Language English USD Currency
Call WhatsApp RFQ
PFEIFFER VACUUM Industrial Automation Part

PFEIFFER PKR 251 Original Industrial Spare PKR Compatible

Request availability, condition, lead time and export shipping details for D-35614 PKR 251.

PFEIFFER VACUUM

D-35614 PKR 251

Send this exact part number, quantity and destination country. TOPNLMS will confirm availability, condition and export lead time before quotation.

Part NumberD-35614 PKR 251
ConditionAvailability Check
Lead TimeRFQ Confirmation
SeriesOther series
ShippingExport packing available
Model checked before quotation Condition and packing confirmed Fast RFQ response by sales engineer

Product Overview

PFEIFFER PKR 251 Original Industrial Spare PKR Compatible: System Stability and Industrial Spare Maintenance Value

The PFEIFFER PKR 251 (D-35614) is a compact full-range vacuum gauge engineered for demanding industrial environments where measurement accuracy and system uptime are non-negotiable. As an original PFEIFFER VACUUM spare part from the PKR Series, this gauge delivers reliable pressure measurement across a wide range — from atmospheric pressure down to ultra-high vacuum — making it an essential component in semiconductor fabrication, coating systems, research laboratories, leak detection equipment, and general industrial vacuum processes.

Maintaining a healthy vacuum system requires more than reactive repair. Facilities that operate PFEIFFER turbomolecular pumps, rotary vane pumps, or dry vacuum pumps understand that a failed or drifted vacuum gauge can cascade into unplanned downtime, product loss, and costly emergency procurement. Stocking the PKR 251 as a verified spare ensures your maintenance team can execute a rapid, like-for-like replacement without waiting on extended lead times or risking compatibility issues with non-original substitutes.

Critical Technical Specs Table

Parameter Specification
Model PKR 251
Part Number / SKU D-35614 PKR 251
Brand PFEIFFER VACUUM
Series PKR Series (Compact Full Range)
Measurement Principle Pirani + Cold Cathode (Combined)
Measurement Range 5×10⁻⁹ to 1,000 hPa (mbar)
Output Signal Analog voltage output (0–10 V logarithmic)
Supply Voltage 24 VDC (±10%)
Power Consumption ≤ 5 W (typical)
Process Connection DN 25 ISO-KF flange
Housing Material Stainless steel / aluminium alloy
Operating Temperature 10°C to 50°C
Storage Temperature -20°C to 70°C
Protection Class IP 40
Country of Origin Germany (DE)
Compatibility PFEIFFER TPG 261, TPG 262, DCU 200, MaxiGauge controllers; PKR Series gauge heads
Application Semiconductor, coating, R&D, leak detection, industrial vacuum systems
Warranty 12 Months from date of shipment
Pre-shipment Testing Functionally tested before dispatch

Preventive Maintenance Strategy

A structured preventive maintenance (PM) program for vacuum systems built around PFEIFFER equipment should treat the PKR 251 not as a consumable, but as a precision instrument with a defined service interval. In practice, maintenance engineers performing scheduled shutdowns on turbomolecular pump stations — such as those using the PFEIFFER TMH 071 P or TMU 261 turbopumps — should simultaneously inspect the PKR 251 for zero-point drift, contamination of the cold cathode electrode, and integrity of the KF flange seal. A drifted gauge that reads falsely low can mask a deteriorating pump performance, leading to process failures that are far more expensive than the gauge itself.

During control cabinet inspections, it is equally important to verify the condition of the PFEIFFER TPG 262 dual-channel gauge controller that typically drives the PKR 251 signal. Loose connector pins, oxidized contacts on the Sub-D interface, or firmware mismatches between the controller and gauge head are common root causes of erratic readings in aging vacuum systems. Pairing a PKR 251 replacement with a simultaneous check of the PFEIFFER DCU 200 display and control unit ensures the entire measurement chain is validated in a single maintenance window.

For facilities running multi-stage vacuum systems, the backing line components deserve equal attention. The PFEIFFER DUO 5 M rotary vane pump and its associated oil mist filter (PK 001 330-T) should be inspected for oil level, contamination, and exhaust filter saturation whenever the PKR 251 is serviced. A degraded backing pump elevates the foreline pressure, which directly stresses the cold cathode section of the PKR 251 and shortens its service life. Similarly, the PFEIFFER EVN 116 SA solenoid valve used for venting control should be cycled and tested for response time during the same PM visit — a slow or stuck vent valve creates pressure spikes that can damage the gauge electrode.

