Siemens 6SL3120-1TE24-5AA3 Original S120 Motor Module
6SL3120-1TE24-5AA3Original Siemens 6SL3120-1TE24-5AA3 SINAMICS S120 Single Motor Module 45A Booksize. Genuine spare, tested, 12-month warranty. Fast global shipping from TOPNLMS.
Request availability, condition, lead time and export shipping details for 6SR4902-0AG00-0AM1.
Send this exact part number, quantity and destination country. TOPNLMS will confirm availability, condition and export lead time before quotation.
The Siemens 6SR4902-0AG00-0AM1 is a high-capacity 750A AC Power Cell designed for the SINAMICS GH180 medium-voltage drive platform. As aging GH180 installations approach end-of-service milestones or experience cell failures, sourcing a verified replacement unit becomes the single most critical step in minimizing unplanned downtime. TOPNLMS maintains ready stock of the 6SR4902-0AG00-0AM1 (A5E37684782) to support urgent retrofit, scheduled maintenance, and full drive modernization projects across cement, mining, oil & gas, water treatment, and heavy industrial sectors.
The SINAMICS GH180 architecture uses a cell-based, series-connected topology where each AC Power Cell independently rectifies and inverts a phase segment of the output voltage. When one cell degrades or fails, the entire drive output is compromised. A direct replacement with the 6SR4902-0AG00-0AM1 restores full rated output without requiring changes to the drive cabinet wiring, the fiber-optic communication harness, or the cell bypass contactor assembly. The cell’s input transformer tap connections, DC bus capacitor bank, and IGBT inverter bridge are factory-configured to match the original GH180 specification, ensuring that no re-parameterization of the SINAMICS GH180 CU (Control Unit) is required after swap-out.
For sites running older GH180 variants where the original cell part number has been superseded, the 6SR4902-0AG00-0AM1 serves as the current production replacement. Engineers should verify the cell slot position, rated input voltage tap, and firmware revision of the GH180 Cell Management Board before installation. In most cases, the replacement cell is plug-compatible with existing fiber-optic links to the SINAMICS GH180 Power Interface Module (PIM), and no additional hardware adapters are needed.
| Parameter | Legacy / Superseded Cell | 6SR4902-0AG00-0AM1 (Replacement) |
|---|---|---|
| Part Number | Earlier GH180 cell variants (6SR49xx series) | 6SR4902-0AG00-0AM1 / A5E37684782 |
| Drive Platform | SINAMICS GH180 | SINAMICS GH180 (direct fit) |
| Rated Cell Current | 750A (nominal) | 750A — matched specification |
| Communication Interface | Fiber-optic (GH180 proprietary) | Fiber-optic — fully compatible |
| Input Connection | Transformer secondary tap (phase-shifted) | Identical tap configuration — no rewiring |
| DC Bus / Capacitor Bank | Factory-matched to GH180 cell slot | Factory-matched — direct replacement |
| Cell Bypass Contactor | Compatible with existing bypass assembly | Compatible — no mechanical modification |
| Control Unit Re-parameterization | Required for non-OEM cells | Not required — OEM specification |
| Physical Dimensions | GH180 cell bay standard | Identical form factor — slide-in replacement |
| Warranty | — | 12-Month Warranty (TOPNLMS) |
A successful GH180 cell replacement rarely involves the power cell alone. During scheduled maintenance windows or emergency swap-outs, experienced engineers typically audit the surrounding components to prevent repeat failures and extend the operational life of the entire drive system.
The SINAMICS GH180 Cell Management Board communicates with each power cell via dedicated fiber-optic links. If the existing fiber harness shows signs of degradation — increased bit-error rates or intermittent cell fault codes — replacing the fiber-optic cables alongside the 6SR4902-0AG00-0AM1 eliminates a common source of nuisance trips after cell installation. Similarly, the SINAMICS GH180 Power Interface Module (PIM) distributes gate drive signals and monitors cell health; a PIM that has accumulated years of thermal cycling may benefit from inspection or replacement during the same outage.
On the control side, the SINAMICS GH180 Control Unit (CU) — typically a SINAMICS CU320-2 DP or CU320-2 PN — stores the drive parameterization and communicates upstream to the plant DCS or SCADA system via PROFIBUS DP or PROFINET IO. Customers migrating from legacy GH180 installations to a modernized architecture sometimes pair the cell replacement with a CU firmware upgrade or a transition to a newer SINAMICS S120 control platform, retaining the existing GH180 power section while gaining access to current diagnostic and energy-management features.
