VIPA 240-1CA00 Original Industrial Spare CP 240 Compatible
240-1CA00VIPA 240-1CA00 CP 240 Serial Communication Processor Module. Original industrial spare, 12-month warranty, fast shipping. Compatible replacement for legacy VIPA PLC systems.
Request availability, condition, lead time and export shipping details for SSN-BG89A.
Send this exact part number, quantity and destination country. TOPNLMS will confirm availability, condition and export lead time before quotation.
The VIPA SSN-BG89A is an original Ethernet communication module engineered for the VIPA System SLIO modular I/O platform — one of the most widely deployed compact automation architectures in European and global industrial facilities. In production environments where network integrity directly determines uptime, the SSN-BG89A serves as the backbone of real-time data exchange between SLIO I/O stations and higher-level controllers, SCADA systems, and industrial Ethernet networks. Sourced as a genuine original spare, this module is the correct choice for maintenance teams that cannot afford compatibility uncertainty during a critical replacement event.
Whether your facility operates continuous process lines, discrete manufacturing cells, or hybrid automation architectures, the SSN-BG89A provides the deterministic Ethernet communication performance that SLIO-based control cabinets depend on. Its compact SLIO form factor allows direct hot-swap installation into existing backplane assemblies without mechanical modification, minimizing mean time to repair (MTTR) and reducing the risk of extended unplanned downtime.
| Parameter | Specification |
|---|---|
| Part Number / SKU | SSN-BG89A |
| Brand / Manufacturer | VIPA GmbH (Yaskawa Europe) |
| Series | System SLIO |
| Module Type | Ethernet Communication Module (Network Card) |
| Communication Interface | Industrial Ethernet (100 Mbit/s) |
| Protocol Support | PROFINET IO, Modbus TCP (series-dependent) |
| Form Factor | SLIO modular backplane-mount |
| Supply Voltage | DC 24 V (via SLIO backplane bus) |
| Operating Temperature | 0 °C … +60 °C |
| Storage Temperature | -25 °C … +70 °C |
| Protection Class | IP20 |
| Country of Origin | Germany (DE) |
| Compatibility | VIPA System SLIO modular I/O stations; compatible with VIPA CPU 01x, 02x, 03x series controllers and third-party PROFINET masters |
| Installation | Direct SLIO backplane insertion; no tools required for module swap |
| Condition | Original new / surplus original |
| Warranty | 12 Months — tested before shipment |
Experienced maintenance engineers know that a communication module failure rarely occurs in isolation. When the SSN-BG89A is flagged for replacement during a scheduled shutdown or emergency callout, the surrounding SLIO station components should be inspected simultaneously to prevent a second unplanned outage within the same maintenance cycle.
Begin with the SLIO power module (VIPA 007-1AB10 or equivalent) that feeds the backplane bus. A degraded power supply is one of the most common root causes of intermittent Ethernet communication faults that are incorrectly attributed to the network card itself. While the cabinet is open, verify the SLIO bus coupler and its terminal connections — loose or corroded bus connectors can introduce cyclic communication errors that mimic module failure.
Next, audit the SLIO digital input modules (e.g., SSN-1BD00 series) and digital output modules installed in the same rack. These modules share the backplane data bus with the SSN-BG89A; a failing I/O module can generate bus load anomalies that degrade Ethernet throughput. If the facility uses analog process signals, inspect the SLIO analog input/output modules for drift or calibration deviation — a common finding during annual preventive maintenance rounds.
For cabinets that include VIPA CPU modules (e.g., VIPA 315-2AG23 or 317-4NE12) communicating over the same Ethernet segment, verify firmware compatibility between the CPU and the SSN-BG89A. Mismatched firmware versions are a documented source of PROFINET IO communication instability after module replacement. Keep a spare VIPA memory card (VSD or VSC series) in your stockroom to enable rapid CPU program restore if a controller requires re-initialization during the repair sequence.
The Ethernet patch cables and industrial managed switches connecting the SLIO station to the plant network should also be tested during the same maintenance window. Industrial-grade Cat6 shielded cables and DIN-rail mounted switches (such as those from the SCALANCE X or equivalent series) are frequently overlooked until a second communication fault surfaces weeks after the module swap. Additionally, inspect terminal blocks and signal isolators on the I/O side — degraded terminal connections increase ground loop risk and can introduce noise that affects communication reliability.
Finally, if the control cabinet houses a VIPA TP or CP HMI panel communicating via the same Ethernet network, verify its IP configuration and network timeout parameters after the SSN-BG89A replacement. HMI communication parameters sometimes require re-validation following a network card change, particularly in older SLIO installations where static IP addressing is used.
The SSN-BG89A addresses one of the most pressing challenges in industrial maintenance: replacing a discontinued or end-of-life communication module without redesigning the control architecture. VIPA System SLIO installations from the mid-2000s through the 2010s remain operational in thousands of facilities worldwide, and sourcing original spare modules has become increasingly difficult through standard distribution channels.
By stocking the SSN-BG89A as an original spare, maintenance teams eliminate the need for costly engineering work to migrate to a newer communication platform. The module installs directly into the existing SLIO backplane, retains the original PROFINET IO device name and IP address configuration, and requires no changes to the PLC program or SCADA tag database. This preserves the validated control logic that production teams depend on and avoids the re-commissioning risk associated with platform migration.
For facilities managing aging SLIO systems, a proactive spare-holding strategy — maintaining one or two SSN-BG89A units in the on-site stockroom — reduces the expected downtime cost of a communication module failure from days (sourcing lead time) to under one hour (physical swap and network re-verification). Given the production value at risk during an unplanned shutdown in process or discrete manufacturing, the inventory carrying cost of a spare module is negligible by comparison.
All units supplied by TOPNLMS are tested prior to shipment, documented with inspection records, and covered by a 12-month warranty. Worldwide shipping is available with standard and expedited options to support urgent maintenance requirements.
Q1: Is the SSN-BG89A compatible with all VIPA System SLIO configurations?
The SSN-BG89A is designed for the VIPA System SLIO modular backplane platform and is compatible with standard SLIO rack assemblies. Compatibility with specific CPU masters (VIPA or third-party PROFINET IO controllers) should be verified against the installed firmware version and GSD/GSDML device description file. Contact us with your existing system configuration for pre-sale compatibility confirmation.
Q2: What testing is performed before shipment?
Each SSN-BG89A unit undergoes functional power-on testing and communication interface verification prior to dispatch. Units are inspected for physical integrity, connector condition, and firmware version. A test report is available upon request. All units are shipped in anti-static packaging with protective end caps.
Q3: How should I manage spare parts inventory for a SLIO-based system?
For SLIO installations with 10 or more I/O stations, we recommend maintaining at minimum one spare SSN-BG89A Ethernet module, one spare power module, and one spare unit of each I/O module type in active use. For critical production lines, a complete spare rack assembly is the industry best practice. TOPNLMS can assist with spare parts planning and bulk procurement to optimize your inventory investment.
Q4: What is covered under the 12-month warranty?
The 12-month warranty covers manufacturing defects and functional failure under normal operating conditions as specified in the VIPA SLIO technical documentation. Warranty claims are processed with priority support. In the event of a confirmed defective unit, replacement or refund options are available. The warranty period begins from the date of shipment. Physical damage caused by incorrect installation, overvoltage, or environmental conditions outside the rated specification is excluded.
Click Quote This Model and the Part Number field will auto-fill with SSN-BG89A.