Product Overview
SIEMENS 3ES7307-1EA01-0AA0 PS307 5A: Seamless Replacement & Smooth Transition for S7-300 Control Systems
The SIEMENS 3ES7307-1EA01-0AA0 is a PS307 series 5A regulated DC 24V power supply module designed for integration into SIMATIC S7-300 automation systems. As legacy S7-300 installations approach end-of-life or face discontinued spare parts availability, plant engineers and procurement teams increasingly require a reliable, drop-in replacement that preserves existing wiring infrastructure, DIN rail mounting geometry, and backplane power distribution architecture. This listing provides a verified, tested replacement unit with full compatibility documentation and a 12-month warranty, enabling your facility to execute a controlled migration with minimal disruption to production schedules.
Whether you are replacing a failed unit on an emergency basis or executing a planned lifecycle upgrade across multiple control cabinets, the 3ES7307-1EA01-0AA0 delivers the same 120/230V AC input, 24V DC / 5A output specification as the original factory-installed module. The unit mounts directly onto standard 35mm DIN rail within the S7-300 rack assembly and connects to the backplane bus without requiring any additional adapter hardware. Field engineers report that terminal block wiring from the original PS307 unit transfers directly, eliminating re-termination labor and reducing commissioning time to under 30 minutes per cabinet.
Compatibility Comparison Table
| Parameter |
Original / Legacy Unit |
Replacement: 3ES7307-1EA01-0AA0 |
| Part Number |
6ES7307-1EA01-0AA0 (original) |
3ES7307-1EA01-0AA0 (replacement) |
| Series |
SIMATIC S7-300 PS307 |
SIMATIC S7-300 PS307 |
| Output Voltage |
DC 24V |
DC 24V |
| Output Current |
5A |
5A |
| Input Voltage |
120/230V AC (auto-ranging) |
120/230V AC (auto-ranging) |
| Mounting |
35mm DIN Rail (S7-300 rack) |
35mm DIN Rail (S7-300 rack) |
| Backplane Interface |
S7-300 bus connector |
S7-300 bus connector (direct fit) |
| Terminal Block Wiring |
Standard screw terminals |
Identical terminal layout — no re-wiring required |
| Communication Protocol |
N/A (power supply) |
N/A — powers MPI/PROFIBUS/PROFINET CPU modules |
| Physical Dimensions |
80 × 125 × 120 mm |
80 × 125 × 120 mm (identical footprint) |
| Installation Space |
Slot 1 of S7-300 rack |
Slot 1 of S7-300 rack (no modification needed) |
| Replacement Complexity |
— |
Direct swap; no programming changes required |
| Warranty |
OEM (expired on legacy units) |
12-Month Warranty from TOPNLMS |
Seamless Upgrade Solutions: Migration-Ready Components for S7-300 Modernization
A successful S7-300 power supply replacement rarely occurs in isolation. In most retrofit scenarios, the PS307 5A module works in concert with a broader set of components that must be evaluated for compatibility before the system is returned to service. When migrating from an older S7-300 rack configuration, engineers typically assess the CPU module — such as the CPU 314C-2 DP or CPU 315-2 PN/DP — to confirm that firmware versions remain compatible with the existing STEP 7 project. The CPU communicates with field devices via PROFIBUS DP or PROFINET, and the integrity of that communication chain depends on a stable, regulated 24V supply delivered by the PS307 unit.
Beyond the CPU, the S7-300 rack commonly houses digital input modules (SM 321 series) and digital output modules (SM 322 series), both of which draw their logic supply voltage directly from the backplane bus powered by the PS307. Analog input modules such as the SM 331 and analog output modules such as the SM 332 are similarly dependent on clean DC power for accurate signal conversion. A degraded or undersized power supply is a frequent root cause of intermittent analog measurement drift and spurious digital output faults — issues that are immediately resolved by installing a correctly rated replacement PS307 unit.
