Schneider Electric BMXDDO1602 Ruggedized Output Module
BMXDDO1602Buy Schneider Electric BMXDDO1602 16-Ch 24VDC NPN transistor output module for Modicon M340 PLC. Ruggedized, EMI-resistant, 12-month warranty. In stock.
Request availability, condition, lead time and export shipping details for 140ACO13000.
Send this exact part number, quantity and destination country. TOPNLMS will confirm availability, condition and export lead time before quotation.
The Schneider Electric 140ACO13000 is an 8-channel, 12-bit analog output module designed for the Modicon Quantum PLC platform. As legacy Quantum systems approach end-of-life and spare parts become increasingly scarce, plant engineers and system integrators face mounting pressure to source verified replacement units or plan a structured migration path. This page provides a complete technical and procurement reference for facilities transitioning from discontinued or aging Quantum analog output infrastructure to a reliable, tested 140ACO13000 replacement — with minimal disruption to ongoing operations.
The 140ACO13000 outputs voltage or current signals (0–10 V / 4–20 mA selectable per channel) and mounts directly into the standard Modicon Quantum backplane, including the 140XBP01600 and 140XBP00600 rack assemblies. Its 12-bit resolution ensures precise process control in applications such as variable-speed drive command, valve positioner control, and PID loop output — all common in petrochemical, water treatment, and discrete manufacturing environments.
| Parameter | 140ACO13000 (This Unit) | Typical Legacy / Alternate |
|---|---|---|
| Platform | Modicon Quantum | Modicon Quantum / Premium |
| Channels | 8 CH Analog Output | 4–8 CH (varies by model) |
| Resolution | 12-bit | 12-bit / 13-bit |
| Output Signal | 0–10 V / 4–20 mA | 0–10 V / 4–20 mA |
| Backplane Slot | Standard Quantum I/O slot | Standard Quantum I/O slot |
| Communication | Modbus Plus / Ethernet via CPU | Modbus Plus / Ethernet |
| Power Supply | Supplied via backplane (140CPS11100 / 140CPS21100) | Backplane-powered |
| Wiring Connector | 40-pin removable terminal block | 40-pin removable terminal block |
| Programming | Unity Pro / Control Expert compatible | Concept / ProWORX / Unity Pro |
| Replacement Fit | Direct drop-in for 140ACO13000 | Requires I/O map re-addressing if changing model |
| Warranty | 12 Months | N/A (end-of-life / used) |
A successful 140ACO13000 migration rarely involves a single module swap. In most Quantum-based control cabinets, the analog output module works in close coordination with several other components that may also require attention during the upgrade window.
On the input side, the 140ACI04000 (8-channel analog input module) is frequently installed in adjacent slots and shares the same terminal block wiring standard — verifying its calibration status during the same maintenance window avoids a second shutdown. For digital I/O, the 140DDO35300 discrete output module and 140DDI35300 discrete input module occupy the same Quantum rack and should be inspected for contact wear if the system has been in service for more than five years.
The 140CPU65160 or 140CPU67160 Quantum CPU modules govern I/O scanning and Modbus Plus communication. If the CPU firmware is below the version required for Unity Pro / Control Expert compatibility, a firmware update or CPU replacement should be scheduled alongside the analog output module swap to ensure consistent behavior across the I/O map. Communication to SCADA or DCS layers typically passes through the 140NOE77101 Ethernet communication module — confirming its IP configuration and Modbus TCP mapping before the cutover prevents post-installation communication faults.
Power integrity is critical. The 140CPS11100 or 140CPS21100 power supply modules feed the backplane; a failing power supply can cause intermittent analog output drift that is easily misdiagnosed as a module fault. Replacing or bench-testing the power supply in parallel with the 140ACO13000 swap eliminates this variable. For larger racks, the 140XBP01600 16-slot backplane provides expansion capacity if additional I/O modules are being added as part of the modernization scope.
Field wiring connects to the module via a 40-pin removable terminal block. If the existing terminal block shows signs of oxidation or loose contacts — common in humid or coastal industrial environments — replacing it with a new block during the module swap eliminates a latent fault source without requiring any re-wiring of field cables. For installations where signal isolation is required between the PLC output and the field device (e.g., variable-frequency drives with high common-mode noise), a signal isolator / repeater inserted between the terminal block and the drive input provides an additional layer of protection and is strongly recommended in retrofit scenarios.
Q: Is the 140ACO13000 a direct drop-in replacement without software changes?
A: Yes, provided the replacement unit occupies the same rack slot and the I/O address in the Unity Pro / Control Expert project remains unchanged. No logic modifications are required for a like-for-like swap.
Q: Can I use this module with the older Concept or ProWORX programming environment?
A: The 140ACO13000 hardware is compatible with Concept-era Quantum systems. However, Schneider Electric has ended support for Concept software; migrating the project to Control Expert (formerly Unity Pro) is strongly recommended before the next major maintenance cycle.
Q: What communication protocols does this module support?
A: The module communicates via the Quantum backplane bus. System-level communication (Modbus Plus, Modbus TCP/IP, or PROFIBUS depending on the CPU and network module installed) is managed by the CPU and communication modules — the 140ACO13000 itself does not require separate protocol configuration.
Q: How do I verify wiring compatibility before installation?
A: The 40-pin terminal block pinout is identical across all 140ACO-series modules. Refer to the existing field wiring diagram and confirm channel-to-pin assignments against the 140ACO13000 installation guide (Schneider document 840USE10000). No re-wiring is required for a direct replacement.
Q: What is the physical installation space requirement?
A: The module occupies one standard Quantum I/O slot (single-width). No additional panel space is required beyond the existing slot vacancy.
Every 140ACO13000 unit shipped by TOPNLMS is covered by a 12-month replacement warranty from the date of delivery. Prior to dispatch, each module undergoes functional verification including channel output accuracy testing across the full 0–10 V and 4–20 mA ranges, backplane connector inspection, and firmware version confirmation. Units are packed in anti-static ESD bags with foam cushioning to prevent transit damage.
If a unit exhibits any fault within the warranty period — including output drift, channel failure, or communication errors attributable to the module — TOPNLMS will arrange a replacement shipment at no additional cost. Our technical support team responds to after-sales inquiries within one business day. For urgent production-down situations, expedited shipping options are available upon request.
We maintain stock of the 140ACO13000 and related Quantum-series components to support rapid fulfillment for both single-unit emergency replacements and multi-unit project orders. Lead times and current stock levels are confirmed at the time of order.
Click Quote This Model and the Part Number field will auto-fill with 140ACO13000.