Siemens 6ES7921-5AK20-0AA0 S7-300 20-Pin Screw Connector
6ES7921-5AK20-0AA0Siemens 6ES7921-5AK20-0AA0 S7-300 20-pin screw front connector. Drop-in replacement, wiring-compatible upgrade. In stock, 12-month warranty, fast global shipping.
Request availability, condition, lead time and export shipping details for 6XV1440-2KH32.
Send this exact part number, quantity and destination country. TOPNLMS will confirm availability, condition and export lead time before quotation.
The Siemens 6XV1440-2KH32 is a 3.2-meter PROFIBUS/MPI/PPI OP communications cable engineered for direct integration into SIMATIC NET fieldbus architectures. As legacy Siemens programming cables and operator panel interfaces reach end-of-life or become increasingly difficult to source, the 6XV1440-2KH32 provides a verified drop-in replacement path that preserves existing wiring layouts, connector pinouts, and communication protocol stacks without requiring PLC program modifications or panel reconfiguration.
Industrial facilities running SIMATIC S7-300 or S7-400 controllers connected to OP7, OP17, TP170, or MP270 operator panels frequently encounter compatibility challenges when original cables fail or are discontinued. The 6XV1440-2KH32 resolves these challenges by maintaining full electrical and protocol compatibility with the RS-485-based PROFIBUS DP, MPI, and PPI physical layers. Engineers can swap the cable during a scheduled maintenance window—or even an unplanned shutdown—without modifying the hardware configuration in STEP 7 or TIA Portal.
When migrating from older SIMATIC NET cabling infrastructure, the 6XV1440-2KH32 pairs naturally with the CP 5611 or CP 5512 communication processors installed in the programming PC, ensuring that the MPI adapter interface remains recognized by the operating system and the STEP 7 project. Facilities that have already transitioned their programming environment to TIA Portal V16 or later will find that the cable’s 12 Mbit/s MPI bandwidth ceiling is fully sufficient for online monitoring, program download, and HMI variable exchange with the connected S7-300 rack.
In distributed I/O architectures where ET 200M or ET 200S remote I/O stations are connected via PROFIBUS DP, the 6XV1440-2KH32 serves as the local segment cable between the IM 153-2 interface module and the upstream DP master. Its shielded twisted-pair construction and 9-pin Sub-D connectors conform to EN 50170 PROFIBUS physical layer specifications, making it interchangeable with the earlier 6XV1440-2KH10 (1.0 m) and 6XV1440-2KH50 (5.0 m) variants when a 3.2-meter reach is required. The cable’s passive design means no firmware, no configuration file, and no additional licensing—plug in and communicate.
Control cabinet integrators retrofitting older Siemens panels will appreciate that the 6XV1440-2KH32 occupies the same physical footprint as its predecessors. The 9-pin female Sub-D connector on the OP/HMI side mates directly with the RS-485 port on TP177, TP270, and MP377 touch panels, while the male Sub-D connector interfaces with the MPI port on the S7-300 CPU 314, CPU 315-2 DP, or CPU 317-2 DP without adapter hardware. No additional bus termination resistors are required when the cable is used as a point-to-point MPI link between a single CPU and a single HMI device.
For sites managing a mixed fleet of Siemens drives and motion controllers, the 6XV1440-2KH32 also supports PPI communication with SIMATIC S7-200 CPUs (CPU 224, CPU 226) and the associated EM 277 PROFIBUS DP expansion module, enabling a single cable standard across both the legacy S7-200 segment and the newer S7-300 backbone. Drive technicians connecting SINAMICS G120 or MICROMASTER 440 frequency inverters via USS or PROFIBUS will recognize the cable’s role in the commissioning workflow when using STARTER or Drive ES software.
Procurement teams evaluating replacement options should note that the 6XV1440-2KH32 ships fully tested against Siemens SIMATIC NET cable specifications. Each unit undergoes continuity verification, shield integrity check, and connector retention force testing prior to dispatch. Stock is maintained in Xiamen and can be shipped globally within 2–5 business days via DHL Express or FedEx International Priority, with full tracking provided at the time of dispatch.
| Parameter | Legacy / Replaced Model | 6XV1440-2KH32 (This Unit) |
|---|---|---|
| Cable Length | Various (1.0 m, 5.0 m legacy variants) | 3.2 m |
| Connector Type (HMI Side) | 9-pin Sub-D Female (RS-485) | 9-pin Sub-D Female (RS-485) — Direct Replacement |
| Connector Type (PLC Side) | 9-pin Sub-D Male (MPI/PROFIBUS) | 9-pin Sub-D Male (MPI/PROFIBUS) — Direct Replacement |
| Supported Protocols | MPI, PPI, PROFIBUS DP (RS-485) | MPI, PPI, PROFIBUS DP (RS-485) — Full Compatibility |
| Max Baud Rate | Up to 12 Mbit/s (MPI) | Up to 12 Mbit/s (MPI) — Unchanged |
| Compatible Controllers | S7-200, S7-300, S7-400 | S7-200, S7-300, S7-400 — Verified Compatible |
| Compatible HMI / OP Panels | OP7, OP17, TP170, MP270, TP177, MP377 | OP7, OP17, TP170, MP270, TP177, MP377 — Direct Fit |
| Physical Standard | EN 50170 PROFIBUS | EN 50170 PROFIBUS — Compliant |
| Installation Requirement | No additional hardware | No additional hardware — Plug-and-Play |
| Program Modification Required | None | None — Zero Reprogramming |
| Warranty | Varies / Often expired on legacy units | 12-Month Warranty from TOPNLMS |
A complete SIMATIC NET migration or control cabinet retrofit rarely involves a single component. When replacing the 6XV1440-2KH32 as part of a broader system upgrade, the following components are commonly required in the same project scope:
The SIMATIC S7-300 CPU 315-2 DP is the most frequent controller pairing for this cable, providing the onboard MPI and PROFIBUS DP ports that the 6XV1440-2KH32 connects to. Sites upgrading from a CPU 312 or CPU 313 will find that the 315-2 DP retains the same S7-300 rack form factor, allowing the existing SIMATIC S7-300 PS 307 power supply module and SM 321 digital input modules to remain in place. The IM 360 / IM 361 expansion rack interface modules used in multi-rack S7-300 configurations continue to communicate over the internal bus without modification.
