is configured for Modbus TCP and that the IP addressing scheme is updated to reflect the new NOE module’s address. This step is frequently overlooked during rushed replacements and results in HMI communication loss after the upgrade is otherwise complete.
All units supplied by TOPNLMS are tested for backplane communication, Ethernet link establishment, and LED diagnostic response prior to shipment. Each 140NOE77111 is dispatched with full ESD packaging and a 12-month warranty covering manufacturing defects and functional failure under normal operating conditions.
Q1: Can the 140NOE77111 replace a 140NOE77100 or 140NOE77101 without modifying the Unity Pro project?
In most cases, yes. The 140NOE77111 occupies the same rack slot and uses the same Modbus TCP driver within Unity Pro. However, you should verify the module DTM (Device Type Manager) version in your Unity Pro project. If the project was built with an older NOE DTM, updating to the current DTM version before swapping the module ensures full feature compatibility, including the web server and expanded connection table.
Q2: Does the 140NOE77111 support both Modbus TCP and EtherNet/IP simultaneously?
The 140NOE77111 natively supports Modbus TCP, FTP, HTTP, and SNMP over standard Ethernet TCP/IP. It does not natively support EtherNet/IP (CIP). If your upgrade path requires EtherNet/IP connectivity, a protocol gateway such as the ProSoft MVI56E-MNET or a dedicated EtherNet/IP scanner module should be evaluated as part of the migration plan.
Q3: What is the physical installation procedure for replacing an existing NOE module in a live Quantum rack?
The Quantum platform supports hot-swap of communication modules in most configurations, but this depends on the CPU firmware version and the Unity Pro project settings. Best practice is to place the CPU in STOP mode, remove the old NOE module, insert the 140NOE77111, power-cycle the rack, and then restore the CPU to RUN mode. IP address configuration via the rotary switches or Unity Pro should be completed before insertion to minimize configuration time on the floor.
Q4: What warranty and post-sale support does TOPNLMS provide for the 140NOE77111?
Every 140NOE77111 supplied by TOPNLMS carries a 12-month warranty from the date of shipment. Pre-shipment testing includes backplane power-up verification, Ethernet port link test, and LED diagnostic check. In the event of a confirmed functional defect within the warranty period, TOPNLMS provides replacement dispatch or full refund. Technical support for installation and compatibility questions is available via email at [email protected] or by phone at +86 18359293191.
TOPNLMS supplies the Schneider Electric 140NOE77111 with a comprehensive 12-month warranty covering all functional defects under normal industrial operating conditions. Every unit undergoes pre-shipment inspection including power-on verification, Ethernet link establishment test, and backplane communication check. Units are dispatched in anti-static ESD bags with protective foam packaging suitable for international freight.
Replacement or refund is processed within 5 business days of confirmed defect verification. Our technical team is available to assist with compatibility questions, Unity Pro configuration guidance, and installation support throughout the warranty period. For urgent replacement requirements, expedited shipping options are available to minimize control system downtime.
Purchase with confidence knowing that every 140NOE77111 from TOPNLMS is sourced from verified supply channels, tested before dispatch, and backed by responsive after-sales support.
Click Quote This Model and the Part Number field will auto-fill with 140NOE77111.