PHOENIX DIGITAL OCX-CTN-85-R-D-ST-24V Ruggedized Fiber Optic
OCX-CTN-85-R-D-ST-24VPHOENIX DIGITAL OCX-CTN-85-R-D-ST-24V ruggedized multimode fiber optic converter, 24VDC ST duplex. EMI-immune, DIN rail, 12-month warranty. In stock.
Request availability, condition, lead time and export shipping details for OCX-CTN-13-R-D-ST-ACV.
Send this exact part number, quantity and destination country. TOPNLMS will confirm availability, condition and export lead time before quotation.
In modern industrial automation environments, the reliability of fiber optic communication infrastructure is non-negotiable. The PHOENIX DIGITAL OCX-CTN-13-R-D-ST-ACV is an original fiber optic communication module from the OCX-CTN series, engineered for high-integrity data transmission in demanding industrial control systems. Whether deployed in a PLC-based production line, a DCS-controlled process plant, or a distributed I/O network, this module serves as a critical link in the communication backbone — and its availability as a verified spare part is a cornerstone of any serious maintenance strategy.
Sourced directly from authorized supply channels, this unit is tested, inspected, and shipped with a 12-month quality warranty, giving maintenance engineers and procurement teams the confidence to stock it as a long-term asset rather than a reactive purchase.
| Parameter | Specification |
|---|---|
| Part Number | OCX-CTN-13-R-D-ST-ACV |
| Brand | PHOENIX DIGITAL |
| Series | OCX-CTN |
| Module Type | Fiber Optic Communication Module |
| Connector Type | ST (Straight Tip) Fiber Connector |
| Signal Mode | Digital / ACV (AC Voltage Compatible) |
| Transmission Medium | Fiber Optic (Single-mode / Multi-mode compatible per installation) |
| Country of Origin | Germany (DE) |
| Operating Environment | Industrial — suitable for EMI-intensive, high-vibration environments |
| Installation | DIN rail or panel-mount per system configuration |
| Compatibility | OCX-CTN series; compatible with PHOENIX DIGITAL fiber optic ring and star topologies |
| Weight | 1,110 g |
| Warranty | 12 Months — tested and verified prior to shipment |
Fiber optic communication modules like the OCX-CTN-13-R-D-ST-ACV are often overlooked during routine maintenance cycles — until a communication fault triggers an unplanned shutdown. A proactive maintenance approach treats this module as a scheduled inspection item, not just a reactive replacement part.
During planned downtime or annual control cabinet inspections, maintenance teams should verify the integrity of the ST fiber connectors, check for signal attenuation caused by contaminated or bent fiber cables, and confirm that the module’s LED status indicators are functioning within normal parameters. At the same time, it is advisable to inspect the OCX-CTN-13-R-D-ST base variant and any adjacent OCX-CTN fiber optic repeater modules in the same ring topology, as a degraded node upstream can mask faults in the target module during diagnostics.
In the same control cabinet, engineers should also assess the condition of the PHOENIX DIGITAL power supply modules feeding the communication rack — voltage instability is a leading cause of premature fiber module failure. Paired inspection of terminal blocks and DIN rail bus connectors ensures that the module’s power and signal interfaces remain mechanically secure. If the system includes PHOENIX DIGITAL signal conditioners or isolation amplifiers, these should be tested concurrently, as signal integrity issues in the analog layer can propagate into the digital communication stack.
For facilities running mixed PLC/DCS architectures, the OCX-CTN-13-R-D-ST-ACV often interfaces with remote I/O modules and fieldbus gateway modules — both of which should be included in the same maintenance window. Stocking a spare fiber optic patch cable (ST-ST, appropriate wavelength) alongside this module is strongly recommended, as cable degradation is frequently misdiagnosed as module failure, leading to unnecessary replacements. Similarly, surge protection modules installed at the cabinet entry point protect the entire communication chain, including this module, from transient voltage events.
Facilities managing aging PHOENIX DIGITAL fiber optic networks should also evaluate the status of any OCX-CTN media converters in the system. These components share the same operational lifecycle as the OCX-CTN-13-R-D-ST-ACV and are prime candidates for simultaneous replacement during major overhauls, reducing the risk of a secondary failure shortly after the primary repair.
The OCX-CTN-13-R-D-ST-ACV is a direct original replacement for aging or failed units within the OCX-CTN product family. Unlike generic third-party alternatives, this original module maintains full compatibility with existing PHOENIX DIGITAL fiber optic network configurations — no firmware adjustments, no topology reconfiguration, and no re-commissioning of adjacent nodes.
For facilities operating legacy systems where the original module is no longer available through standard distribution channels, sourcing a verified original spare from a specialist industrial parts supplier is the most reliable path to restoring system integrity. Substituting with an incompatible module — even one with similar electrical specifications — risks introducing latency, packet loss, or complete communication failure in ring-topology networks where every node must meet the same timing and signal standards.
Stocking one or two units of the OCX-CTN-13-R-D-ST-ACV as on-site inventory eliminates the lead time risk associated with emergency procurement. In high-availability production environments, the cost of a single hour of unplanned downtime typically exceeds the cost of maintaining a small buffer stock of critical communication spares by a significant margin. This module’s compact form factor and stable shelf life make it an ideal candidate for long-term spare parts inventory programs.
For system integrators managing multiple sites, consolidating OCX-CTN series spares — including the OCX-CTN-13-R-D-ST-ACV and related variants — into a centralized spare parts pool reduces per-site inventory costs while maintaining rapid deployment capability across the network.
Q1: Is the OCX-CTN-13-R-D-ST-ACV an original PHOENIX DIGITAL module or a compatible replacement?
A: This is an original PHOENIX DIGITAL module, not a third-party compatible. It is sourced from verified supply channels and carries the original manufacturer’s specifications, ensuring full compatibility with existing OCX-CTN series installations.
Q2: What testing is performed before shipment, and what does the 12-month warranty cover?
A: Each unit undergoes functional verification and visual inspection prior to dispatch. The 12-month warranty covers manufacturing defects and functional failures under normal operating conditions. Units that fail within the warranty period are eligible for replacement or refund subject to inspection.
Q3: How do I verify compatibility with my existing fiber optic network before installation?
A: Confirm that your existing network uses ST-type fiber connectors and that the topology (ring or star) matches the OCX-CTN-13-R-D-ST-ACV’s supported configurations. Cross-reference the module’s ACV designation with your system’s signal voltage requirements. If in doubt, contact our technical team with your system’s network diagram for pre-purchase compatibility verification.
Q4: What is the recommended spare parts lifecycle strategy for this module?
A: For critical production environments, we recommend maintaining at least one on-site spare unit per fiber optic ring segment. Modules in continuous operation should be scheduled for inspection every 24–36 months, with replacement triggered by signal degradation, connector wear, or LED fault indicators. Procurement lead times for original OCX-CTN series modules can vary; maintaining buffer stock eliminates emergency sourcing risk.
Click Quote This Model and the Part Number field will auto-fill with OCX-CTN-13-R-D-ST-ACV.