Language English USD Currency
Call WhatsApp RFQ
Siemens Industrial Automation Part

Siemens 6ES7658-2GG00-0XB0 WinCC Web Server Upgrade Solution

Request availability, condition, lead time and export shipping details for 6ES7658-2GG00-0XB0.

Siemens

6ES7658-2GG00-0XB0

Send this exact part number, quantity and destination country. TOPNLMS will confirm availability, condition and export lead time before quotation.

BrandSiemens
Part Number6ES7658-2GG00-0XB0
CategoryHMI
ConditionAvailability Check
Lead TimeRFQ Confirmation
SeriesWinCC
ShippingExport packing available
Model checked before quotation Condition and packing confirmed Fast RFQ response by sales engineer

Product Overview

Siemens 6ES7658-2GG00-0XB0 WinCC Web Server Upgrade Solution: Seamless Transition from Legacy SCADA Systems

The Siemens 6ES7658-2GG00-0XB0 is a SIMATIC WinCC Web Server License designed for industrial SCADA environments running on the S7-400 platform and compatible WinCC runtime architectures. As legacy WinCC installations approach end-of-support milestones and older web server license models are discontinued, plant engineers and system integrators face increasing pressure to migrate to current licensing structures without disrupting live production environments. This replacement and upgrade solution is engineered to support that transition with minimal downtime and maximum compatibility assurance.

Whether your facility is running an aging WinCC V6.x or V7.x deployment on a SIMATIC S7-400 rack, or managing a distributed SCADA topology with multiple WinCC clients and servers, the 6ES7658-2GG00-0XB0 Web Server License integrates directly into your existing WinCC project structure. No re-engineering of the HMI tag database is required. The license activates web-based visualization capabilities, enabling operators to access real-time process data through standard browsers without modifying the underlying PLC program on the S7-400 CPU or reconfiguring the MPI/PROFIBUS DP communication network.

During migration planning, engineers frequently encounter compatibility questions around the WinCC project server, the WinCC client licensing model, and the interaction between the web server component and the WinCC Runtime license. The 6ES7658-2GG00-0XB0 is fully compatible with WinCC Runtime licenses in the same generation family, and it operates alongside WinCC DataMonitor and WinCC WebNavigator components without conflict. If your existing installation uses a WinCC Connectivity Pack for OPC DA/UA data exchange with third-party systems, the web server license does not interfere with those communication channels.

For facilities upgrading from a standalone WinCC single-station configuration to a client-server architecture, this license supports the web server role within a multi-client WinCC topology. The transition typically involves reassigning the WinCC project to a dedicated server node, installing the appropriate WinCC Server license, and then activating the Web Server License on the same machine. The 6ES7658-2GG00-0XB0 fits precisely into this architecture without requiring changes to the S7-400 hardware configuration, the CP 443-1 Ethernet communication processor, or the existing PROFIBUS DP I/O network connecting remote ET 200M distributed I/O stations.

Physical installation is straightforward. The license is delivered as an Automation License Manager (ALM) key, compatible with Siemens’ standard license transfer and backup procedures. Engineers familiar with SIMATIC WinCC licensing workflows will find the activation process identical to other WinCC component licenses. The license can be transferred between machines using the ALM tool, supporting hardware replacement scenarios where the WinCC server PC must be swapped due to hardware failure or planned infrastructure refresh.

In retrofit projects where the control room PC running WinCC is being replaced — for example, migrating from a Windows XP or Windows 7 host to a current Windows Server environment — the 6ES7658-2GG00-0XB0 license transfers cleanly to the new hardware. This is particularly relevant for facilities that are simultaneously upgrading their S7-400 CPUs to S7-400H redundant controllers or migrating I/O to ET 200SP distributed peripherals, as the WinCC project can be updated incrementally without requiring a full SCADA replacement.

Compatibility Comparison Table

Parameter Legacy / Replaced Model 6ES7658-2GG00-0XB0 (This Unit)
License Type WinCC Web Server (prior generation) WinCC Web Server License – current generation
Compatible WinCC Version WinCC V6.x / V7.0 WinCC V7.x (compatible generation)
PLC Platform SIMATIC S7-300 / S7-400 SIMATIC S7-400 / S7-400H (compatible)
Communication Protocol MPI / PROFIBUS DP / Industrial Ethernet Industrial Ethernet (TCP/IP), MPI compatible
License Delivery Physical dongle / legacy ALM Automation License Manager (ALM) key
OS Compatibility Windows XP / Windows 7 Windows 7 / Windows Server 2008 R2 and above
Web Client Access Limited / IE-only Standard browser-based access
Installation Space Rack-mounted dongle or USB Software license – no additional rack space required
Replacement Recommendation Direct drop-in license replacement ✔ Recommended upgrade path
Warranty 12-Month Warranty included

Seamless Upgrade Solutions

A successful WinCC web server migration rarely involves a single component. In practice, the 6ES7658-2GG00-0XB0 is deployed alongside a coordinated set of hardware and software upgrades. On the PLC side, facilities running S7-400 CPUs such as the 6ES7414-2XK05-0AB0 or 6ES7416-3XR05-0AB0 will find that the WinCC web server license integrates without any CPU firmware changes. The CP 443-1 Advanced Ethernet communication processor (6GK7443-1EX30-0XE0) handles the Industrial Ethernet link between the S7-400 rack and the WinCC server, and this communication path remains unchanged after the license upgrade.

