Allen-Bradley 80190-440-03-R Ruggedized I/O Interface Module
80190-440-03-RAllen-Bradley 80190-440-03-R Flex I/O Interface Module. Rugged, reliable, in stock. 12-month warranty. Fast global shipping. Contact: [email protected]
Request availability, condition, lead time and export shipping details for 1788-EN2DN.
Send this exact part number, quantity and destination country. TOPNLMS will confirm availability, condition and export lead time before quotation.
The Allen-Bradley 1788-EN2DN is a critical EtherNet/IP to DeviceNet Linking Device within Rockwell Automation’s 1788 Series, purpose-built for bridging modern Ethernet-based control networks with legacy DeviceNet field device layers. In industrial facilities where mixed-generation control architectures remain the operational backbone, the 1788-EN2DN serves as an indispensable gateway — enabling seamless data exchange between ControlLogix or CompactLogix PLCs and DeviceNet-connected sensors, drives, and actuators without requiring a full system overhaul.
For maintenance engineers and procurement teams managing aging automation infrastructure, sourcing a verified original 1788-EN2DN spare is not merely a replacement decision — it is a system stability investment. Unplanned downtime caused by a failed network gateway can cascade across an entire production line, halting DeviceNet device communication and triggering fault states in connected drives, I/O modules, and safety relays. Keeping a qualified spare on the shelf eliminates this risk and dramatically reduces mean time to repair (MTTR).
| Part Number | 1788-EN2DN |
| Brand / Manufacturer | Allen-Bradley (Rockwell Automation) |
| Series | 1788 Linking Device Series |
| Function | EtherNet/IP to DeviceNet Linking Device (Gateway) |
| EtherNet/IP Port | 10/100 Mbps, RJ-45, Full/Half Duplex |
| DeviceNet Port | 125 / 250 / 500 Kbps, 5-pin open-style connector |
| Max DeviceNet Nodes | Up to 63 nodes |
| Power Supply | 24V DC (±10%), external supply required |
| Power Consumption | Approx. 3.5 W |
| Operating Temperature | 0°C to 60°C (32°F to 140°F) |
| Storage Temperature | -40°C to 85°C |
| Humidity | 5% to 95% non-condensing |
| Enclosure Rating | IP20 (panel-mount, DIN rail compatible) |
| Weight | Approx. 1,400 g (with packaging) |
| Compatibility | ControlLogix, CompactLogix, SoftLogix; RSNetWorx for DeviceNet; Studio 5000 Logix Designer |
| Country of Origin | United States |
| Warranty | 12 Months — Tested and verified before shipment |
When a 1788-EN2DN is flagged for replacement during a scheduled shutdown or emergency repair, experienced maintenance teams treat the event as a broader inspection opportunity. The gateway sits at the intersection of the EtherNet/IP backbone and the DeviceNet field layer, meaning its failure often exposes underlying issues in adjacent components that share the same control cabinet or network segment.
During a 1788-EN2DN replacement, it is best practice to simultaneously inspect the 1756-EN2T EtherNet/IP communication module in the ControlLogix chassis, as both devices share the same Ethernet segment and a degraded EN2T can cause intermittent gateway faults that are misdiagnosed as 1788-EN2DN failures. Similarly, the 1756-DNB DeviceNet Bridge module — if present as a redundant or parallel path — should be verified for firmware currency and node table integrity.
On the DeviceNet field side, the replacement window is the right time to audit connected PowerFlex 40 or PowerFlex 400 variable frequency drives, which are common DeviceNet nodes in motor control centers. A drive with a degraded DeviceNet adapter card can generate excessive bus traffic that stresses the linking device. Alongside drives, inspect 1794-ADN or 1794-ADNK FLEX I/O DeviceNet adapters for loose terminal connections and verify that all node addresses remain within the configured scan list.
