Language English USD Currency
Call WhatsApp RFQ
Yokogawa Industrial Automation Part

YOKOGAWA F3PU26-ON Original Industrial Spare FA-M3 Compatible

Request availability, condition, lead time and export shipping details for F3PU26-ON.

Yokogawa

F3PU26-ON

Send this exact part number, quantity and destination country. TOPNLMS will confirm availability, condition and export lead time before quotation.

Part NumberF3PU26-ON
CategoryPower Supply
ConditionAvailability Check
Lead TimeRFQ Confirmation
SeriesFA-M3
ShippingExport packing available
Model checked before quotation Condition and packing confirmed Fast RFQ response by sales engineer

Product Overview

YOKOGAWA F3PU26-ON FA-M3 PLC Power Supply Module: System Stability & Industrial Spare Value

The YOKOGAWA F3PU26-ON is an original power supply module designed for the FA-M3 Series programmable logic controller platform — one of YOKOGAWA’s most widely deployed process and factory automation architectures. In industrial environments where continuous uptime is non-negotiable, the power supply module is the backbone of every control cabinet. A degraded or failed power supply cascades into I/O faults, communication dropouts, and unplanned shutdowns. Maintaining a verified, original F3PU26-ON in your spare parts inventory is one of the most cost-effective decisions a maintenance engineer can make.

Whether you are managing a petrochemical DCS installation, a water treatment SCADA system, or a discrete manufacturing line built on FA-M3 hardware, the F3PU26-ON delivers the stable DC bus voltage that every downstream module depends on. Its original YOKOGAWA design ensures full compatibility with FA-M3 base units, CPU modules, and I/O racks without requiring firmware reconfiguration or hardware adaptation.

Critical Technical Specs

Parameter Specification
Model / SKU F3PU26-ON
Brand YOKOGAWA Electric Corporation
Series FA-M3 (FACTORY ACE)
Module Type PLC Power Supply Module
Input Voltage 100–240 VAC, 50/60 Hz (wide-range AC input)
Output Voltage 5 VDC (internal bus), 24 VDC auxiliary (model-dependent)
Output Current Capacity Up to 6 A on 5 VDC bus (refer to FA-M3 system manual for rack load calculation)
Compatibility FA-M3 base units, F3SP-series CPU modules, F3BU-series racks, F3NC/F3LC communication modules
Mounting Dedicated power supply slot on FA-M3 base unit (left-most slot)
Operating Temperature 0°C to 55°C
Storage Temperature -20°C to 70°C
Humidity 10% to 90% RH (non-condensing)
Protection Class IP20 (panel-mount installation)
Country of Origin Japan
Condition Original / Genuine — New or Tested Surplus
Warranty 12 Months from date of shipment
Pre-shipment Testing Functional power-on test performed before dispatch

Preventive Maintenance Strategy

Power supply modules in FA-M3 systems are often overlooked during scheduled maintenance because they operate silently in the background — until they don’t. A proactive maintenance strategy treats the F3PU26-ON not as a reactive replacement but as a scheduled lifecycle component. Industry best practice recommends inspecting and considering replacement of power supply modules every 5–7 years in continuous-duty environments, or immediately upon observing symptoms such as intermittent CPU resets, unexplained I/O errors, or bus voltage alarms logged in the FA-M3 system diagnostics.

When performing a planned shutdown inspection of an FA-M3 control cabinet, the power supply module should never be evaluated in isolation. The F3PU26-ON feeds the entire rack, meaning that a thorough inspection should simultaneously cover the F3SP28-4S or F3SP38-6S CPU module for firmware integrity and battery status, as well as the F3BU04-0N or F3BU16-0N base unit for backplane connector wear. Technicians should also verify the condition of F3DA04-1N analog output modules and F3AD08-6R analog input modules, since power transients from a degrading supply can corrupt calibration registers in analog I/O channels.

