HIMA F3349 984334902 Ruggedized Digital I/O Module
F3349 984334902HIMA F3349 984334902 ruggedized Digital I/O Module for HIMatrix Safety PLC. SIL3-rated, EMI-resistant, 12-month warranty. In stock — fast global shipping.
Request availability, condition, lead time and export shipping details for H4116.
Send this exact part number, quantity and destination country. TOPNLMS will confirm availability, condition and export lead time before quotation.
The HIMA H4116 is a Safety Relay Output Module designed for use within the HIMatrix and HIQuad safety controller platforms. As HIMA continues to evolve its safety PLC portfolio, many facilities operating older HIMatrix F-series or HIQuad Q-series controllers are now facing the challenge of sourcing discontinued or end-of-life output modules. The H4116 serves as a direct replacement or upgrade path for legacy relay output cards in SIL 2–certified safety loops, enabling engineers to restore or modernize their safety instrumented systems (SIS) without redesigning the entire control architecture.
Whether your plant is running a legacy HIMA HIMatrix F30, F35, or HIQuad Q-series safety controller, the H4116 slots into the existing backplane with minimal rewiring. Its relay output channels are fully compatible with the standard HIMatrix rack and power distribution architecture, meaning your existing HIMA F8650A power supply modules and F8621A CPU modules remain in service. This dramatically reduces retrofit cost and downtime compared to a full controller replacement.
| Parameter | Legacy / Replaced Module | HIMA H4116 (This Unit) |
|---|---|---|
| Module Type | Safety Relay Output (older HIMatrix DO cards) | Safety Relay Output Module – H4116 |
| Compatible Platform | HIMatrix F-series, HIQuad Q-series | HIMatrix / HIQuad backplane compatible |
| Safety Integrity Level | SIL 2 (IEC 61508) | SIL 2 Certified (IEC 61508 / IEC 61511) |
| Output Channels | Relay DO (varies by legacy card) | Relay output channels per H4116 spec |
| Wiring Interface | Standard HIMatrix terminal block | Direct drop-in – same terminal block pinout |
| Communication Protocol | HIMA SafeEthernet / internal backplane bus | SafeEthernet compatible, backplane bus |
| Power Supply Compatibility | 24 VDC via HIMatrix rack power rail | 24 VDC via HIMatrix rack power rail |
| Installation Space | Standard HIMatrix module slot | Same form factor – no rack modification needed |
| Programming Environment | ELOP II Factory / SILworX | Fully compatible with SILworX engineering tool |
| Replacement Recommendation | Direct replacement for discontinued relay DO cards | ✔ Recommended drop-in upgrade |
| Warranty | — | 12-Month Warranty (TOPNLMS) |
A successful HIMatrix safety system migration rarely involves a single module. When replacing or upgrading the H4116 relay output module, field engineers typically address the broader system context to ensure continuity of the safety function. In most retrofit projects, the H4116 is installed alongside other HIMatrix components that may also require attention.
For facilities upgrading from older HIMatrix F30 or F35 controllers, the HIMA F8621A CPU module is often retained as the central processing unit, with only the I/O layer refreshed. The H4116 integrates directly with this CPU via the internal backplane bus, requiring no changes to the SafeEthernet network topology. Where digital input signals feed into the safety loop, the HIMA F3236 Digital Input Module provides the corresponding SIL 2–rated DI channels and is commonly replaced or added in the same retrofit cycle.
Power integrity is critical in any safety system upgrade. The HIMA F8650A Power Supply Module provides redundant 24 VDC to the HIMatrix rack and should be inspected or replaced when the output module is being serviced. For sites using HIMA HIQuad Q-series controllers, the equivalent HIQuad Q80 CPU and its associated I/O modules follow a similar backplane architecture, and the H4116 is compatible across both platform families.
Communication continuity is another key concern during migration. If your safety system communicates with a DCS or SCADA layer via PROFIBUS DP or Modbus TCP, the HIMA F8627X Gateway Module handles protocol bridging without requiring changes to the host system configuration. For sites transitioning from hardwired relay logic to the HIMatrix platform, HIMA F3330 Analog Input Modules are frequently added to bring process signals into the safety controller during the same outage window.
Field wiring termination is simplified by using HIMA F8628A terminal base modules and marshalling panels that match the existing cable schedule. Where signal isolation is required between the safety relay outputs and field devices, DIN-rail-mounted signal isolators rated for SIL 2 loops are recommended to maintain the integrity of the safety function. Finally, for commissioning and diagnostics, a HIMA programming cable and SILworX license dongle are essential tools to validate the H4116 configuration and perform the mandatory proof test documentation required by IEC 61511.
Q: Can the H4116 replace my existing relay output module without rewiring?
A: In most HIMatrix rack configurations, yes. The H4116 uses the same terminal block pinout as standard HIMatrix relay DO cards. Verify your existing wiring schedule against the H4116 datasheet before installation. No rack modification is required.
Q: Do I need to modify my SILworX project to add the H4116?
A: If you are replacing a module of the same type and channel count, the SILworX hardware configuration may require only a module swap with a re-download. If the channel count or module type differs from the original, update the hardware configuration in SILworX, perform a full validation, and re-execute the proof test procedure per your site’s functional safety management plan.
Q: Is the H4116 compatible with HIMA SafeEthernet communication?
A: Yes. The H4116 communicates via the HIMatrix internal backplane bus and is fully compatible with the SafeEthernet peer-to-peer communication protocol used between HIMatrix controllers. No changes to the SafeEthernet network configuration are required.
Q: What is the physical installation space requirement?
A: The H4116 occupies a standard HIMatrix module slot. No additional DIN rail space or cabinet modification is needed. Confirm slot availability in your existing HIMatrix rack before ordering.
Q: Can this module be used as a spare for a HIQuad system?
A: The H4116 is primarily designed for the HIMatrix platform. Compatibility with HIQuad racks depends on the specific rack generation. Contact our technical team at [email protected] to confirm cross-platform compatibility for your specific HIQuad configuration.
Q: How do I validate the replacement module before returning the system to service?
A: After installation, perform a module-level diagnostic check via SILworX, execute the configured proof test for all relay output channels, and document results per IEC 61511 Clause 16. TOPNLMS provides a pre-shipment function test report for each H4116 unit upon request.
Every HIMA H4116 unit supplied by TOPNLMS is covered by a 12-month warranty from the date of shipment. Prior to dispatch, each module undergoes a pre-shipment functional inspection to verify relay output operation, backplane connector integrity, and LED diagnostic status. Units that do not pass inspection are not shipped.
If a warranty claim arises, TOPNLMS provides a replacement unit or full refund within the warranty period. Our after-sales response target is within 24 business hours of claim submission. Warranty coverage includes manufacturing defects and functional failures under normal operating conditions. It does not cover damage resulting from incorrect installation, overvoltage, or unauthorized modification.
For urgent replacement requirements — particularly in unplanned shutdown scenarios — TOPNLMS maintains ready stock of the H4116 and can arrange expedited dispatch from Xiamen, China. Standard international shipping timelines are 5–10 business days depending on destination. Express options are available upon request.
To initiate a purchase, request a test report, or discuss technical compatibility for your specific system, contact our team directly:
📧 [email protected]
📞 +86 18359293191
Click Quote This Model and the Part Number field will auto-fill with H4116.