Yaskawa CSRA-CV10A02A/YRC1000 DC Bus Converter Module
CSRA-CV10A02A/YRC1000Yaskawa CSRA-CV10A02A/YRC1000 ruggedized DC bus converter module for YRC1000 robot controllers. In stock, tested, 12-month warranty. Ships in 1–3 days.
Request availability, condition, lead time and export shipping details for CE B 400V470UF.
Send this exact part number, quantity and destination country. TOPNLMS will confirm availability, condition and export lead time before quotation.
The YASKAWA CE-B 400V470UF is a DC bus capacitor module designed for use within YASKAWA’s CE-B Series AC drives — a platform widely deployed across manufacturing, HVAC, pump, fan, and conveyor applications throughout Asia and globally. As CE-B Series drives age and OEM support diminishes, the DC bus capacitor is statistically one of the first components to degrade, causing DC bus undervoltage faults, erratic drive behavior, or complete drive failure. TOPNLMS stocks, tests, and ships the CE-B 400V470UF as a direct replacement to restore drive performance without requiring a full drive changeout.
Whether your maintenance team is responding to an unplanned drive fault or executing a scheduled preventive replacement during a planned shutdown, this capacitor module is available from our Xiamen facility with standard lead times of 1–3 business days for in-stock units. Expedited shipping is available for urgent plant situations.
| Parameter | Legacy / Degraded Unit | CE-B 400V470UF (This Module) |
|---|---|---|
| Platform | YASKAWA CE-B Series AC Drive | YASKAWA CE-B Series — direct fit |
| Rated Voltage | 400V DC bus | 400V — identical rating |
| Capacitance | 470µF | 470µF — exact match |
| Form Factor / Mounting | OEM capacitor bank position in CE-B drive chassis | Direct drop-in — same mounting footprint and terminal positions |
| Terminal / Wiring | Existing DC bus bar connections | No rewiring required — reconnect existing bus bars |
| Communication Impact | N/A (passive component) | No communication reconfiguration required after replacement |
| Drive Parameter Retention | Parameters stored in drive keypad/memory | Capacitor swap does not affect stored drive parameters |
| Replacement Recommendation | Degraded, bulging, or failed DC bus capacitor | Direct replacement; tested before shipment |
| Warranty | OEM warranty expired | 12-Month TOPNLMS Warranty |
DC bus capacitor failure in a YASKAWA CE-B Series drive rarely occurs in complete isolation. In aging drive systems, the capacitor bank degradation is often accompanied by wear in adjacent power electronics. Engineers performing a capacitor replacement frequently inspect and address the YASKAWA CE-B Series gate driver board and IGBT module at the same time, as thermal cycling and electrolytic aging affect these components on similar timescales. If the drive’s cooling system has been compromised, the CE-B Series cooling fan assembly is a standard co-replacement item to prevent recurrence of thermal-related faults.
For facilities managing a fleet of YASKAWA drives across multiple production lines, it is common to maintain a buffer stock of the YASKAWA CIMR-G5 Series and CIMR-F7 Series drive components alongside CE-B spares, as these platforms share similar DC bus architectures and maintenance intervals. When the CE-B drive itself is beyond economic repair, the YASKAWA A1000 Series or YASKAWA V1000 Series inverter represents the current-generation migration path, offering backward-compatible control terminal wiring in many configurations and supporting the same Modbus RTU and MEMOBUS communication protocols used in legacy CE-B installations.
During a drive upgrade from CE-B to A1000 or V1000, the existing YASKAWA SI-P3/V option card for PROFIBUS-DP or the SI-EN3/V Ethernet/IP option card can be evaluated for reuse or direct replacement, preserving the plant’s existing fieldbus architecture without requiring PLC-side reconfiguration. Field wiring to the control terminal block — including analog speed reference signals, digital run/stop commands, and fault relay outputs — typically maps directly to the new drive’s terminal layout with minimal modification.
Where the CE-B drive interfaces with a YASKAWA MP2300 Machine Controller or a third-party PLC via pulse train or analog reference, the signal interface remains unchanged during a capacitor-level repair. For full drive replacements, a signal isolator or analog signal conditioner may be introduced to bridge any reference voltage differences between the legacy control system and the new drive’s input specifications.
TOPNLMS can advise on compatible spare parts, option cards, and migration components based on your specific CE-B drive model number and application requirements. Contact our technical team with your drive nameplate data for a tailored recommendation.
Q: Can I replace the DC bus capacitor without removing the entire CE-B drive from the control cabinet?
A: In most CE-B Series installations, the drive must be de-energized and the DC bus fully discharged before capacitor access. Depending on cabinet layout, partial removal of the drive chassis may be required. Always follow YASKAWA’s discharge procedure and verify DC bus voltage is below 25V before touching internal components.
Q: Will replacing the capacitor reset my drive parameters?
A: No. Drive parameters are stored in the drive’s non-volatile memory (EEPROM), not in the capacitor. A capacitor replacement does not affect stored parameter values. However, we recommend backing up parameters via the YASKAWA DriveWizard software or the drive’s copy keypad before any internal maintenance.
Q: How do I confirm the capacitor is the root cause of my DC bus fault?
A: Common indicators of capacitor degradation include DC bus undervoltage faults (UV1/UV2), increased drive warm-up time, visible capacitor bulging or electrolyte leakage, and elevated ripple current measured on the DC bus. A capacitance meter test on the removed capacitor bank will confirm degradation below rated capacitance.
Q: Is this capacitor compatible with 3-phase 400V input configurations only?
A: The CE-B 400V470UF is rated for 400V DC bus applications, corresponding to 3-phase 380–415V AC input drives in the CE-B Series. It is not interchangeable with 200V class CE-B variants, which use different voltage-rated capacitor banks.
Q: What is the expected service life after replacement?
A: Under normal operating conditions (ambient temperature ≤40°C, rated load), electrolytic DC bus capacitors in industrial drives typically achieve 5–10 years of service life. Operating at elevated temperatures significantly reduces this. TOPNLMS recommends implementing a preventive replacement schedule based on operating hours and ambient conditions.
Q: Can TOPNLMS supply the full CE-B drive if the capacitor replacement is not sufficient?
A: Yes. If post-replacement testing confirms additional drive damage, TOPNLMS can source complete CE-B Series drives or recommend a current-generation YASKAWA replacement. Contact our team with your drive model and power rating for availability.
Every YASKAWA CE-B 400V470UF capacitor module shipped by TOPNLMS is covered by a 12-Month Warranty from the date of delivery. Prior to shipment, each unit undergoes capacitance verification, insulation resistance testing, and visual inspection for physical integrity. Units that do not meet our outgoing quality standards are not shipped.
In the event of a warranty claim, TOPNLMS provides a replacement unit or full refund based on confirmed fault. Our after-sales response target is within 24 hours of claim submission. We support customers through the return and replacement process with streamlined documentation to minimize administrative burden during urgent maintenance situations.
For time-critical plant shutdowns or emergency replacement scenarios, expedited shipping options are available to most global destinations. Standard lead time from confirmed order to dispatch is 1–3 business days for in-stock units. Stock availability is updated regularly — we recommend confirming availability before scheduling your maintenance window.
Click Quote This Model and the Part Number field will auto-fill with CE B 400V470UF.