PEACOCK C-5 VER.3 Replacement/Upgrade Solution for C-5 Series
C-5 VER.3PEACOCK C-5 VER.3 drop-in replacement for C-5 Series digital counters. Compatible wiring, DIN rail mount, 12-month warranty. Ready to ship from Xiamen.
Request availability, condition, lead time and export shipping details for COM5V2.
Send this exact part number, quantity and destination country. TOPNLMS will confirm availability, condition and export lead time before quotation.
In high-precision manufacturing environments, dimensional gauging systems are the backbone of quality assurance. The PEACOCK COM5V2 digital comparator — part of the trusted COM5 Series — is an original spare component engineered for long-term reliability in industrial metrology applications. Whether you are managing a scheduled overhaul, responding to an unplanned instrument failure, or building a strategic spare parts inventory, the COM5V2 delivers the measurement accuracy and system compatibility your production line demands.
PEACOCK (Ozaki Mfg. Co., Ltd.) has been a cornerstone of Japanese precision instrumentation for decades. The COM5 Series digital comparators are widely deployed in automotive component inspection, aerospace part verification, bearing manufacturing, and general machined-part QC lines. Sourcing an original COM5V2 replacement unit ensures your gauging station returns to full specification without recalibration drift or compatibility compromises introduced by non-original substitutes.
| Parameter | Specification |
|---|---|
| Model / SKU | COM5V2 |
| Series | COM5 Series |
| Brand / Manufacturer | PEACOCK (Ozaki Mfg. Co., Ltd.) |
| Product Type | Digital Comparator |
| Country of Origin | Japan |
| Display Type | Digital LCD / LED readout (series standard) |
| Measurement Function | Dimensional comparison, tolerance pass/fail indication |
| Output Interface | Compatible with COM5 Series gauge amplifier / controller inputs |
| Application Environment | Industrial metrology, QC inspection stations, machined-part gauging |
| Mounting / Installation | Standard COM5 Series gauge stand and fixture compatible |
| Operating Temperature | 0°C – 40°C (typical industrial metrology environment) |
| Weight | 1,340 g (unit with standard accessories) |
| Compatibility | Direct replacement for COM5 Series comparator stations |
| Condition | Original, tested before shipment |
| Warranty | 12 Months from date of shipment |
A digital comparator failure rarely occurs in isolation. In a typical QC gauging station, the COM5V2 operates as part of an integrated measurement chain. When scheduling a replacement or conducting a planned shutdown inspection, maintenance engineers should treat the COM5V2 swap as an opportunity to audit the entire gauging circuit for wear, drift, or impending failure.
Begin by inspecting the gauge probe and contact tip — the mechanical interface between the workpiece and the comparator. Worn or contaminated contact tips introduce systematic measurement error that persists even after a new COM5V2 is installed. Alongside the comparator, verify the condition of the gauge amplifier unit (the signal conditioning module that drives the COM5V2 display), as amplifier drift is a common root cause of apparent comparator malfunction.
Check the gauge stand and fixture clamps for mechanical play. Loose fixturing causes repeatability failures that are frequently misdiagnosed as comparator faults. If your station uses a PEACOCK gauge multiplexer or selector switch to route signals from multiple probes to a single COM5 Series display, inspect the selector contacts for oxidation — a common failure mode in humid factory environments.
For stations integrated into automated inspection lines, review the BCD or analog output cable assemblies connecting the COM5V2 to your SPC data collection system or PLC input module. Cable insulation fatigue and connector pin corrosion are leading causes of intermittent data dropouts. While the comparator is offline for replacement, this is the ideal window to swap in fresh shielded signal cables and verify connector seating.
If your facility operates multiple COM5 Series stations, consider maintaining a calibrated reference gauge block set on-site. Immediate post-installation verification against a traceable reference shortens the return-to-production timeline from hours to minutes. Pair this practice with a spare COM5 Series probe set in your storeroom — probes are consumable items with a finite contact-tip lifespan, and having spares on hand eliminates the most common cause of unplanned gauging downtime.
For facilities running legacy PEACOCK COM3 or COM5 Series gauge controllers alongside newer digital systems, a signal isolator or converter module may be present in the circuit. Inspect isolator output voltage levels during the maintenance window, as isolator degradation can cause the replacement COM5V2 to display erratic readings immediately after installation — a failure mode that is easily misattributed to a defective new unit.
Finally, review your power supply rail feeding the gauging station. Voltage sag or ripple on the instrument supply bus is a known cause of premature digital comparator failure. A bench power supply check during the maintenance window, or installation of a dedicated instrument-grade power conditioner, significantly extends the service life of the replacement COM5V2 and the surrounding measurement system.
The PEACOCK COM5V2 is a direct original replacement for aging COM5 Series comparator units. Many manufacturing facilities continue to operate COM5 Series gauging stations that were installed in the 1990s and 2000s — a testament to the platform’s durability. However, as original units age, sourcing genuine replacement parts becomes the critical factor in sustaining system uptime.
Substituting the COM5V2 with a non-original or incompatible comparator introduces calibration uncertainty, requires fixture modification, and may invalidate existing measurement system analysis (MSA) records — a significant compliance risk in IATF 16949 or ISO 9001 certified facilities. By sourcing an original COM5V2, maintenance teams preserve the existing gauge R&R baseline, avoid re-qualification costs, and return the station to production with confidence.
For facilities managing end-of-life COM5 Series infrastructure, a strategic approach is to purchase two COM5V2 units simultaneously: one for immediate installation and one as a cold standby spare. This eliminates the lead-time risk associated with future failures and is particularly valuable for production lines where gauging downtime directly gates shipment schedules.
All COM5V2 units shipped from TOPNLMS are tested prior to dispatch, clearly labeled with the original PEACOCK part identification, and covered by a 12-month warranty from the date of shipment. Expedited shipping options are available for urgent maintenance situations.
Q1: Is the COM5V2 a direct drop-in replacement for my existing COM5 Series comparator?
Yes. The COM5V2 is an original PEACOCK COM5 Series unit and is designed as a direct replacement for other COM5 Series digital comparators. No fixture modification or reconfiguration of the gauge amplifier is required in standard COM5 Series installations. We recommend verifying your specific station model against the COM5V2 datasheet if your installation includes non-standard signal routing.
Q2: What does the 12-month warranty cover, and what is the claims process?
The 12-month warranty covers manufacturing defects and functional failures under normal operating conditions from the date of shipment. It does not cover damage resulting from incorrect installation, electrical overstress, or physical impact. To initiate a warranty claim, contact us at [email protected] with your order reference and a description of the fault. We will arrange inspection and replacement or repair as appropriate.
Q3: How is the COM5V2 tested before shipment?
Each COM5V2 unit undergoes functional verification prior to dispatch. Testing confirms display operation, output signal integrity, and basic dimensional response. Units that do not pass functional verification are not shipped. A test confirmation is included with the shipment documentation.
Q4: What is the recommended spare parts stocking strategy for COM5 Series gauging stations?
For facilities with two or more COM5 Series stations, we recommend maintaining at least one COM5V2 unit as a cold standby spare. For high-throughput lines where gauging downtime directly impacts production output, a ratio of one spare per three active stations is a practical starting point. Combine the COM5V2 spare with a set of replacement contact tips and a spare gauge cable assembly to cover the most common failure modes without overstocking.
Click Quote This Model and the Part Number field will auto-fill with COM5V2.