Siemens 6SL3120-1TE24-5AA3 Original S120 Motor Module
6SL3120-1TE24-5AA3Original Siemens 6SL3120-1TE24-5AA3 SINAMICS S120 Single Motor Module 45A Booksize. Genuine spare, tested, 12-month warranty. Fast global shipping from TOPNLMS.
Request availability, condition, lead time and export shipping details for 6SL3055-0AA00-2TA0.
Send this exact part number, quantity and destination country. TOPNLMS will confirm availability, condition and export lead time before quotation.
The Siemens 6SL3055-0AA00-2TA0 is a Technology Module (TM) designed for the SINAMICS S120 drive system — one of Siemens’ most widely deployed servo and vector drive platforms in precision manufacturing, CNC machining, packaging, printing, and process automation. As a genuine industrial spare, this module plays a critical role in maintaining system uptime, preserving drive performance, and extending the operational life of existing S120 installations without requiring a full system overhaul.
For maintenance engineers and procurement teams managing aging SINAMICS S120 drive cabinets, securing a verified replacement for the 6SL3055-0AA00-2TA0 is a high-priority action. This Technology Module interfaces directly with the S120 Control Unit — typically a CU320-2 DP or CU320-2 PN — and expands the drive’s functional capability for technology-specific applications including cam synchronization, electronic gearbox, and position control. Loss of this module results in immediate loss of those functions, often triggering unplanned downtime in synchronized multi-axis systems.
At TOPNLMS, we stock the 6SL3055-0AA00-2TA0 as a ready-to-ship industrial spare, pre-tested and verified against Siemens factory specifications. Each unit ships with a 12-month warranty, full inspection documentation, and is packaged to IEC transport standards to prevent ESD and mechanical damage in transit.
| Parameter | Specification |
|---|---|
| Part Number | 6SL3055-0AA00-2TA0 |
| Product Family | SINAMICS S120 |
| Module Type | Technology Module (TM) |
| Compatible Control Units | CU320-2 DP, CU320-2 PN, CU310-2 DP/PN |
| Communication Interface | DRIVE-CLiQ |
| Supply Voltage | 24 V DC (via DRIVE-CLiQ or external) |
| Mounting | DIN rail / booksize cabinet mounting |
| Operating Temperature | 0 °C to +55 °C |
| Protection Class | IP20 |
| Country of Origin | Germany |
| Firmware Compatibility | SINAMICS S120 firmware V4.x and above |
| Warranty | 12 Months (TOPNLMS) |
| Shipping | In stock — ships within 1–3 business days |
A well-structured preventive maintenance program for SINAMICS S120 drive systems goes far beyond replacing a single module. When scheduling a maintenance window to replace or inspect the 6SL3055-0AA00-2TA0, experienced maintenance engineers typically audit the entire drive cabinet to identify components approaching end-of-life or showing early signs of degradation.
The DRIVE-CLiQ topology that connects the 6SL3055-0AA00-2TA0 to the control unit relies on the integrity of DRIVE-CLiQ cables (such as the 6SL3060 series). Damaged or aged cables are a common root cause of intermittent communication faults that are often misdiagnosed as module failure. Replacing the Technology Module without inspecting the DRIVE-CLiQ wiring harness is a missed opportunity.
The CU320-2 DP or CU320-2 PN Control Unit itself should be evaluated during the same maintenance cycle. If the control unit firmware is outdated or the unit shows signs of capacitor aging, a proactive replacement prevents a secondary failure shortly after the Technology Module is restored. Similarly, the 6SL3100-0BE25-5AB0 Active Line Module or equivalent infeed module in the same cabinet should be inspected for cooling fan condition and DC bus capacitor health.
Power supply integrity is equally critical. The 6EP1333-3BA00 SITOP PSU300S 24 V DC power supply, commonly used to power S120 auxiliary circuits and control electronics, should be load-tested during the maintenance window. A degraded SITOP supply can cause erratic behavior in the Technology Module and other DRIVE-CLiQ devices, leading to false fault codes that waste diagnostic time.
