Siemens 6ES5955-3NC4 Ruggedized Power Supply Module
6ES5955-3NC4Siemens 6ES5955-3NC4 SIMATIC S5 ruggedized power supply module 5V/9A 24V/1A. In stock, tested, 12-month warranty. Fast global shipping from TOPNLMS.
Request availability, condition, lead time and export shipping details for 6EP3134-0TA00-0AY0.
Send this exact part number, quantity and destination country. TOPNLMS will confirm availability, condition and export lead time before quotation.
The Siemens 6EP3134-0TA00-0AY0 is a SITOP PSU100S series stabilized 24 VDC / 4 A DIN rail power supply designed for industrial control panel applications. As aging SITOP PSU100S units reach end-of-service life or become difficult to source, facilities running Siemens S7-300, S7-400, ET 200M, or ET 200S distributed I/O architectures increasingly require a verified, drop-in replacement that preserves wiring layouts, DIN rail footprint, and output characteristics without forcing a full panel redesign.
This listing provides a direct replacement or upgrade solution for the 6EP3134-0TA00-0AY0, sourced from verified supply channels and tested prior to shipment. Whether your existing unit has failed, is approaching scheduled maintenance, or you are pre-positioning critical spares to reduce unplanned downtime, this module ships ready for immediate installation.
| Parameter | Original: 6EP3134-0TA00-0AY0 | Replacement / Upgrade |
|---|---|---|
| Output Voltage | 24 VDC | 24 VDC (identical) |
| Output Current | 4 A | 4 A (identical) |
| Input Voltage Range | 100–240 VAC / 110–300 VDC | 100–240 VAC / 110–300 VDC |
| Mounting | 35 mm DIN rail (EN 60715) | 35 mm DIN rail (EN 60715) |
| Housing Width | 45 mm | 45 mm (same footprint) |
| Protection Class | IP20 | IP20 |
| Output Terminal | Screw terminal (L+, M) | Screw terminal (L+, M) — direct re-wire |
| Signaling / Status | DC OK LED | DC OK LED |
| Compatible PLC Platforms | S7-300, S7-400, ET 200M, ET 200S | S7-300, S7-400, ET 200M, ET 200S, S7-1500 (with adapter) |
| Replacement Recommendation | — | Direct drop-in; no wiring modification required |
| Warranty | Original OEM warranty (expired on aged units) | 12-Month Warranty from TOPNLMS |
A power supply replacement rarely occurs in isolation. In most S7-300 and ET 200M retrofit projects, the 6EP3134-0TA00-0AY0 is replaced alongside other aging components to restore full system reliability. During the upgrade process, engineers commonly address the Siemens 6ES7307-1EA01-0AA0 PS307 power supply module on the S7-300 rack, which feeds the CPU and I/O modules directly from the same DIN rail section. Replacing both units simultaneously eliminates the risk of a secondary power failure shortly after the primary repair.
For distributed I/O cabinets using ET 200M IM153-2 interface modules, the 24 VDC bus supplied by the 6EP3134-0TA00-0AY0 powers the backplane and all attached signal modules. Verifying that the replacement PSU’s output ripple and hold-up time meet the IM153-2 specifications is a standard commissioning step. Similarly, SM321 digital input modules and SM322 digital output modules mounted on the ET 200M rack draw their field-side supply from the same 24 VDC rail, so confirming terminal block continuity after PSU swap is essential before re-energizing the rack.
In control cabinets where a Siemens CP343-1 Ethernet communication module or a CP341 serial communication module is installed, the 24 VDC supply quality directly affects communication stability. A degraded PSU can introduce voltage sags that cause intermittent PROFIBUS DP or Industrial Ethernet dropouts, which are often misdiagnosed as network or firmware issues. Replacing the 6EP3134-0TA00-0AY0 with a verified unit resolves these symptoms at the source.
For facilities migrating from older S7-300 architectures toward S7-1500 or ET 200SP platforms, the 24 VDC rail infrastructure — including the SITOP PSU100S — can often be retained as-is, since the S7-1500 CPU modules and ET 200SP BaseUnits accept the same 24 VDC supply voltage. This makes the 6EP3134-0TA00-0AY0 replacement a bridge component that supports both legacy maintenance and forward migration without requiring a full cabinet rewire.
Where panel space is constrained, engineers sometimes pair the SITOP PSU100S with a SITOP buffer module (6EP4134-0GB00-0AY0) to extend hold-up time during brief mains interruptions, protecting the CPU from uncontrolled shutdowns. If your existing buffer module is also aging, replacing both units during the same maintenance window minimizes future intervention costs.
Q: Can I replace the 6EP3134-0TA00-0AY0 without modifying existing wiring?
A: Yes. The terminal layout (L+, M output; L, N, PE input) is identical to the original. Loosen the existing terminals, remove the old unit from the DIN rail, clip the replacement in place, and reconnect the same conductors. No ferrule changes or cable extensions are required.
Q: Will this replacement affect my PROFIBUS DP or PROFINET communication?
A: No. The PSU is a passive power source with no protocol involvement. Communication modules such as the CP343-1 or IM153-2 will resume normal operation immediately after the supply voltage stabilizes, typically within 200 ms of power-on.
Q: Is the physical footprint identical for panel space planning?
A: Yes. The 6EP3134-0TA00-0AY0 occupies 45 mm width on a 35 mm DIN rail. The replacement unit maintains the same dimensions, so no panel layout changes or adjacent component repositioning is needed.
Q: Do I need to update my S7-300 hardware configuration in STEP 7 or TIA Portal after replacing the PSU?
A: No software or hardware configuration changes are required. The PSU is not a configurable node in the S7 hardware catalog; it is a field device that the CPU recognizes only through the presence of stable 24 VDC on the backplane supply rail.
Q: What if my original unit shows intermittent DC OK signal drops?
A: Intermittent DC OK faults on an aging SITOP PSU100S typically indicate capacitor degradation or output regulation drift. Replacement is the recommended corrective action. Attempting to repair the original unit in the field is not advised for safety-critical control systems.
Q: Can this unit power both the PLC rack and field devices simultaneously?
A: The 6EP3134-0TA00-0AY0 provides 4 A at 24 VDC (96 W). For installations where the combined load of the CPU rack, I/O modules, and field sensors exceeds this rating, a second PSU or a higher-capacity SITOP unit (e.g., 6EP3136-0TA00-0AY0 at 6 A) should be considered.
Every 6EP3134-0TA00-0AY0 unit shipped by TOPNLMS is covered by a 12-month warranty from the date of delivery. Prior to dispatch, each unit undergoes output voltage verification, load regulation testing, and visual inspection to confirm it meets the original Siemens SITOP PSU100S specification.
If a unit develops a fault within the warranty period under normal operating conditions, TOPNLMS will arrange a replacement shipment or issue a refund based on your preference. Our after-sales response target is within 24 business hours of fault notification. We maintain buffer stock of common SITOP PSU100S variants to support rapid replacement without extended lead times.
For procurement teams requiring documentation, we can provide test records, packing lists, and commercial invoices upon request. Orders are typically dispatched within 1–3 business days from our Xiamen warehouse, with international express options available for urgent maintenance situations.
We understand that unplanned downtime in industrial environments carries significant operational cost. Our procurement assurance model — verified stock, pre-shipment testing, and 12-month warranty coverage — is designed to give maintenance engineers and procurement managers confidence that the replacement unit will perform reliably from day one.
Click Quote This Model and the Part Number field will auto-fill with 6EP3134-0TA00-0AY0.