For sites where the upstream isolation transformer is also aging, the phase-shifting transformer that feeds the GH180 cell stack is a critical companion component. Verifying transformer tap voltages and insulation resistance before commissioning the new 6SR4902-0AG00-0AM1 is standard practice and prevents premature cell stress. Additionally, the SINAMICS GH180 Bypass Cabinet and associated motor protection relays should be tested for correct operation, as a faulty bypass contactor can mask cell faults and lead to misdiagnosis.
Where the GH180 drives a high-inertia load such as a ball mill, kiln, or large pump, the SINAMICS GH180 Braking Module and associated DC link components should be inspected concurrently. Customers who also operate SINAMICS GM150 or SINAMICS SM150 medium-voltage drives on the same site will find that the cell replacement workflow and spare-parts logistics are closely aligned, allowing consolidated procurement and reduced engineering overhead.
For the low-voltage control cabinet associated with the GH180 installation, components such as the SIMATIC S7-300 or SIMATIC S7-1500 PLC handling sequencing logic, the SIMATIC HMI TP1200 Comfort operator panel, and the SITOP PSU8600 power supply module are commonly reviewed during the same maintenance campaign to ensure the entire control architecture is current and supportable.
Q: Can the 6SR4902-0AG00-0AM1 be installed without modifying existing cabinet wiring?
A: Yes. The cell uses the same input transformer tap connections and fiber-optic interface as the original GH180 cell. No rewiring of the power or signal circuits is required for a like-for-like replacement.
Q: Does the GH180 Control Unit need to be re-parameterized after cell replacement?
A: No re-parameterization is required when replacing with an OEM-specification cell. The CU recognizes the new cell automatically via the fiber-optic cell management protocol. If the CU firmware is outdated, a firmware update is recommended but is independent of the cell swap.
Q: What communication protocols does the GH180 support, and does the replacement cell affect them?
A: The GH180 supports PROFIBUS DP and PROFINET IO at the drive level. The AC Power Cell communicates internally via the GH180 proprietary fiber-optic protocol. Replacing the cell does not affect the upstream PROFIBUS/PROFINET configuration or the DCS/SCADA integration.
Q: Is the 6SR4902-0AG00-0AM1 compatible with all GH180 cabinet sizes and voltage ratings?
A: The 6SR4902-0AG00-0AM1 is rated for a specific voltage and current class within the GH180 range. Customers should confirm the cell slot designation, input voltage tap, and rated current against their drive nameplate and GH180 configuration documentation before ordering. TOPNLMS technical support can assist with cross-referencing.
Q: How long does installation and commissioning typically take?
A: A trained drive service engineer can complete a single-cell swap in 2–4 hours under normal conditions, including isolation, mechanical removal, installation, fiber-optic reconnection, and functional test. Full drive recommissioning with load testing may extend the window to one shift.
Q: What physical space is required in the GH180 cabinet?
A: The 6SR4902-0AG00-0AM1 is a direct form-factor replacement for the original GH180 cell. No cabinet modifications, additional mounting hardware, or ventilation changes are required.
Every Siemens 6SR4902-0AG00-0AM1 unit shipped by TOPNLMS is covered by a 12-month warranty from the date of delivery. Prior to dispatch, each unit undergoes a pre-shipment functional inspection to verify electrical integrity, fiber-optic interface operation, and physical condition. Units that do not meet our quality criteria are quarantined and not offered for sale.
In the event of a warranty claim, TOPNLMS provides a replacement unit or full refund based on the fault assessment. Our after-sales response target is within 24 hours of claim submission. We support customers through the fault documentation process and, where required, can provide test reports and inspection records to assist with insurance or maintenance audit requirements.
For urgent replacement needs, TOPNLMS offers expedited shipping from Xiamen, China, with DHL Express, FedEx International Priority, and sea freight options available depending on lead-time requirements. Export documentation, commercial invoices, and packing lists are prepared to facilitate smooth customs clearance in the destination country.
To place an order, request a quotation, or obtain technical clarification, contact our team directly:
Click Quote This Model and the Part Number field will auto-fill with 6SR4902-0AG00-0AM1.