Language English USD Currency
Call WhatsApp RFQ
Siemens Industrial Automation Part

Siemens 6XV1870-3QH10 Replacement for SIMATIC NET Series

Request availability, condition, lead time and export shipping details for 6XV1870-3QH10.

Siemens

6XV1870-3QH10

Send this exact part number, quantity and destination country. TOPNLMS will confirm availability, condition and export lead time before quotation.

BrandSiemens
Part Number6XV1870-3QH10
ConditionAvailability Check
Lead TimeRFQ Confirmation
SeriesSIMATIC NET
ShippingExport packing available
Model checked before quotation Condition and packing confirmed Fast RFQ response by sales engineer

Product Overview

Siemens 6XV1870-3QH10 Replacement for SIMATIC NET Series: Smooth Transition & Legacy System Compatibility

The Siemens 6XV1870-3QH10 is a PROFINET TP Cord (Twisted Pair) with a pre-assembled length of 10 meters, designed for use within the SIMATIC NET industrial communication infrastructure. As industrial facilities continue to modernize aging control architectures, this cable assembly plays a critical role in maintaining uninterrupted PROFINET IO communication between controllers, I/O devices, and network switches during both phased upgrades and full system migrations.

Many facilities operating legacy SIMATIC S7-300 or S7-400 PLC systems are now transitioning to the SIMATIC S7-1500 platform or ET 200 distributed I/O families. During this migration, the physical network layer — including PROFINET cabling — must be carefully evaluated. The 6XV1870-3QH10 provides a direct, plug-and-play replacement for worn or discontinued pre-assembled PROFINET cords, eliminating the need for field-termination and reducing installation errors during live system retrofits.

When upgrading from older SIMATIC NET topologies that relied on Industrial Ethernet switches such as the SCALANCE X208 or SCALANCE XB008, the 6XV1870-3QH10 ensures backward-compatible RJ45 connectivity. Its Cat 5e-equivalent shielded twisted pair construction meets the PROFINET cabling specification for 100 Mbit/s Fast Ethernet, making it suitable for both star and line topologies commonly found in existing control cabinet layouts.

In retrofit projects involving CP 343-1 or CP 443-1 communication processors on S7-300/400 racks, replacing degraded or non-compliant patch cords with the 6XV1870-3QH10 is a low-risk, high-impact step. The pre-assembled RJ45 connectors are rated for industrial environments and comply with IP20 protection requirements for cabinet-internal use, ensuring reliable signal integrity without additional field assembly.

For distributed I/O expansions using ET 200SP or ET 200M stations connected via PROFINET, maintaining consistent cable quality across all segments is essential. Mixing field-terminated cables with pre-assembled cords of inconsistent impedance can introduce latency or packet loss in time-sensitive PROFINET IRT (Isochronous Real-Time) applications. The 6XV1870-3QH10 eliminates this variability, providing a factory-tested, impedance-matched solution for every node connection.

Control cabinet integrators working with SIMATIC S7-1200 or S7-1500 controllers alongside HMI panels such as the SIMATIC TP700 Comfort or KTP900 Basic will find the 6XV1870-3QH10 ideal for structured internal wiring. Its 10-meter length accommodates larger cabinet assemblies or inter-cabinet runs without requiring field splicing, preserving the shielding continuity critical for EMC compliance in high-noise industrial environments.

During system commissioning or planned maintenance windows, having pre-tested replacement cords on hand significantly reduces mean time to repair (MTTR). The 6XV1870-3QH10 is a direct drop-in replacement that requires no re-programming of the PROFINET device name or IP address assignment — the network topology remains intact, and the STEP 7 or TIA Portal project configuration does not need modification.

Facilities managing spare parts inventories for SIMATIC NET infrastructure should consider stocking the 6XV1870-3QH10 alongside related components such as the SCALANCE XB005G unmanaged switch, IE FC RJ45 Plug 180 connectors, and SIMATIC NET IE FC TP Standard Cable GP 2×2 bulk cable. This ensures a complete cabling solution is available for both planned upgrades and emergency replacements without extended lead times.

For projects involving signal isolation between PROFINET segments or integration with legacy PROFIBUS DP networks, the 6XV1870-3QH10 is typically deployed on the PROFINET side of a PN/DP coupler or IE/PB Link PN IO gateway. This architecture allows older PROFIBUS field devices — such as Siemens ET 200B or third-party valve terminals — to remain in service while the upper control layer migrates to PROFINET, protecting the existing field wiring investment.

All units are sourced from verified supply channels, individually inspected prior to dispatch, and shipped with full traceability documentation. Standard lead time is 3–7 business days from Xiamen, with express options available for urgent replacement requirements.