On the HMI side, facilities transitioning from OP7 or OP17 text panels to a SIMATIC TP177B touch panel will use the 6XV1440-2KH32 to establish the MPI link during the initial commissioning phase before migrating to Ethernet-based communication via a CP 343-1 Ethernet communication processor. The CP 343-1 is frequently added to the S7-300 rack during modernization projects to enable PROFINET connectivity alongside the legacy MPI segment, allowing the new HMI and the old programming interface to coexist during the transition period.
For PROFIBUS DP field device segments, the ET 200M IM 153-2 interface module remains the standard remote I/O head station in S7-300 systems. The 6XV1440-2KH32 is used as the local patch cable between the IM 153-2 and the nearest PROFIBUS DP bus connector, particularly in control cabinets where the DP trunk cable terminates at a PROFIBUS DP bus connector 6ES7972-0BB52-0XA0 with integrated termination resistor. Drives connected to the same PROFIBUS segment—such as the SINAMICS G120 CU240E-2 DP control unit—are addressed and parameterized through the same physical layer that the 6XV1440-2KH32 supports.
Programming and diagnostic workflows depend on the PC Adapter USB A2 (6ES7972-0CB20-0XA0) as the modern replacement for older MPI/PROFIBUS PC adapters. The 6XV1440-2KH32 complements this adapter by providing the fixed-length segment cable between the adapter’s Sub-D port and the CPU’s MPI interface, a combination that remains the standard offline programming setup for S7-300 systems not yet connected to a PROFINET infrastructure.
Q: Do I need to modify my STEP 7 or TIA Portal project when replacing the cable?
No. The 6XV1440-2KH32 is a passive cable with no firmware or configurable parameters. Replacing a failed or end-of-life cable requires no changes to the PLC program, hardware configuration, or HMI project. Simply disconnect the old cable, connect the 6XV1440-2KH32, and resume communication.
Q: Is the cable compatible with both MPI and PROFIBUS DP on the same physical port?
Yes. The S7-300 CPU’s integrated port supports both MPI and PROFIBUS DP protocols over the same RS-485 physical layer. The 6XV1440-2KH32 is electrically compatible with both protocol modes. The active protocol is determined by the CPU configuration in STEP 7 or TIA Portal, not by the cable.
Q: Can this cable be used with S7-200 CPUs running PPI protocol?
Yes. The PPI protocol used by SIMATIC S7-200 CPUs (CPU 224, CPU 226) operates over the same RS-485 physical layer. The 6XV1440-2KH32 supports PPI communication at baud rates up to 187.5 kbit/s, which covers all standard S7-200 PPI configurations.
Q: Will the cable fit in a standard 19-inch control cabinet without cable management issues?
The 3.2-meter length is designed for panel-to-panel or panel-to-rack connections within a single control cabinet row or between adjacent cabinets. The cable’s outer diameter and bend radius are consistent with standard PROFIBUS cable routing practices. No special cable duct modifications are required.
Q: What if my existing PROFIBUS segment uses bus connectors with integrated termination?
The 6XV1440-2KH32 terminates at standard 9-pin Sub-D connectors. If your segment uses PROFIBUS bus connectors with integrated termination resistors (such as the 6ES7972-0BB52-0XA0), the cable connects to the outgoing port of the bus connector in the normal manner. Termination settings on the bus connector are not affected by the cable replacement.
Q: How do I verify communication is restored after installation?
After connecting the 6XV1440-2KH32, open STEP 7 (Accessible Nodes) or TIA Portal (Online & Diagnostics) and scan the MPI/PROFIBUS network. The connected CPU or HMI should appear within 10–30 seconds. If the device does not appear, verify that the baud rate setting in the programming software matches the CPU’s configured MPI baud rate (default: 187.5 kbit/s for MPI).
Every 6XV1440-2KH32 unit supplied by TOPNLMS is covered by a 12-month warranty from the date of shipment. This warranty covers manufacturing defects, connector failure, and cable continuity faults under normal industrial operating conditions. Units that fail within the warranty period are eligible for free replacement or full refund, subject to return inspection.
Pre-shipment testing: Each cable undergoes a full continuity test across all signal and shield conductors, a connector retention force check, and a visual inspection for jacket integrity before dispatch. Test records are retained for traceability.
Shipping and lead time: Stock is maintained in Xiamen, China. Standard dispatch is within 1–2 business days of order confirmation. International shipment via DHL Express or FedEx International Priority typically delivers within 3–7 business days depending on destination. Full tracking information is provided at the time of dispatch.
After-sales support: Technical queries regarding compatibility, installation, or commissioning can be directed to our engineering team at [email protected] or by phone at +86 18359293191. Response time is within 1 business day.
Procurement assurance: TOPNLMS maintains buffer stock of high-demand SIMATIC NET cables and communication components to support urgent replacement orders. Volume pricing is available for MRO procurement teams and system integrators managing multi-site maintenance contracts.
Click Quote This Model and the Part Number field will auto-fill with 6XV1440-2KH32.