Siemens A5E01161647 Ruggedized CP Communication Module
A5E01161647Siemens A5E01161647 SIMATIC S7 CP communication module. Rugged, EMC-rated, tested. 12-month warranty. In stock at TOPNLMS — fast global shipping.
Request availability, condition, lead time and export shipping details for 6ES7 153-1AA03-0XB0.
Send this exact part number, quantity and destination country. TOPNLMS will confirm availability, condition and export lead time before quotation.
The Siemens 6ES7 153-1AA03-0XB0 is a PROFIBUS DP Bus Terminator designed for use with the ET 200M distributed I/O station, specifically paired with the IM 153-1 interface module. As industrial facilities continue to modernize aging SIMATIC S5 and early S7-300 control architectures, this terminator plays a critical role in maintaining signal integrity at the physical end of a PROFIBUS DP segment — preventing reflections that can cause intermittent communication faults, CRC errors, and unplanned shutdowns.
At TOPNLMS, we stock the 6ES7 153-1AA03-0XB0 as a direct replacement and upgrade solution for facilities transitioning from discontinued or end-of-life PROFIBUS configurations. Whether you are replacing a failed terminator on an active production line or pre-positioning spares for a planned retrofit, our inventory is tested, verified, and ready to ship.
| Parameter | 6ES7 153-1AA03-0XB0 (This Unit) | Typical Legacy / Replaced Units |
|---|---|---|
| Product Type | PROFIBUS DP Bus Terminator | External resistor networks / passive terminators |
| Compatible Interface Module | IM 153-1 (6ES7 153-1AA03-0XB0) | IM 153-1 earlier firmware revisions |
| Station Platform | ET 200M Distributed I/O | ET 200M / ET 200B legacy configurations |
| Communication Protocol | PROFIBUS DP (IEC 61158) | PROFIBUS DP / MPI (adapter required for MPI) |
| Installation Method | Integrated snap-on terminator on IM 153-1 rail | External DB9 plug-in terminator or DIP switch |
| Wiring Compatibility | Standard PROFIBUS DP cable (IEC 61158-2) | Same — no rewiring required |
| Supply Voltage | Powered via backplane (no external supply needed) | Some legacy units require separate 5 V supply |
| DIN Rail / Rack Fit | Standard S7-300 DIN rail, ET 200M rack | Compatible — same rail pitch |
| Replacement Recommendation | Direct drop-in for same SKU; verify IM firmware | Check IM 153-1 firmware ≥ V3.x for full compatibility |
| Warranty | 12-Month Warranty — covered from date of shipment | |
A successful PROFIBUS DP segment migration involves more than swapping a single terminator. When upgrading or replacing the 6ES7 153-1AA03-0XB0, engineers typically review the entire ET 200M station to ensure all components are current and mutually compatible.
The IM 153-1 interface module itself is the first component to verify — its firmware version determines which bus terminator revisions are supported and whether the station can participate in a PROFIBUS DP network alongside newer S7-300 or S7-400 CPUs. In systems where the IM 153-1 has been upgraded to support expanded I/O, the associated SM 321 digital input modules and SM 322 digital output modules mounted on the ET 200M rack must also be confirmed compatible with the new terminator’s bus timing parameters.
For facilities running mixed PROFIBUS and PROFINET architectures — a common scenario during phased S7-300 to S7-1500 migrations — a PN/DP coupler or IE/PB Link PN IO is often installed alongside the ET 200M station to bridge legacy PROFIBUS segments into the new PROFINET backbone. In these topologies, the bus terminator at each physical PROFIBUS segment end, including the 6ES7 153-1AA03-0XB0, must be correctly installed to prevent signal degradation that would otherwise cause the coupler to report station failures.
Power supply integrity is equally important. The PS 307 power supply modules feeding the ET 200M rack should be inspected during any terminator replacement, as aging capacitors in older PS 307 units can introduce voltage ripple that mimics PROFIBUS communication errors. Replacing the terminator without addressing a marginal power supply can lead to misdiagnosis and repeated failures.
