Siemens 6SL3120-1TE24-5AA3 Original S120 Motor Module
6SL3120-1TE24-5AA3Original Siemens 6SL3120-1TE24-5AA3 SINAMICS S120 Single Motor Module 45A Booksize. Genuine spare, tested, 12-month warranty. Fast global shipping from TOPNLMS.
Request availability, condition, lead time and export shipping details for 6SE7021-0EA51-Z.
Send this exact part number, quantity and destination country. TOPNLMS will confirm availability, condition and export lead time before quotation.
The Siemens 6SE7021-0EA51-Z C33+F01+G91 is a 4 kW vector-control AC variable frequency drive from the SIMOVERT MASTERDRIVES (6SE70) series — a platform that has reached end-of-life and is no longer in active production. For facilities still operating MASTERDRIVES-based control architectures, sourcing a verified replacement or executing a controlled upgrade is now a critical operational priority. TOPNLMS supplies this unit as a genuine replacement module, fully tested and backed by a 12-month warranty, to support both emergency swap-out and planned migration projects.
The option codes embedded in the SKU define the exact hardware configuration: C33 indicates an external fan cooling assembly, F01 designates the basic operator panel (OP1S-compatible interface), and G91 confirms the integrated encoder evaluation board for closed-loop speed feedback. These options are critical when matching a replacement unit to an existing installation — mismatched option codes will result in wiring incompatibilities, encoder signal loss, or operator panel communication failures. Every unit shipped by TOPNLMS is verified against the full option code string before dispatch.
| Parameter | Original: 6SE7021-0EA51-Z C33+F01+G91 | Replacement / Upgrade Path |
|---|---|---|
| Series | SIMOVERT MASTERDRIVES VC (6SE70) | Direct replacement unit (same SKU) or SINAMICS G120 / S120 upgrade |
| Power Rating | 4 kW (5.5 HP) | 4 kW matched; SINAMICS PM240-2 power module available in equivalent rating |
| Control Mode | Vector Control (VC) | Vector / Sensorless Vector / Servo (SINAMICS S120 CU320-2) |
| Encoder Interface (G91) | Incremental encoder, HTL/TTL via SMC10/SMC20 equivalent | SMC20 Sensor Module Cabinet-Mounted for SINAMICS S120 |
| Operator Panel (F01) | OP1S basic panel, USS protocol | IOP-2 Intelligent Operator Panel for SINAMICS G120 |
| Cooling (C33) | External fan assembly, forced air | Equivalent forced-air cooling; cabinet ventilation layout unchanged |
| Communication Protocol | PROFIBUS DP (CB15 option) / USS | PROFIBUS / PROFINET / EtherNet/IP via SINAMICS CU250S-2 or G120 CU240E-2 |
| Mounting / Form Factor | Booksize chassis, DIN rail or panel mount | SINAMICS G120 booksize; same cabinet footprint in most configurations |
| Installation Wiring | Standard IEC terminal block layout | Terminal mapping guide provided; no rewiring required for direct replacement |
| Warranty | — | 12-Month Warranty on all TOPNLMS-supplied units |
A successful migration from a SIMOVERT MASTERDRIVES installation rarely involves swapping only the drive unit. The surrounding system architecture — power distribution, feedback devices, communication infrastructure, and operator interfaces — must all be evaluated for compatibility. TOPNLMS supports complete bill-of-materials sourcing for MASTERDRIVES-to-SINAMICS migration projects.
When replacing the 6SE7021-0EA51-Z in a closed-loop vector application, the encoder feedback chain must be preserved. The original G91 encoder board interfaces with incremental encoders via HTL or TTL signals. In a SINAMICS S120 upgrade, this function is taken over by the SMC20 Sensor Module Cabinet-Mounted, which connects to the CU320-2 Control Unit over DRIVE-CLiQ. If the existing encoder is a standard 1024 ppr HTL type, it can typically be retained without replacement, significantly reducing rewiring scope.
For sites running PROFIBUS DP networks — common in MASTERDRIVES installations paired with Siemens S7-300 or S7-400 PLCs — the communication module must be matched carefully. The original drive may carry a CB15 PROFIBUS communication board. In a SINAMICS G120 replacement, the equivalent is the CU240E-2 DP Control Unit, which provides native PROFIBUS DP connectivity and supports the same GSD file-based network configuration used in STEP 7 or TIA Portal projects. This allows the existing PLC program to communicate with the new drive with minimal parameter remapping.