Communication continuity is equally critical. The F3LC11-1F Ethernet communication module and F3NC32-0N PROFIBUS-DP module are sensitive to bus voltage fluctuations; a marginal power supply is a common root cause of intermittent network timeouts that are frequently misdiagnosed as software or cabling issues. During the same maintenance window, inspect the F3YD32-0N digital output module relay contacts for wear, and check the F3XD32-3N digital input module for contamination on terminal blocks.

For facilities managing aging FA-M3 installations, it is also advisable to stock a spare F3PU16-0N power supply module (the lower-capacity variant) alongside the F3PU26-ON, ensuring coverage across mixed-rack configurations. Terminal block assemblies, DIN rail mounting hardware, and 24 VDC auxiliary fuse modules within the same cabinet should be inspected and replaced on the same cycle to avoid a secondary failure immediately after a power supply swap.

Strategic Replacement Solutions

The F3PU26-ON is a direct original replacement for aging power supply modules in FA-M3 systems that have been in service since the early 2000s. Many facilities running legacy YOKOGAWA FA-M3 installations face the challenge of sourcing original modules as the product approaches end-of-active-production status. Using a non-original or incompatible power supply risks bus voltage tolerance mismatches that can cause erratic CPU behavior, I/O module faults, and in worst cases, permanent damage to downstream modules.

By sourcing an original F3PU26-ON, maintenance teams avoid the engineering overhead of system redesign, retain full compatibility with existing FA-M3 programming (ladder logic, function block diagrams, and structured text programs remain untouched), and extend the operational life of the control system by 5–10 years without capital expenditure on a full PLC migration. This is particularly valuable in process industries where a control system migration requires extensive validation, regulatory re-approval, and production downtime that can cost multiples of the spare part value.

All units supplied by TOPNLMS undergo functional power-on verification prior to shipment. Each F3PU26-ON is packaged in anti-static protective material with inspection documentation. Standard lead time is 3–7 business days for in-stock units, with express shipping available for emergency maintenance situations. A 12-month warranty covers all units against manufacturing defects and functional failure under normal operating conditions.

Support FAQ

Q1: Is this F3PU26-ON a genuine YOKOGAWA original module or a compatible substitute?
All F3PU26-ON units listed by TOPNLMS are original YOKOGAWA-manufactured modules — either new old stock or tested surplus from decommissioned FA-M3 systems. We do not supply third-party compatible substitutes for this model. Each unit is verified against YOKOGAWA’s original part markings and label specifications before listing.

Q2: How do I confirm the F3PU26-ON is compatible with my specific FA-M3 rack configuration?
The F3PU26-ON is compatible with all standard FA-M3 base units (F3BU04-0N, F3BU08-0N, F3BU12-0N, F3BU16-0N) and is installed in the dedicated power supply slot. Compatibility is determined by the base unit model, not by the CPU or I/O modules installed. If you are uncertain, provide your base unit model number and we will confirm compatibility before shipment.

Q3: What pre-shipment testing is performed, and what does the 12-month warranty cover?
Every F3PU26-ON undergoes a functional power-on test to verify output voltage regulation and protection circuit operation before dispatch. The 12-month warranty covers functional failure under normal operating conditions, including output voltage out-of-specification and protection circuit malfunction. Physical damage caused by incorrect installation, overvoltage events, or environmental contamination is excluded. Warranty claims are processed within 5 business days of receipt of the returned unit.

Q4: What is the recommended spare parts inventory strategy for FA-M3 power supply modules?
For facilities with 1–3 FA-M3 racks, maintaining one F3PU26-ON spare per rack type is standard practice. For larger installations (4+ racks) or critical process applications, a ratio of one spare per two operational units is recommended. Given the extended lead times that can occur for legacy YOKOGAWA modules, procuring spares during planned maintenance shutdowns — rather than waiting for a failure event — significantly reduces the risk of extended unplanned downtime.

Quick Inquiry

Click Quote This Model and the Part Number field will auto-fill with F3PU26-ON.