EPRO PR6423/001-010-CN CON021 Replacement for PR6423 Series
PR6423/001-010-CN CON021EPRO PR6423/001-010-CN CON021 proximity probe replacement. Compatible upgrade for PR6423 Series. Eddy current, 12-month warranty, fast global shipping.
Request availability, condition, lead time and export shipping details for NA2-N16D.
Send this exact part number, quantity and destination country. TOPNLMS will confirm availability, condition and export lead time before quotation.
The Panasonic NA2-N16D is a high-integrity, 16-beam Type 4 OSSD dual-channel safety light curtain engineered for demanding industrial environments where personnel protection and machine safety cannot be compromised. Designed to IEC 61496-1/-2 and ISO 13849-1 standards, the NA2-N16D delivers reliable presence-sensing performance in conditions characterized by high ambient vibration, electromagnetic interference (EMI), airborne particulates, and wide temperature fluctuations — precisely the conditions found in automotive assembly lines, stamping presses, robotic work cells, and heavy manufacturing facilities.
As part of Panasonic’s proven NA2 Series safety light curtain family, the NA2-N16D integrates seamlessly into safety-rated control architectures. Its dual-channel OSSD (Output Signal Switching Device) outputs connect directly to safety relays such as the Panasonic SF-C11 safety relay module or third-party equivalents, enabling PLd/Cat.3 or PLe/Cat.4 safety loops depending on system configuration. When paired with a Siemens SIRIUS 3SK1 safety relay or a Pilz PNOZ X safety relay, the NA2-N16D forms a complete, certified safety circuit that satisfies the most stringent machinery directive requirements.
In PLC-integrated safety systems, the NA2-N16D’s OSSD signals feed directly into safety-rated digital input modules — for example, a Siemens ET 200SP F-DI safety input module or an Allen-Bradley 1734-IB8S POINT Guard I/O module — allowing the safety state to be monitored and logged within the main control program. This tight integration with distributed I/O architectures ensures that safety events are captured in real time, supporting both machine protection and regulatory audit trails.
The NA2-N16D’s rugged aluminum housing and IP65-rated enclosure make it suitable for deployment in environments where coolant mist, metal swarf, and hydraulic oil vapors are present. Its internal optical design minimizes false trips caused by reflective surfaces or ambient light interference — a critical advantage in facilities where overhead lighting, welding arcs, or high-intensity process lighting could otherwise compromise lesser sensors. The unit operates reliably across a supply voltage range of 24 V DC ±10%, compatible with standard Siemens SITOP PSU100S or Phoenix Contact QUINT-PS industrial power supplies commonly found in control cabinet installations.
For facilities operating continuous production lines — such as food and beverage processing, pharmaceutical packaging, or electronics manufacturing — the NA2-N16D supports muting functionality when used with compatible muting controllers, allowing material transport through the detection zone without triggering a safety stop. This capability, combined with the unit’s fast response time of ≤14 ms, ensures that production throughput is maintained while personnel safety is never sacrificed.
The NA2-N16D is also well-suited for integration into safety-rated communication networks. When the host PLC or safety controller supports PROFIsafe or CIP Safety protocols — such as a Siemens S7-1500F or an Allen-Bradley GuardLogix 5580 — the OSSD outputs can be wired to a compatible F-DI module or safety gateway, enabling full diagnostic transparency over the fieldbus. This eliminates the need for dedicated hardwired safety buses in many retrofit applications, reducing panel wiring complexity and commissioning time.
From a spare-parts and lifecycle management perspective, the NA2-N16D is a direct replacement for aging or end-of-life safety light curtains in existing Panasonic NA2 Series installations. Its backward-compatible mounting footprint and connector pinout simplify field replacement, minimizing downtime during scheduled maintenance windows. TOPNLMS maintains verified stock of the NA2-N16D and conducts pre-shipment functional testing — including OSSD output verification and beam alignment checks — before every unit leaves our facility.
| Parameter | Specification |
|---|---|
| Model / SKU | NA2-N16D |
| Brand / Series | Panasonic / NA2 Series |
| Product Type | Safety Light Curtain |
| Safety Category | Type 4 (IEC 61496-1/-2), PLe / Cat.4 capable |
| Number of Beams | 16 |
| Output Type | OSSD Dual-Channel (PNP, 24 V DC) |
| Response Time | ≤14 ms |
| Supply Voltage | 24 V DC ±10% |
| Protection Rating | IP65 |
| Operating Temperature | -10°C to +55°C |
| Vibration Resistance | 10–55 Hz, 1.5 mm amplitude (IEC 60068-2-6) |
| EMI Resistance | Compliant with IEC 61000-4 series |
| Housing Material | Anodized aluminum extrusion |
| Country of Origin | Japan |
| Applicable Standards | IEC 61496-1/-2, ISO 13849-1, EN 62061 |
| Compatible Safety Relays | Panasonic SF-C11, Siemens SIRIUS 3SK1, Pilz PNOZ X series |
| Compatible I/O Modules | Siemens ET 200SP F-DI, AB 1734-IB8S, Beckhoff EL1904 |
| Application Scenarios | Press brakes, robotic cells, conveyor access points, packaging lines |
| Warranty | 12 Months — covers manufacturing defects and functional failure |
| Pre-Shipment Testing | OSSD output verification, beam alignment, insulation check |
The NA2-N16D does not operate in isolation — it is one component in a layered safety and control architecture. In a typical press brake or stamping cell, the light curtain’s OSSD outputs connect to a Panasonic SF-C11 safety relay, which in turn controls the machine’s main contactor and brake circuit. The safety relay’s feedback loop monitors the contactor’s auxiliary contacts, ensuring that any welded or stuck contact is detected before the next machine cycle begins.