In control cabinet environments where space is constrained, the 6ES7 390-1AE80-0AA0 profile rail and associated bus connectors (such as the 6ES7 972-0BA52-0XA0 with integrated terminating resistor) are commonly reviewed alongside the IM 153-1 terminator to ensure the full segment is properly closed at both ends. Leaving one end unterminated — even with the correct 6ES7 153-1AA03-0XB0 installed at the other — will still produce reflection-induced errors.
For sites performing a full ET 200M station rebuild or rack replacement, the 6ES7 195-7HD10-0XA0 bus module and 6ES7 195-7HB00-0XA0 terminating bus module are the standard companions to the IM 153-1 and its bus terminator, completing the internal backplane bus and ensuring correct signal termination at the rack level as well as the segment level.
Finally, during commissioning and post-replacement testing, a PROFIBUS DP diagnostic repeater (such as the 6ES7 972-0AB01-0XA0) is invaluable for verifying segment quality, measuring cable attenuation, and confirming that the newly installed 6ES7 153-1AA03-0XB0 has restored correct termination impedance across the bus.
Q: Can I replace the 6ES7 153-1AA03-0XB0 without rewiring the PROFIBUS cable?
A: Yes. The bus terminator connects to the IM 153-1 interface module via the integrated backplane connector — no field wiring changes are required. Ensure the PROFIBUS DP cable at the segment end is connected to the IM 153-1’s bus connector, not to the terminator directly.
Q: Does the replacement terminator require any programming changes in STEP 7 or TIA Portal?
A: No software changes are required. The 6ES7 153-1AA03-0XB0 is a passive hardware component. After physical replacement, the PROFIBUS master (S7-300 or S7-400 CPU) will automatically re-establish communication with the ET 200M station without any configuration modification.
Q: What PROFIBUS baud rates are supported?
A: The 6ES7 153-1AA03-0XB0 supports all standard PROFIBUS DP baud rates from 9.6 kbps up to 12 Mbps, consistent with IEC 61158. No baud rate restrictions apply when used with the IM 153-1 at firmware V3.x or later.
Q: How do I confirm the terminator is the cause of my PROFIBUS errors?
A: Use a PROFIBUS DP diagnostic repeater or a bus monitor tool to measure segment impedance and signal quality. A missing or failed terminator typically produces reflection signatures visible as waveform distortion at the segment end. The SIMATIC Manager or TIA Portal diagnostic buffer will also log station failures and bus errors that correlate with termination faults.
Q: Is this unit compatible with ET 200M stations running in redundant IM configurations?
A: The 6ES7 153-1AA03-0XB0 is designed for standard (non-redundant) IM 153-1 configurations. For redundant ET 200M setups using dual IM 153-2 modules, a different terminator revision is required — please contact us to confirm the correct part number for your redundancy configuration.
Q: What is the physical installation space requirement?
A: The terminator mounts directly onto the IM 153-1 module with no additional DIN rail space required. It occupies no additional width in the control cabinet, making it suitable for dense rack installations where space is at a premium.
Every 6ES7 153-1AA03-0XB0 shipped by TOPNLMS is covered by a 12-month warranty from the date of shipment. Prior to dispatch, each unit undergoes functional verification including visual inspection, connector integrity check, and where applicable, powered communication testing to confirm the module performs within Siemens’ published specifications.
In the event of a confirmed defect within the warranty period, TOPNLMS will arrange a replacement shipment or issue a refund — whichever resolution best minimizes your downtime. Our after-sales response target is within 24 business hours of a warranty claim submission.
We ship globally from Xiamen, China, with standard lead times of 3–7 business days for stocked items. Express courier options (DHL, FedEx, UPS) are available for urgent replacement requirements. All shipments include tracking and commercial invoice documentation suitable for customs clearance.
For bulk procurement, long-term supply agreements, or technical pre-sales consultation on PROFIBUS DP segment design and ET 200M compatibility, contact our engineering sales team directly.
Click Quote This Model and the Part Number field will auto-fill with 6ES7 153-1AA03-0XB0.