For multi-axis S120 systems, the 6SL3120-1TE21-8AA3 Single Motor Module and associated 6SL3040-1MA00-0AA0 Control Interface Module should be included in the inspection checklist. These components share the same DC bus and DRIVE-CLiQ network as the Technology Module, and a failure in any one of them can cascade across the axis group.
Terminal block integrity — particularly the 6ES7392-1AJ00-0AA0 front connector or equivalent Siemens terminal accessories used in the S120 cabinet — should be checked for oxidation, loose crimps, and thermal discoloration. These are low-cost components that are frequently overlooked but are responsible for a disproportionate share of intermittent faults in high-vibration environments.
Finally, if the S120 system interfaces with a SIMATIC S7-300 or S7-1500 PLC via PROFIBUS DP or PROFINET, the communication module on the PLC side — such as a 6GK7343-1EX30-0XE0 CP 343-1 or 6GK7543-1AX00-0XE0 CP 1543-1 — should be verified for firmware compatibility and port integrity. A coordinated maintenance approach that covers the full signal chain from PLC to drive to motor significantly reduces the risk of repeat failures after the Technology Module replacement.
The 6SL3055-0AA00-2TA0 is a long-lifecycle Siemens component, but availability on the open market can be inconsistent — particularly for facilities that operate multiple S120 systems and require fast turnaround during unplanned outages. TOPNLMS maintains buffer stock of this module specifically to support emergency replacement scenarios where lead times from authorized distributors are unacceptable.
For facilities transitioning from older SINAMICS S110 or MASTERDRIVES MC systems to the S120 platform, the 6SL3055-0AA00-2TA0 is often a required addition to the new drive cabinet to replicate technology functions that were previously handled by legacy positioning boards. In these migration scenarios, the Technology Module allows the S120 system to assume cam, gearbox, and synchronization functions without requiring a new PLC program architecture — preserving existing motion logic while upgrading the drive hardware.
Procurement teams managing multi-site operations are encouraged to establish a minimum stock level of one 6SL3055-0AA00-2TA0 per S120 installation that relies on technology functions. The module’s compact form factor and stable firmware compatibility across S120 generations make it an efficient spare to hold. TOPNLMS offers volume pricing for multi-unit orders and can provide batch inspection reports upon request.
Q1: Is the 6SL3055-0AA00-2TA0 compatible with all SINAMICS S120 firmware versions?
The module is compatible with SINAMICS S120 firmware V4.4 and above. For systems running earlier firmware, a firmware update via STARTER or TIA Portal is recommended before installation. TOPNLMS can advise on firmware compatibility based on your control unit order number.
Q2: Can this module be installed as a direct drop-in replacement without reprogramming?
In most cases, yes. The 6SL3055-0AA00-2TA0 is recognized automatically by the S120 Control Unit via DRIVE-CLiQ. However, if the replacement unit has a different firmware version than the original, a brief recommissioning step using STARTER or TIA Portal Startdrive may be required to align the drive object configuration. TOPNLMS provides pre-shipment firmware verification on request.
Q3: What is included in the 12-month warranty?
All units supplied by TOPNLMS carry a 12-month warranty from the date of shipment. This covers manufacturing defects and functional failures under normal operating conditions. Each unit undergoes pre-shipment functional testing, and a test report is available upon request. Warranty claims are handled directly by TOPNLMS with a target response time of 24 hours.
Q4: How quickly can the module be shipped, and what documentation is provided?
In-stock units ship within 1–3 business days via DHL Express, FedEx International Priority, or equivalent tracked courier. Each shipment includes a commercial invoice, packing list, and certificate of conformity. For customs-sensitive destinations, additional documentation such as a country-of-origin certificate (Germany) can be provided on request.
© 2026 TOPNLMS. All rights reserved.