For larger installations managed by a Siemens S7-1500F safety PLC, the NA2-N16D integrates via a Siemens ET 200SP F-DI 8x24VDC HF safety input module, allowing the safety program to read the curtain’s state, log safety events, and trigger controlled shutdowns of associated drives — including Siemens SINAMICS G120 variable frequency drives equipped with Safe Torque Off (STO) functionality. This architecture is common in automotive body-in-white welding lines and heavy stamping operations.
In facilities using Rockwell Automation platforms, the NA2-N16D pairs with an Allen-Bradley GuardLogix 5580 safety controller and 1734-IB8S POINT Guard I/O modules to deliver an equivalent safety architecture under CIP Safety protocol. The curtain’s dual-channel OSSD outputs satisfy the redundancy requirements of SIL 2 / PLd safety loops without additional external components.
Power supply stability is equally critical. The NA2-N16D requires a clean, regulated 24 V DC supply; a Phoenix Contact QUINT-PS/1AC/24DC/10 or Siemens SITOP PSU100S 24V/10A power supply with integrated diagnostics ensures that voltage dips or transients — common near large motor starters or welding equipment — do not cause nuisance trips or, worse, undetected safety failures. Terminal connections within the control cabinet should be made using Phoenix Contact CLIPLINE complete or Weidmüller Klippon terminal blocks to maintain reliable, vibration-resistant wiring integrity over the equipment’s service life.
The Panasonic NA2-N16D finds its most demanding applications in critical infrastructure sectors where unplanned downtime carries severe operational and financial consequences.
In oil and gas processing facilities, the NA2-N16D protects personnel working near high-pressure valve actuators, compressor skids, and rotating equipment. Its IP65 rating and vibration-resistant construction allow it to function reliably in environments where mechanical vibration from reciprocating compressors and pipeline pressure surges are constant. The dual-channel OSSD architecture satisfies the functional safety requirements of IEC 61511 (Safety Instrumented Systems) when integrated into a certified safety instrumented function (SIF).
In mining and mineral processing, the NA2-N16D is deployed at conveyor transfer points, crusher access gates, and screening plant walkways. The unit’s resistance to airborne dust and particulate contamination — validated by its IP65 enclosure — ensures consistent beam transmission even in environments where coal dust, silica, or ore fines are present in the air. Combined with a Rockwell Automation GuardLogix safety controller and Allen-Bradley PowerFlex 755 drives with STO, the curtain forms part of a complete conveyor safety system that meets AS 4024.3 machinery safety standards.
In power generation and electrical utilities, the NA2-N16D protects maintenance personnel working near high-voltage switchgear, transformer bays, and turbine access platforms. Its EMI immunity — compliant with IEC 61000-4-3 radiated immunity and IEC 61000-4-4 electrical fast transient standards — ensures that the safety function is not compromised by the intense electromagnetic fields generated by high-voltage switching operations or nearby bus bars.
In water and wastewater treatment, the NA2-N16D guards access points to pump stations, chemical dosing areas, and UV disinfection chambers. The unit’s resistance to high-humidity environments (up to 95% RH non-condensing) and its sealed housing prevent moisture ingress that could cause optical degradation or electronic failure over extended service periods.
In steel and metallurgical plants, the NA2-N16D operates in the presence of radiant heat from furnaces, infrared radiation from molten metal, and heavy mechanical vibration from rolling mills and forging presses. Its fast response time of ≤14 ms ensures that personnel intrusion is detected and the machine stopped before contact with hazardous moving parts — a non-negotiable requirement in environments where a delayed safety response could result in catastrophic injury.
Q1: What does the 12-month warranty cover for the NA2-N16D?
The 12-month warranty covers all manufacturing defects, component failures, and functional malfunctions under normal operating conditions. If the unit fails to perform its specified safety function within the warranty period due to a manufacturing defect, TOPNLMS will provide a replacement unit at no charge. The warranty period begins from the date of shipment. Physical damage caused by incorrect installation, overvoltage, or unauthorized modification is excluded.
Q2: What pre-shipment testing is performed on each NA2-N16D unit?
Every NA2-N16D unit undergoes a structured pre-shipment inspection that includes: (1) OSSD dual-channel output verification under 24 V DC supply, (2) beam alignment and transmission check across all 16 beams, (3) insulation resistance test between supply conductors and housing, and (4) visual inspection of the housing, connectors, and optical windows. A test record is maintained for each unit and is available upon request.
Q3: Is the NA2-N16D compatible with my existing Panasonic NA2 Series installation?
Yes. The NA2-N16D is designed as a direct form-fit-function replacement within the Panasonic NA2 Series. Its mounting dimensions, connector pinout, and OSSD output characteristics are compatible with existing NA2 Series emitter/receiver pairs and associated safety relay wiring. No modifications to the control cabinet wiring or safety relay configuration are required in most standard replacement scenarios. If your installation uses a non-standard muting or blanking configuration, contact our technical team before ordering.
Q4: Can TOPNLMS guarantee long-term supply and replacement support for the NA2-N16D?
Yes. TOPNLMS maintains a dedicated inventory of Panasonic NA2 Series safety light curtains, including the NA2-N16D, to support both planned maintenance programs and emergency breakdown replacements. We work directly with authorized distribution channels to ensure continuity of supply even for products approaching end-of-production status. For customers with large installed bases, we recommend discussing a consignment stock or scheduled replenishment arrangement to eliminate lead-time risk during critical production periods. Contact us at [email protected] or +86 18359293191 to discuss your requirements.
Click Quote This Model and the Part Number field will auto-fill with NA2-N16D.