Power integrity is equally critical. The 1788-EN2DN requires a stable 24V DC supply, so the maintenance window should include a voltage check on the 1606-XLP power supply module or equivalent 24V DIN rail supply feeding the gateway. Voltage sag or ripple above specification is a leading cause of premature gateway failure. If the cabinet also houses a 1788-DNBO DeviceNet Bus-Off module or network termination resistors, verify their condition and resistance values (should read 60Ω between CAN_H and CAN_L with both terminators installed).
For facilities running Rockwell’s safety architecture, check the 1791DS-IB8XOBV4 Guard I/O DeviceNet Safety module or similar safety I/O nodes on the same DeviceNet trunk. Safety nodes are particularly sensitive to network timing disruptions caused by a failing gateway. Finally, review the 1585J-M8CBJM-2 DeviceNet drop cables and trunk connectors for insulation damage, corrosion, or improper termination — physical layer issues account for a significant proportion of DeviceNet communication faults that are incorrectly attributed to the gateway module itself.
The 1788-EN2DN has been a production-stable part for over a decade, and many facilities continue to rely on it precisely because replacing the entire DeviceNet infrastructure with a modern EtherNet/IP-native architecture is cost-prohibitive and operationally disruptive. The 1788-EN2DN allows these facilities to extend the service life of their DeviceNet field devices — including legacy photoelectric sensors, proximity switches, and pneumatic valve manifolds — while maintaining full integration with current ControlLogix and CompactLogix controller platforms.
For sites transitioning from older 1788-DNBO or standalone DeviceNet scanner configurations, the 1788-EN2DN provides a direct upgrade path that preserves existing node addressing, EDS files, and RSNetWorx configuration databases. This means replacement can be executed during a planned maintenance window without requiring a full recommissioning of the DeviceNet network — a significant operational advantage in facilities where DeviceNet node counts exceed 30 devices.
When the original 1788-EN2DN is no longer available through standard distribution channels, sourcing a verified original spare from a qualified industrial parts supplier ensures that firmware compatibility, hardware revision, and EMC certification remain aligned with the installed base. Counterfeit or grey-market substitutes frequently exhibit intermittent communication faults under load, which are difficult to diagnose and can cause production losses far exceeding the cost of a genuine spare.
All units supplied by TOPNLMS are individually tested for EtherNet/IP connectivity, DeviceNet node scanning, and power supply integrity prior to shipment. Each unit ships with a 12-month warranty covering manufacturing defects and functional failures under normal operating conditions.
Q1: Is this a genuine original Allen-Bradley 1788-EN2DN or a compatible substitute?
This is an original Allen-Bradley 1788-EN2DN sourced from verified industrial supply channels. Each unit retains its original Rockwell Automation part markings, hardware revision label, and factory firmware. No third-party modifications are made.
Q2: How is the unit tested before shipment?
Each 1788-EN2DN undergoes functional verification including EtherNet/IP port connectivity, DeviceNet bus communication at all three baud rates (125/250/500 Kbps), 24V DC power-on self-test, and LED status indicator validation. A test report is available upon request.
Q3: What is the warranty coverage and how do I make a claim?
All units carry a 12-month warranty from the date of shipment. Warranty covers functional failures under normal operating conditions. To initiate a claim, contact [email protected] with your order number and a description of the fault. Replacement or refund is processed within 5 business days of fault confirmation.
Q4: Can this unit replace a 1788-EN2DN with a different hardware revision?
In most cases, yes. The 1788-EN2DN hardware revisions are backward-compatible at the firmware and configuration level. RSNetWorx for DeviceNet and Studio 5000 Logix Designer will recognize the replacement unit using the same EDS file. If your application has specific firmware revision requirements, please contact us before ordering to confirm compatibility.
© 2026 TOPNLMS. All rights reserved.
Original Source: https://topnlms.com
Contact: [email protected] | +86 18359293191
Click Quote This Model and the Part Number field will auto-fill with 1788-EN2DN.