Compatibility Comparison Table

Parameter 6XV1870-3QH10 (This Unit) Typical Legacy / Field-Terminated Alternative
Cable Type PROFINET TP Cord, Cat 5e shielded Field-terminated IE FC TP Standard Cable
Length 10 m (pre-assembled) Variable (field cut)
Connector RJ45 (both ends), IP20 IE FC RJ45 Plug 180 / 145 (field-assembled)
Communication Protocol PROFINET IO (100 Mbit/s Fast Ethernet) PROFINET IO / Industrial Ethernet
Compatible Controllers S7-300, S7-400, S7-1200, S7-1500, ET 200SP/M/MP Same (dependent on field assembly quality)
Compatible Switches SCALANCE X/XB/XC series, any 100BASE-TX port Same
Installation Plug-and-play, no tools required Requires IE FC stripping tool and assembly
EMC Shielding Factory-tested, continuous shield Dependent on field termination quality
Replacement Risk Low — no re-configuration needed Medium — assembly errors possible
Warranty 12 Months N/A (field-assembled)

Seamless Upgrade Solutions

A complete PROFINET infrastructure upgrade typically involves more than a single cable. When replacing or extending your SIMATIC NET cabling, the following components are commonly required alongside the 6XV1870-3QH10. For cabinet-level network distribution, the SCALANCE XB008 or SCALANCE X208 unmanaged switches provide reliable 8-port Fast Ethernet switching without requiring managed configuration. Where longer runs between cabinets are needed, the SIMATIC NET IE FC TP Standard Cable GP 2×2 bulk cable paired with IE FC RJ45 Plug 180 connectors allows custom-length field assembly to complement pre-assembled cords.

In systems where the S7-300 CPU 315-2 PN/DP or CPU 317-2 PN/DP is being retained during a partial upgrade, the 6XV1870-3QH10 connects directly to the integrated PROFINET port without any adapter. For S7-400 systems using a CP 443-1 Advanced communication processor, the same cable provides the uplink to the plant network switch. When migrating to S7-1500, the CPU 1515-2 PN or CPU 1516-3 PN/DP offers dual PROFINET interfaces, and the 6XV1870-3QH10 can serve both the device-level ring and the plant backbone connection.

For distributed I/O nodes, the ET 200SP IM 155-6 PN ST interface module and ET 200MP IM 155-5 PN ST both accept standard RJ45 PROFINET connections, making the 6XV1870-3QH10 a direct fit. In HMI integration scenarios, SIMATIC TP700 Comfort or KTP1200 Basic panels connect to the PROFINET network via the same RJ45 interface, and a pre-assembled cord eliminates the risk of wiring errors during panel installation or replacement.

Retrofit Guidance FAQ

Q: Will replacing the existing PROFINET cord with the 6XV1870-3QH10 require changes to the TIA Portal or STEP 7 project?
A: No. The 6XV1870-3QH10 is a passive cable assembly. Replacing a degraded or non-compliant cord does not alter the PROFINET device name, IP address, or GSD/GSDML configuration. The network topology and controller program remain unchanged.

Q: Is this cable compatible with PROFINET IRT (Isochronous Real-Time) applications?
A: Yes. The cable meets the PROFINET cabling specification for 100 Mbit/s transmission, which is the physical layer requirement for both PROFINET RT and IRT. IRT scheduling is managed at the switch and controller level (e.g., SCALANCE X managed switches with IRT support), not at the cable level.

Q: Can this cord be used in environments with high electromagnetic interference (EMI)?
A: The 6XV1870-3QH10 uses a shielded twisted pair construction with a factory-terminated, continuous shield. For optimal EMC performance, ensure the cable shield is properly grounded at the cabinet entry point using an EMC cable gland or shield clamp rail.

Q: What is the maximum segment length for PROFINET using this cable?
A: Per PROFINET cabling specification, the maximum copper segment length between two active network nodes (switch ports or device ports) is 100 meters. The 6XV1870-3QH10 at 10 meters is well within this limit and is suitable for intra-cabinet or short inter-cabinet runs.

Q: Can this cable replace a field-terminated cord that was assembled on-site?
A: Yes. The 6XV1870-3QH10 is a direct physical replacement for any field-terminated PROFINET patch cord using RJ45 connectors. No re-programming or network reconfiguration is required. Simply disconnect the old cord and connect the new one.

Warranty Assurance

Every 6XV1870-3QH10 unit supplied by TOPNLMS is covered by a 12-month warranty from the date of shipment. Prior to dispatch, each unit undergoes visual inspection and continuity verification to confirm connector integrity and cable continuity. Units are packaged in anti-static, protective packaging to prevent transit damage.

In the event of a confirmed defect within the warranty period, TOPNLMS will arrange a replacement unit at no additional cost. Our after-sales response target is within 24 business hours of a warranty claim submission. For urgent replacement requirements — such as unplanned downtime situations — express shipping options are available to minimize production impact.

Procurement documentation including packing lists, commercial invoices, and test records is provided with every shipment to support your incoming inspection and asset management processes. All units are traceable to verified supply channels.

For volume orders, blanket purchase agreements, or consignment stock arrangements, please contact our sales team directly to discuss lead time commitments and pricing structures suited to your maintenance and MRO procurement strategy.

Quick Inquiry

Click Quote This Model and the Part Number field will auto-fill with 6XV1870-3QH10.