In semiconductor and thin-film coating environments, the PFEIFFER PKR 360 (a higher-specification full-range gauge from the same PKR family) is sometimes used in parallel with the PKR 251 for cross-validation of chamber pressure. Maintaining a spare PKR 360 alongside the PKR 251 in your critical spares inventory provides redundancy for both measurement ranges and ensures that a single gauge failure does not halt production. Additionally, the PFEIFFER IKR 270 cold cathode gauge is commonly found in the same vacuum systems for ultra-high vacuum measurement below the PKR 251’s lower range limit — inspecting both gauges during the same shutdown maximizes maintenance efficiency.

Do not overlook the KF 25 centering rings and O-rings at the gauge flange connection. These elastomer seals are a frequent source of virtual leaks in aging systems and should be replaced as a matter of course whenever the PKR 251 is removed for inspection or replacement. Keeping a stock of PFEIFFER-compatible KF 25 and KF 40 sealing sets alongside the PKR 251 spare ensures your team can complete the replacement without a secondary parts order.

Strategic Replacement Solutions

The PKR 251 (D-35614) is a direct original replacement for aging or failed PKR Series gauge heads installed in PFEIFFER vacuum systems manufactured from the early 2000s onward. Unlike third-party alternatives that may offer only partial measurement range coverage or incompatible analog output scaling, the original PKR 251 maintains full compatibility with PFEIFFER TPG 261, TPG 262, and MaxiGauge multi-channel controllers without requiring recalibration of the controller’s gauge type settings.

For facilities managing legacy systems where the original PKR 251 has been in service for five or more years, proactive replacement — rather than waiting for failure — is the recommended strategy. The cold cathode section of a full-range gauge is susceptible to contamination from process gases, pump oil backstreaming, and particulate deposition. A gauge that appears functional may already exhibit measurement errors of half a decade or more in the mid-vacuum range, silently compromising process quality. Replacing the PKR 251 on a scheduled basis (typically every 3–5 years depending on process cleanliness) eliminates this hidden risk and restores measurement traceability.

From a procurement standpoint, sourcing the PKR 251 through TOPNLMS provides access to verified original stock with full traceability, pre-shipment functional testing, and a 12-month warranty — eliminating the uncertainty associated with grey-market or refurbished units. Our inventory is maintained to support rapid dispatch, minimizing the gap between order placement and return-to-service for your vacuum system.

Support FAQ

Q1: Is the PKR 251 (D-35614) compatible with my existing PFEIFFER gauge controller?
A: Yes. The PKR 251 is designed for direct compatibility with PFEIFFER TPG 261, TPG 262, DCU 200, and MaxiGauge controllers. The analog output (0–10 V logarithmic) and connector pinout are standardized across the PKR Series. No controller reconfiguration is required for a like-for-like replacement.

Q2: What pre-shipment testing is performed on the PKR 251?
A: Every PKR 251 unit dispatched from TOPNLMS undergoes functional verification prior to shipment, including power-on testing and output signal validation. Units are packaged in anti-static, shock-protected packaging to prevent transit damage. A 12-month warranty is provided from the date of shipment.

Q3: How do I determine if my PKR 251 needs replacement versus recalibration?
A: If the gauge exhibits persistent zero-point offset at atmospheric pressure, erratic readings in the mid-vacuum range (10⁻³ to 10⁻¹ hPa), or failure to ignite the cold cathode below 10⁻² hPa, replacement is typically more cost-effective than field recalibration. Contaminated electrodes cannot be reliably cleaned in the field. Contact our technical team at [email protected] for diagnostic guidance.

Q4: What is the recommended spare inventory strategy for the PKR 251?
A: For facilities with two or more vacuum systems using PKR Series gauges, we recommend maintaining a minimum of one PKR 251 spare per system cluster. Given the gauge’s role as a critical measurement point for process control and pump protection, a stockout during an unplanned failure can result in extended downtime. Bulk procurement of 2–5 units qualifies for volume pricing — contact us for a quotation.


© 2026 TOPNLMS. All rights reserved.
Original Source: https://topnlms.com
Contact: [email protected] | +86 18359293191

Quick Inquiry

Click Quote This Model and the Part Number field will auto-fill with D-35614 PKR 251.