PILZ 777080 PNOZ X11P Original Industrial Spare X Series Compatible
777080 PNOZ X11PBuy PILZ 777080 PNOZ X11P original safety relay. 6-output dual-channel, 24VDC, SIL3 PLe. X Series compatible industrial spare. 12-month warranty. Fast shipping.
Request availability, condition, lead time and export shipping details for 774086 PNOZ 11.
Send this exact part number, quantity and destination country. TOPNLMS will confirm availability, condition and export lead time before quotation.
The PILZ 774086 PNOZ 11 is a dual-channel safety relay designed for emergency stop (E-Stop) and guard door monitoring applications within the PNOZ Classic Series platform. For facilities operating legacy safety circuits built around PNOZ Classic modules, this unit provides a direct, validated replacement path that preserves existing wiring topology, DIN rail footprint, and 24 V DC supply architecture — minimizing engineering rework and unplanned downtime during modernization projects.
Industrial sites running aging safety relay panels often face the challenge of sourcing discontinued or end-of-life PNOZ Classic modules. The PILZ 774086 PNOZ 11 addresses this directly: it maintains the same terminal assignment as earlier PNOZ Classic variants, allowing field technicians to swap the module without rewiring the safety loop. The dual-channel input architecture supports Category 3 and Category 4 safety functions per ISO 13849-1, making it suitable for press lines, robotic cells, conveyor systems, and packaging machinery where guard door interlocks and E-Stop circuits must meet PLd or PLe requirements.
When migrating from older PNOZ 1, PNOZ 2, or PNOZ 5 modules, engineers will find that the 774086 PNOZ 11 retains the familiar screw-terminal layout and 22.5 mm housing width. This means existing control cabinet designs — including those using PILZ PDP67 distributed safety I/O or PILZ PSS 4000 safety controllers — can integrate the replacement module without cabinet redesign. The module’s output relay contacts are rated for direct switching of safety-rated contactors and motor starters, preserving compatibility with downstream power switching devices already installed in the panel.
For sites transitioning from hardwired safety relay panels toward networked safety architectures, the PNOZ 11 can serve as an interim solution while the broader migration to PILZ PNOZmulti 2 configurable safety relay systems or PILZ PSS 4000 safety PLC platforms is planned and executed. During this transition period, the PNOZ 11 continues to protect the machine while engineering teams validate the new safety program logic and commission the replacement safety controller.
Communication protocol compatibility is straightforward: the PNOZ 11 operates as a standalone hardwired device and does not require fieldbus configuration, making it immediately compatible with existing Profibus DP, Profinet, or DeviceNet safety network segments without gateway changes. Where the broader safety system includes PILZ PDP67 F I/O modules or PILZ PNOZ m B0 base units, the PNOZ 11 can be wired in parallel to provide local E-Stop monitoring while the network-based safety logic handles zone-level interlocking.
Physical installation follows standard PNOZ Classic mounting procedures: 35 mm DIN rail, 24 V DC supply via terminals A1/A2, and safety input channels via S11/S12 and S21/S22. The module’s LED diagnostics provide immediate feedback on channel status, cross-fault detection, and output relay state — reducing commissioning time during retrofit projects. For sites using PILZ PSEN safety switches or PILZ PSENcode coded magnetic switches on guard doors, the PNOZ 11’s input circuit is fully compatible with these sensor types without additional signal conditioning.
Procurement teams evaluating this replacement should note that the 774086 PNOZ 11 is stocked and available for immediate dispatch. Each unit undergoes functional testing prior to shipment, covering input channel response time, output relay switching, and cross-fault detection. A 12-month warranty is included, covering manufacturing defects and functional failures under normal operating conditions. Units are shipped with original PILZ documentation where available, supporting CE marking compliance records and machinery safety file updates.