Power supply integrity is another migration checkpoint. The MASTERDRIVES 6SE70 series draws from a standard three-phase 400 V AC supply. The replacement unit or SINAMICS equivalent uses the same supply voltage range, so the existing line reactor (e.g., 4EP3600-8US00 or equivalent) and input fusing can typically be retained. If the installation includes a SIMOVERT MASTERDRIVES Rectifier Unit in a common DC bus topology, the migration plan must account for DC link compatibility before selecting the SINAMICS replacement architecture.
Operator interface continuity is addressed through the F01 option. The original OP1S panel communicates over USS protocol. In a direct replacement scenario, the same OP1S panel can be reused. In a full SINAMICS G120 upgrade, the IOP-2 Intelligent Operator Panel provides equivalent local control and parameter access, with a familiar menu structure that reduces retraining time for maintenance personnel.
For I/O-intensive applications, the terminal expansion capabilities of the replacement platform should be reviewed. The MASTERDRIVES 6SE70 provides a fixed set of digital and analog I/O terminals. SINAMICS G120 with a CU250S-2 Control Unit offers expanded I/O, including additional digital inputs, safe torque off (STO) terminals, and encoder interfaces — all within a similar cabinet footprint. Where additional I/O is required, SIMATIC ET 200SP distributed I/O modules can be integrated over PROFINET to extend the control system without expanding the main control cabinet.
Terminal blocks and wiring accessories from the SIRIUS 3RT / 3RV range are commonly found in the same control cabinets as MASTERDRIVES installations. These components are fully compatible with SINAMICS-based replacements and do not require modification during the drive swap.
Q: Can I reuse the existing motor wiring when replacing the 6SE7021-0EA51-Z?
A: Yes, in most cases. The motor cable terminations and shielding requirements for a 4 kW SINAMICS replacement are identical to the MASTERDRIVES original. Verify cable cross-section against the new drive’s output current rating and confirm that the motor cable length does not exceed the drive manufacturer’s maximum without an output reactor.
Q: Will my existing PROFIBUS DP network configuration work with the replacement drive?
A: If you are installing a direct same-SKU replacement, the PROFIBUS node address and GSD file remain unchanged — no PLC program modification is required. For a SINAMICS G120 upgrade, a new GSD file must be imported into TIA Portal or STEP 7, and drive parameters must be remapped. TOPNLMS can provide parameter migration guidance upon request.
Q: The original drive has a G91 encoder board. How do I handle encoder feedback in the replacement?
A: For a direct replacement unit (same SKU), the G91 encoder board is included and the existing encoder wiring connects identically. For a SINAMICS S120 upgrade, the SMC20 Sensor Module replaces the G91 function. Encoder signal type (HTL/TTL), resolution (ppr), and supply voltage must be confirmed before selecting the SMC20 variant.
Q: How much physical space does the replacement unit require in the control cabinet?
A: The 6SE7021-0EA51-Z occupies a standard MASTERDRIVES booksize chassis footprint. A direct replacement unit fits the same mounting position. SINAMICS G120 booksize units have a comparable form factor; however, cabinet depth and busbar clearance should be verified against the site-specific cabinet layout before committing to an upgrade.
Q: What is the lead time and how is the unit tested before shipment?
A: Units in stock ship within 1–3 business days from Xiamen. Each unit undergoes power-on functional testing and visual inspection before dispatch. A test report is available upon request. Express international shipping is available to minimize site downtime.
All 6SE7021-0EA51-Z C33+F01+G91 units supplied by TOPNLMS are covered by a 12-month warranty from the date of shipment. This warranty covers manufacturing defects, functional failures under normal operating conditions, and component-level faults identified during installation or commissioning. Units that fail within the warranty period are eligible for replacement or repair at no additional cost to the buyer.
Pre-shipment testing includes power-on verification, output voltage balance check, control board communication test, and visual inspection of all connectors, terminals, and option boards. Units are packed in anti-static foam with moisture-barrier packaging to prevent transit damage. Shipping documentation includes a packing list, test record, and — where applicable — original manufacturer documentation.
For procurement teams managing planned maintenance or emergency replacement scenarios, TOPNLMS maintains stock of critical MASTERDRIVES-era components to support rapid dispatch. Volume orders and blanket purchase agreements are accommodated. After-sales technical support is available via email and phone for installation, commissioning, and parameter configuration queries.
To confirm stock availability, request a quotation, or discuss a migration project, contact the TOPNLMS technical sales team directly.
Click Quote This Model and the Part Number field will auto-fill with 6SE7021-0EA51-Z.