Siemens A5E33032455 Replacement/Upgrade Solution for SIMATIC S7
A5E33032455Buy Siemens A5E33032455 – direct replacement & upgrade for SIMATIC S7-300/S7-400. PROFIBUS/PROFINET compatible, drop-in fit, 12-month warranty. Ships globally.
Request availability, condition, lead time and export shipping details for QLCCM24AAN.
Send this exact part number, quantity and destination country. TOPNLMS will confirm availability, condition and export lead time before quotation.
The Siemens QLCCM24AAN (Part No. 16418-41’1) is a BACnet Communicating Control Module (CCM) designed for 24 V AC/DC operation within the Siemens APOGEE and Desigo building automation platform. As legacy APOGEE field panels and Desigo PX controllers reach end-of-life or become increasingly difficult to source, facilities engineers and system integrators face mounting pressure to maintain uptime while planning a structured migration path. This product page is designed to support that decision — providing compatibility data, upgrade guidance, and procurement assurance for the QLCCM24AAN and its role in a broader system modernization project.
Whether you are replacing a failed unit in an existing APOGEE MBC (Modular Building Controller) installation, consolidating a multi-panel Desigo network, or preparing a phased retrofit of an older P1 or P2 field panel system, the QLCCM24AAN offers a direct, wiring-compatible replacement path that minimizes engineering rework and commissioning time on site.
| Parameter | Legacy / Replaced Model | QLCCM24AAN 16418-41’1 |
|---|---|---|
| Platform | APOGEE P1 / P2 Field Panel, MBC 100/200 | APOGEE / Desigo PX MBC, FLN Panel |
| Communication Protocol | P1 FLN, P2 FLN (proprietary Siemens) | BACnet MS/TP, BACnet IP (via upstream router) |
| Supply Voltage | 24 V AC (transformer-fed) | 24 V AC/DC (universal input) |
| Physical Form Factor | DIN-rail / panel-mount module | DIN-rail / panel-mount, same footprint |
| Wiring Terminals | Screw-terminal, 2.5 mm² | Screw-terminal, 2.5 mm² — direct re-use |
| I/O Expansion | Via legacy I/O modules (TEC, TXM) | Compatible with Desigo TXM1.8U, TXM1.6R, TXM1.8D I/O modules |
| Programming Tool | APOGEE Terminal (AT), P1 Workstation | Desigo Insight / TALON / BACnet commissioning tool |
| Network Addressing | FLN node address (hardware DIP switch) | BACnet Device Instance (software-configurable) |
| Replacement Recommendation | Direct drop-in for same-generation APOGEE CCM variants; program re-download required for Desigo migration | |
| Warranty | OEM warranty (expired on legacy units) | 12-Month Warranty — covered from date of shipment |
A successful migration from a legacy APOGEE or Desigo system to a modernized BACnet architecture rarely involves a single module swap. In practice, the QLCCM24AAN is deployed alongside a coordinated set of components that together ensure wiring continuity, protocol compatibility, and physical fit within the existing control cabinet.
On the I/O side, the Siemens TXM1.8U universal input module and TXM1.6R relay output module are the most common companions to the QLCCM24AAN in Desigo PX panel builds. These modules connect via the Desigo local bus and allow engineers to reuse existing field wiring for analog inputs (0–10 V, 4–20 mA, NTC/Pt1000 sensors) and digital outputs without re-terminating at the field device level. Where the legacy system used TEC (Terminal Equipment Controller) modules for zone-level control, the TXM series provides a functionally equivalent replacement with improved diagnostics.
For BACnet network integration, the Siemens PXG3.W100 BACnet/IP to MS/TP router is frequently required when connecting the QLCCM24AAN to a higher-level Desigo CC or third-party BMS over Ethernet. This router bridges the MS/TP trunk — where the CCM resides — to the IP backbone, enabling seamless integration with SCADA systems, energy management platforms, and cloud-based monitoring tools without replacing the field-level wiring infrastructure.
Power supply continuity is another critical consideration. The Siemens SITOP PSU100S 24 V DC power supply is widely used in Desigo panel builds to provide stable, regulated 24 V DC to the CCM and associated I/O modules. When replacing a legacy transformer-fed 24 V AC panel, engineers should verify whether the QLCCM24AAN’s universal AC/DC input allows direct reuse of the existing transformer, or whether a regulated DC supply is preferred for improved noise immunity in electrically noisy industrial environments.