| Parameter | Legacy PNOZ Classic (PNOZ 1 / PNOZ 5) | PILZ 774086 PNOZ 11 (Replacement) |
|---|---|---|
| Supply Voltage | 24 V DC | 24 V DC (identical) |
| Input Channels | Dual-channel (S11/S12, S21/S22) | Dual-channel (S11/S12, S21/S22) — same terminal layout |
| Housing Width | 22.5 mm | 22.5 mm — no cabinet redesign required |
| DIN Rail Mounting | 35 mm | 35 mm — direct drop-in |
| Safety Category | Cat. 3 / Cat. 4 (ISO 13849-1) | Cat. 3 / Cat. 4 — PLd/PLe compliant |
| Output Contacts | 2 NO safety outputs | 2 NO safety outputs — direct contactor switching |
| Cross-Fault Detection | Yes | Yes — maintained |
| Rewiring Required | — | No — terminal-compatible replacement |
| Communication | Hardwired only | Hardwired only — no fieldbus reconfiguration |
| Warranty | — | 12-Month Warranty included |
A complete PNOZ Classic panel retrofit typically involves more than a single module swap. Alongside the PILZ 774086 PNOZ 11, migration projects commonly require PILZ PSEN 1.1p safety switches for guard door monitoring, PILZ PSENcode coded magnetic switches for high-category interlocking, and PILZ PDP67 F distributed I/O modules where the safety architecture is being extended to remote machine zones. For sites upgrading the safety controller layer, PILZ PNOZmulti 2 configurable safety relay units — such as the PNOZ m B0 base unit paired with PNOZ mi1p I/O expansion modules — provide a scalable path beyond hardwired relay logic. Power supply integrity is critical during retrofit: PILZ PMD safety power supplies ensure stable 24 V DC delivery to the safety relay bus. Where signal isolation between legacy analog I/O and new safety circuits is required, DIN rail signal isolators and PILZ PNOZ X series auxiliary relays are commonly used to bridge the interface. Programming and diagnostic access during commissioning is supported via PILZ PNOZmulti Configurator software, which does not require hardware changes to the PNOZ 11 itself but is essential for validating the broader safety system after module replacement.
Q: Can I replace a PNOZ 1 or PNOZ 5 with the 774086 PNOZ 11 without rewiring?
A: Yes. The PNOZ 11 uses the same terminal designations (A1, A2, S11, S12, S21, S22, 13/14, 23/24) as earlier PNOZ Classic modules. In most installations, the replacement is a direct swap with no wiring changes required.
Q: Is the PNOZ 11 compatible with my existing Profinet or Profibus safety network?
A: The PNOZ 11 is a hardwired device and does not connect to fieldbus networks directly. It operates independently of your Profinet or Profibus segment, so no network reconfiguration is needed. If your system uses PILZ PDP67 F I/O for network-based safety, the PNOZ 11 can be wired in parallel for local E-Stop monitoring.
Q: What safety category does the PNOZ 11 support?
A: The module supports Category 3 and Category 4 per ISO 13849-1, achieving Performance Level d (PLd) or PLe depending on the application architecture and MTTFd values of connected sensors.
Q: Will the PNOZ 11 fit in my existing control cabinet without modification?
A: Yes. The 22.5 mm housing width and 35 mm DIN rail mounting are identical to earlier PNOZ Classic modules. No cabinet cutouts, additional mounting hardware, or busbar changes are required.
Q: How do I validate the replacement during commissioning?
A: After installation, perform a functional test of each safety input channel independently, verify cross-fault detection by introducing a deliberate short between channels, and confirm output relay switching under load. PILZ’s standard PNOZ Classic commissioning checklist applies without modification.
Every PILZ 774086 PNOZ 11 unit supplied by TOPNLMS is covered by a 12-month warranty from the date of shipment. Prior to dispatch, each module undergoes functional verification covering supply voltage response, dual-channel input switching, cross-fault detection, and output relay operation. Units that do not pass functional testing are not shipped.
In the event of a warranty claim, TOPNLMS provides replacement unit dispatch or full refund processing within agreed lead times. Our after-sales response team is reachable via email and phone for technical support during installation and commissioning. All units are shipped with appropriate protective packaging to prevent ESD damage and mechanical stress in transit.
For procurement teams requiring documentation, test reports or certificates of conformity can be provided upon request to support your machinery safety file and CE marking records.
Click Quote This Model and the Part Number field will auto-fill with 774086 PNOZ 11.