For distributed I/O, ET 200M interface modules such as the IM 153-2 connected via PROFIBUS DP continue to operate transparently. The WinCC web server license does not alter the I/O communication layer. Similarly, if the installation includes a WinCC DataMonitor license for Excel-based reporting or a WinCC Connectivity Pack for OPC UA data export to MES systems, these components coexist with the 6ES7658-2GG00-0XB0 without licensing conflicts.

In control rooms where the operator interface is being modernized, the WinCC web server license enables migration from dedicated WinCC client PCs to thin-client or browser-based workstations, reducing hardware costs. If the project also involves upgrading the SIMATIC Panel HMI — for example, replacing a TP 1500 Comfort Panel with a newer generation — the WinCC web server provides a parallel visualization path during the transition period, allowing operators to monitor processes from both the panel and web clients simultaneously.

Power supply integrity is critical during any SCADA migration. The SITOP PSU100S 24V DC power supply modules commonly used in S7-400 control cabinets remain fully compatible, and no power infrastructure changes are required when adding the web server license. For projects that include signal isolation between field instruments and the PLC I/O, SIEMENS SITRANS signal isolators and barriers in the same cabinet continue to function without modification.

Programming cable connectivity — such as the PC Adapter USB A2 (6ES7972-0CB20-0XA0) used for S7-400 MPI programming — is unaffected by the WinCC license change, ensuring that maintenance engineers can continue to use existing tools for PLC program uploads and downloads throughout the migration process.

Retrofit Guidance FAQ

Q: Will the 6ES7658-2GG00-0XB0 work with my existing WinCC V7.x project without reconfiguration?
A: Yes. The Web Server License activates the web server component within your existing WinCC project. No tag database changes or project restructuring are required. Simply install the license via the Automation License Manager and enable the WinCC Web Server in the project settings.

Q: Does upgrading the web server license require changes to the S7-400 PLC program?
A: No. The WinCC web server operates at the SCADA layer and communicates with the S7-400 CPU through the existing WinCC channel drivers (S7 Protocol Suite or Industrial Ethernet). The PLC program, data blocks, and I/O configuration remain unchanged.

Q: Is the license compatible with PROFIBUS DP-based I/O networks?
A: Yes. The WinCC web server license does not interact with the PROFIBUS DP network directly. The S7-400 CPU manages PROFIBUS DP communication with ET 200M or ET 200S distributed I/O independently of the WinCC licensing layer.

Q: Can this license be transferred to a new server PC if we replace the WinCC server hardware?
A: Yes. The license is managed through Siemens Automation License Manager (ALM) and can be transferred to a new PC using standard ALM procedures. This supports hardware refresh scenarios without requiring a new license purchase.

Q: What physical space does this license require in the control cabinet?
A: None. The 6ES7658-2GG00-0XB0 is a software license delivered via ALM. It requires no DIN rail space, no rack slot, and no additional wiring in the control cabinet.

Q: How does this license interact with OPC UA communication to MES or ERP systems?
A: The WinCC Web Server License is independent of OPC UA connectivity. If your installation uses a WinCC Connectivity Pack for OPC UA data exchange, both licenses operate in parallel without conflict.

Warranty Assurance

Every Siemens 6ES7658-2GG00-0XB0 WinCC Web Server License supplied by TOPNLMS is backed by a 12-month warranty from the date of shipment. Prior to dispatch, each unit undergoes functional verification to confirm license integrity and ALM compatibility. In the event of a license activation failure or compatibility issue identified within the warranty period, TOPNLMS provides direct replacement support with priority processing.

Our procurement assurance covers: verified original Siemens licensing, pre-shipment inspection, secure packaging to prevent license key damage in transit, and full documentation including the ALM license file and certificate of authenticity where applicable. Orders are typically processed and shipped within 2–5 business days from our Xiamen warehouse, with express shipping options available for urgent replacement requirements.

For volume procurement, system integrators and OEM partners are encouraged to contact our technical sales team directly to discuss lead times, quantity pricing, and project-specific compatibility verification. Our team has direct experience supporting WinCC migration projects across manufacturing, energy, water treatment, and process industries.

After-sales technical support is available via email and phone throughout the warranty period. If a replacement unit is required, TOPNLMS initiates the replacement process within 24 business hours of a confirmed warranty claim, minimizing disruption to your production environment.

Quick Inquiry

Click Quote This Model and the Part Number field will auto-fill with 6ES7658-2GG00-0XB0.