Programming and commissioning the QLCCM24AAN after a migration typically requires a Siemens programming cable (USB-to-RS485 adapter compatible with Desigo PX tools) and access to the Desigo Insight or TALON commissioning software. Where the legacy system was programmed using the APOGEE Terminal (AT) software, the application logic must be re-entered or converted — the QLCCM24AAN does not support direct import of P1/P2 FLN application files. This is a one-time engineering effort that is offset by the long-term benefits of operating on a supported, standards-based BACnet platform.
In larger retrofit projects involving multiple field panels, the Siemens PXC3.E72 Desigo PX Compact controller is often deployed in parallel with the QLCCM24AAN to handle zones requiring higher I/O density or advanced control sequences. The two devices can coexist on the same BACnet MS/TP trunk, allowing a phased migration where individual panels are upgraded one at a time without disrupting the rest of the building automation network. Similarly, the Siemens RXB21.1/FC room controller and QMX3.P37 room operator unit are commonly integrated into the same Desigo network during HVAC zone-level upgrades, providing occupant-facing controls that communicate natively over BACnet.
For installations where signal isolation is required between the field wiring and the control module — particularly in older buildings with long cable runs or mixed-voltage environments — DIN-rail signal isolators (such as the Phoenix Contact MINI MCR series or equivalent) are recommended between the field sensors and the TXM input modules. This protects the QLCCM24AAN from ground loops and transient voltages that are common in legacy panel retrofits.
Q: Can I reuse existing field wiring when replacing a legacy APOGEE CCM with the QLCCM24AAN?
A: In most cases, yes. The QLCCM24AAN uses the same screw-terminal format and 24 V supply as the legacy APOGEE CCM variants. Field wiring for analog inputs, digital outputs, and power can typically be re-terminated directly without re-pulling cables. Verify terminal assignments against the QLCCM24AAN wiring diagram before energizing.
Q: Is the QLCCM24AAN compatible with the existing BACnet MS/TP trunk in my building?
A: Yes. The QLCCM24AAN communicates natively over BACnet MS/TP at standard baud rates (9600, 19200, 38400, 76800 bps). It can be added to an existing MS/TP trunk alongside other BACnet devices without protocol conversion, provided the trunk is properly terminated and the device instance address is unique.
Q: Do I need to reprogram the QLCCM24AAN after installation?
A: Yes, a program download is required. The QLCCM24AAN does not retain application logic from a previous unit. Use Desigo Insight or TALON to download the application, configure I/O assignments, and set BACnet device parameters. If replacing a failed unit of the same type, the existing application file can be re-downloaded with minimal modification.
Q: Will the QLCCM24AAN fit in the existing control cabinet?
A: The QLCCM24AAN uses a standard DIN-rail mounting format consistent with the APOGEE and Desigo PX panel family. In most cases it fits directly into the existing cabinet space. Verify DIN-rail depth and clearance for the terminal block and communication cable routing before installation.
Q: What happens to my P1/P2 FLN devices when I migrate to the QLCCM24AAN?
A: Legacy P1/P2 FLN field devices (TEC controllers, VAV controllers, etc.) are not directly compatible with the BACnet MS/TP network of the QLCCM24AAN. A phased migration approach is recommended: retain legacy FLN devices on their existing trunks where possible, and replace them with BACnet-native equivalents (such as Desigo TRA or RXB series room controllers) as part of a structured upgrade plan.
Q: Can the QLCCM24AAN communicate with a third-party BMS over BACnet/IP?
A: The QLCCM24AAN operates on BACnet MS/TP at the field level. Integration with a BACnet/IP-based BMS requires a BACnet MS/TP to IP router (such as the Siemens PXG3.W100) installed on the same trunk. Once routed, the QLCCM24AAN’s objects are fully accessible to any BACnet/IP client.
Every QLCCM24AAN 16418-41’1 unit shipped by TOPNLMS is covered by a 12-Month Warranty from the date of shipment. Prior to dispatch, each unit undergoes functional verification including power-on testing, communication port check, and visual inspection for physical damage. Units that do not pass inspection are not shipped.
In the event of a warranty claim, TOPNLMS provides replacement support with a target response time of 1–2 business days. Defective units should be returned with the original packaging and a description of the fault. Replacement units are dispatched from our Xiamen warehouse upon receipt and verification of the returned item.
Our procurement assurance commitment includes accurate part number verification before shipment, original manufacturer labeling and traceability documentation where available, and transparent communication on lead times and stock availability. For urgent replacement requirements — particularly in situations involving system downtime — expedited shipping options are available upon request.
For stock inquiries, technical compatibility questions, or bulk order pricing, contact our team directly:
📧 [email protected] | 📞 +86 18359293191
Click Quote This Model and the Part Number field will auto-fill with QLCCM24AAN.