Siemens 6ES5955-3NC4 Ruggedized Power Supply Module
6ES5955-3NC4Siemens 6ES5955-3NC4 SIMATIC S5 ruggedized power supply module 5V/9A 24V/1A. In stock, tested, 12-month warranty. Fast global shipping from TOPNLMS.
Request availability, condition, lead time and export shipping details for 6EP1334-2AA00.
Send this exact part number, quantity and destination country. TOPNLMS will confirm availability, condition and export lead time before quotation.
The Siemens 6EP1334-2AA00 is a SITOP Modular series 24 VDC / 4 A regulated industrial power supply engineered for continuous-duty operation in demanding manufacturing and process-control environments. As a direct original spare, it delivers the precise output regulation, overload response, and diagnostic signaling that Siemens-designed control cabinets depend on. Replacing a failed or degraded power supply with a genuine 6EP1334-2AA00 eliminates the voltage drift and ripple that can corrupt PLC logic, trigger spurious I/O faults, and ultimately force unplanned shutdowns. For maintenance teams managing aging SIMATIC S7-300, S7-400, or ET 200 distributed I/O installations, keeping a verified 6EP1334-2AA00 on the shelf is one of the highest-value decisions in a spare-parts strategy.
| Parameter | Specification |
|---|---|
| Siemens Part Number | 6EP1334-2AA00 |
| Series | SITOP Modular |
| Input Voltage | AC 120 / 230 V (wide-range), 50/60 Hz |
| Output Voltage | 24 VDC (adjustable 22.8–26.4 V) |
| Output Current | 4 A continuous |
| Output Power | 96 W |
| Efficiency | ≥ 89 % at full load |
| Ripple & Noise | < 50 mV peak-to-peak |
| Protection Class | IP20 (DIN rail mount) |
| Mounting | 35 mm DIN rail (EN 60715) |
| Dimensions (W × H × D) | 50 × 125 × 117 mm |
| Operating Temperature | −25 °C to +70 °C |
| Certifications | CE, UL, cUL, ATEX Zone 2 |
| Compatibility | SIMATIC S7-300 / S7-400 / ET 200M / ET 200S / SITOP PSE series |
| Country of Origin | Germany |
| Warranty | 12 Months — tested and verified before shipment |
Power supply failure is among the most disruptive events in a control cabinet because every downstream component — PLCs, I/O modules, HMIs, and communication gateways — depends on a stable 24 VDC bus. A structured preventive maintenance programme built around the 6EP1334-2AA00 should extend well beyond the power supply itself.
During scheduled cabinet inspections, technicians should simultaneously verify the condition of the SITOP PSE200U 6EP1961-2BA21 selectivity module, which protects individual 24 VDC branch circuits and isolates faults before they cascade to the CPU. Adjacent to the power supply, the Siemens 6ES7321-1BL00-0AA0 SM321 digital input module and 6ES7322-1BL00-0AA0 SM322 digital output module should be inspected for loose terminal connections and discoloration that indicate thermal stress — symptoms often caused by upstream voltage instability.
Communication integrity is equally critical. The Siemens 6GK7343-1EX30-0XE0 CP343-1 Ethernet communication processor and any installed 6ES7341-1AH02-0AE0 CP341 serial communication modules are sensitive to power-rail noise; replacing a degraded power supply frequently resolves intermittent Profibus or Industrial Ethernet dropouts without further intervention. While the cabinet is open, inspect the Siemens 6ES7390-1AE80-0AA0 DIN rail profile and terminal block assemblies — loose or corroded connections on Weidmüller or Phoenix Contact 24 VDC terminal strips are a common secondary cause of voltage drop at the load end.
For installations with safety-critical outputs, the Siemens 3SK1111-1AB30 safety relay module should be function-tested during the same maintenance window. Finally, review the condition of the Siemens 6EP1336-3BA10 SITOP UPS module if an uninterruptible supply buffer is installed — its capacitor bank degrades over time and should be replaced on a 3–5 year cycle regardless of apparent condition. Bundling these checks into a single planned outage maximises uptime and minimises the number of cabinet access events per year.
The 6EP1334-2AA00 is a direct form-fit-function replacement for earlier SITOP variants including the 6EP1334-1SL11 and 6EP1334-2AA01, making it the preferred upgrade path for facilities still operating first-generation SITOP Modular installations. Because it shares the same 50 mm DIN rail footprint and identical terminal layout, field replacement requires no rewiring and can be completed in under 15 minutes by a qualified technician — a critical advantage when every minute of downtime carries production cost.
For sites running parallel redundant power architectures, the 6EP1334-2AA00 pairs directly with the Siemens 6EP1961-2BA21 redundancy module, enabling hot-swap replacement without interrupting the 24 VDC bus. This configuration is strongly recommended for continuous-process industries — food and beverage, pharmaceutical, chemical — where even a brief power interruption triggers a full line restart sequence.
Maintaining one or two 6EP1334-2AA00 units in local stock eliminates the lead-time risk associated with spot procurement during an emergency. Given that original Siemens SITOP components are subject to periodic product lifecycle transitions, securing verified stock now protects against future availability constraints and ensures long-term compatibility with installed SIMATIC infrastructure.
Q1: Is the 6EP1334-2AA00 a genuine original Siemens component?
Yes. Every unit supplied by TOPNLMS is sourced from authorised distribution channels or verified OEM stock. Each unit undergoes output voltage, load regulation, and ripple testing before shipment. A 12-month warranty is included as standard.
Q2: What is the recommended stock quantity for a facility running multiple SITOP Modular installations?
Industry best practice for critical 24 VDC power supplies is a minimum of one spare per five installed units, with a floor of two units regardless of installation size. For continuous-process facilities, a higher ratio is advisable given the cost of unplanned downtime relative to the cost of the spare.
Q3: How do I verify compatibility with my existing SIMATIC S7-300 or ET 200 installation before installation?
Confirm that your installation requires a 24 VDC / 4 A supply on a 35 mm DIN rail. The 6EP1334-2AA00 is compatible with all standard SIMATIC S7-300 CPU and signal module racks, ET 200M interface modules, and any 24 VDC load up to 96 W. If your load exceeds 4 A, consider the 6EP1334-3BA10 (10 A) or 6EP1336-3BA10 (20 A) variants.
Q4: What does the pre-shipment test cover and what documentation is provided?
Each 6EP1334-2AA00 is tested for output voltage accuracy (24 VDC ± 1 %), full-load current delivery (4 A), output ripple (< 50 mV), and overload protection response. Units are shipped in anti-static packaging with a test confirmation slip. The 12-month warranty covers component failure under normal operating conditions and is supported by TOPNLMS after-sales service.
Click Quote This Model and the Part Number field will auto-fill with 6EP1334-2AA00.