For installations that include PROFIBUS DP communication, the CP 342-5 communications processor module may also be present in the rack. This module handles peer-to-peer data exchange with distributed I/O stations, variable-speed drives, and remote HMI panels. Ensuring the PS307 replacement delivers stable 24V output is critical to maintaining the DP cycle time and preventing bus timeout faults on the CP 342-5. Similarly, if the control cabinet includes an ET 200M distributed I/O station connected via PROFIBUS, the IM 153-2 interface module at that station must receive uninterrupted power from its own dedicated supply — a consideration that often surfaces during cabinet-level power audits triggered by a PS307 failure event.
In modernization projects where the S7-300 platform is being partially upgraded rather than fully replaced, engineers frequently retain the existing S7-300 rack and CPU while upgrading peripheral components. The TP700 Comfort or TP900 Comfort HMI panels, connected via PROFINET or MPI, continue to operate without reconfiguration when the PS307 is swapped. Programming cables such as the PC Adapter USB A2 remain compatible with the existing STEP 7 or TIA Portal project, allowing engineers to perform online diagnostics and force table verification immediately after the replacement without modifying the control program.
For facilities planning a longer-term migration toward the S7-1500 platform, the 3ES7307-1EA01-0AA0 serves as a cost-effective bridge solution that extends the operational life of the existing S7-300 installation while the migration project is scoped and budgeted. Signal isolators and terminal multiplier modules installed in the same cabinet can be retained without modification, as the 24V output specification is identical across both generations of SIEMENS power supply hardware.
Retrofit Guidance FAQ
Q: Do I need to modify the existing wiring when replacing the PS307 5A module?
A: No. The 3ES7307-1EA01-0AA0 uses an identical terminal block layout to the original PS307 unit. AC input connections (L1, N, PE) and DC output connections (M, L+) map directly to the same terminal positions. No re-termination is required.
Q: Will the replacement affect my STEP 7 or TIA Portal program?
A: No. The PS307 is a power supply module and does not participate in the PLC program logic. Replacing it does not alter the CPU memory, program blocks, data blocks, or hardware configuration stored in the CPU. The system resumes normal operation immediately after power-up.
Q: Is this module compatible with both PROFIBUS DP and PROFINET CPU variants?
A: Yes. The PS307 5A supplies backplane power to all S7-300 CPU variants regardless of communication protocol — including MPI-only CPUs, PROFIBUS DP CPUs, and PROFINET CPUs. Protocol selection is determined by the CPU module, not the power supply.
Q: Does the replacement fit in the same physical slot and cabinet space?
A: Yes. The 3ES7307-1EA01-0AA0 has an identical physical footprint (80 × 125 × 120 mm) and mounts in Slot 1 of the standard S7-300 rack. No cabinet modifications, additional mounting hardware, or spacer plates are required.
Q: What if my original unit was a 10A PS307 — can I use this 5A replacement?
A: Only if your total rack load does not exceed 5A. Before substituting a lower-rated supply, calculate the aggregate current draw of all installed modules. If the load exceeds 5A, the 10A variant (6ES7307-1KA02-0AA0) should be specified instead. Contact our technical team for a load calculation review.
Q: How long does commissioning take after installation?
A: Typical field replacement time is 20–30 minutes including power-down, module swap, wiring verification, and power-up. No special tools or software are required. The CPU performs a self-diagnostic on power-up and resumes the last saved program state automatically.
Warranty Assurance
Every 3ES7307-1EA01-0AA0 unit shipped by TOPNLMS is covered by a 12-Month Warranty from the date of delivery. Prior to dispatch, each unit undergoes a pre-shipment functional test verifying output voltage regulation (24V ±1%), output current capacity (5A continuous), input voltage switching (120V / 230V auto-range), and thermal protection response. Test records are retained and available upon request for quality audit purposes.
In the event of a warranty claim, TOPNLMS provides a replacement unit or full refund within the warranty period. Our after-sales response target is 24 hours for initial fault assessment and 72 hours for replacement dispatch. Units are shipped with ESD-protective packaging and include a certificate of inspection. Expedited shipping options are available for emergency breakdown situations to minimize production downtime.
For procurement teams requiring documentation, we can provide a proforma invoice, packing list, and country-of-origin certificate (Germany) to support import clearance and internal purchasing approval workflows. Bulk orders of 5 units or more qualify for priority allocation from our bonded warehouse stock in Xiamen, China.