Language English USD Currency
Call WhatsApp RFQ
Mitsubishi Industrial Automation Part

Mitsubishi GB250H-3F Replacement/Upgrade for GB Series

Request availability, condition, lead time and export shipping details for GB250H-3F.

Mitsubishi

GB250H-3F

Send this exact part number, quantity and destination country. TOPNLMS will confirm availability, condition and export lead time before quotation.

Part NumberGB250H-3F
CategoryPLC
ConditionAvailability Check
Lead TimeRFQ Confirmation
SeriesUpgrade for GB Series
ShippingExport packing available
Model checked before quotation Condition and packing confirmed Fast RFQ response by sales engineer

Product Overview

Mitsubishi GB250H-3F Replacement/Upgrade for GB Series: Seamless Transition from Legacy UPS Battery Systems

When your Mitsubishi GB Series industrial UPS battery module reaches end-of-life or becomes difficult to source, unplanned downtime is the greatest risk to your production line. The Mitsubishi GB250H-3F is a direct-fit replacement and upgrade solution engineered for facilities running legacy Mitsubishi GB Series uninterruptible power supply systems. Whether you are maintaining a MELSEC PLC control cabinet, a MELSERVO drive system, or a distributed I/O rack that depends on battery-backed power continuity, the GB250H-3F delivers a verified drop-in upgrade path with no rewiring, no firmware changes, and no structural modification to your existing control panel.

Many facilities still operate control architectures built around the Mitsubishi MELSEC Q Series or A Series PLCs, where the UPS battery module plays a critical role in protecting program memory, retaining data registers, and sustaining real-time clock functions during power interruptions. The GB250H-3F is dimensionally and electrically compatible with the original GB Series battery bay, meaning your maintenance team can complete the swap during a scheduled maintenance window without specialist tooling. The module connects via the same standardized battery connector used across the GB Series platform, eliminating the need to re-terminate wiring or modify the battery housing bracket inside the control cabinet.

For sites transitioning from older Mitsubishi A Series or FX Series PLC installations to newer MELSEC iQ-R or iQ-F platforms, the GB250H-3F can serve as an interim power continuity solution during the migration phase. During a staged retrofit, it is common to run the legacy and new control systems in parallel. In these scenarios, maintaining reliable battery backup across both the old MELSEC Q02CPU or Q06HCPU controller and the new iQ-R Series rack is essential. The GB250H-3F supports this parallel operation period without requiring a separate UPS infrastructure investment.

Communication module continuity is another critical consideration during system upgrades. Modules such as the QJ71E71-100 Ethernet interface or the QJ71C24N RS-232/RS-485 serial communication module depend on stable power to maintain active connections with SCADA systems, HMI panels, and field devices. A battery module failure during a live migration can corrupt communication parameter tables and force a full re-commissioning of the network topology. Installing a verified GB250H-3F before beginning any migration work eliminates this risk and protects the integrity of your communication configuration throughout the transition.

In drive system environments, the GB250H-3F is frequently deployed alongside Mitsubishi MELSERVO MR-J4 or MR-J3 servo amplifiers and FR-A800 Series variable frequency drives, where the UPS battery module provides backup power to the control circuit during emergency stop sequences and power recovery cycles. Maintaining battery integrity in these applications prevents encoder position loss and protects regenerative braking parameter settings that are critical to safe machine restart after a power event.

For I/O-intensive applications using QX Series digital input modules, QY Series digital output modules, or QD Series analog I/O modules mounted on a Q Series base unit, the GB250H-3F ensures that the CPU module retains its I/O assignment table and special relay/register states during power interruptions. This is particularly important in process control environments where losing I/O configuration data requires a full system re-scan and validation before production can resume.

Physical installation is straightforward. The GB250H-3F slides into the existing battery slot on the GB Series UPS unit, engages the retention latch, and connects via the keyed battery connector. No additional mounting hardware, DIN rail adapters, or panel cutout modifications are required. The module’s compact form factor is compatible with standard 19-inch rack-mount control cabinets as well as freestanding floor-mount enclosures commonly found in automotive, food processing, and water treatment facilities.

Compatibility Comparison Table

Parameter Legacy / Outgoing Module GB250H-3F (Replacement)
Model / SKU GB Series (prior generation) GB250H-3F
Brand Mitsubishi Electric Mitsubishi Electric
Series GB Series UPS Battery GB Series UPS Battery
Battery Chemistry Sealed Lead-Acid / NiMH (varies) Lithium-based (GB250H-3F spec)
Connector Interface GB Series keyed battery connector GB Series keyed battery connector (direct fit)
Mounting Slide-in battery bay Slide-in battery bay (no modification)
Communication Compatibility MELSEC Q / A / FX Series MELSEC Q / iQ-R / iQ-F / A / FX Series
Panel Space Requirement Standard GB Series bay Standard GB Series bay (identical footprint)
Replacement Complexity N/A Tool-free, hot-swap capable (check UPS model)
Warranty N/A 12-Month Warranty (TOPNLMS)

Seamless Upgrade Solutions

A complete GB250H-3F migration typically involves coordinating several interdependent components within the same control cabinet. During the battery module swap, it is an ideal time to inspect and, if necessary, replace the Q Series power supply module (such as the Q61P or Q62P) that feeds the CPU and I/O base unit, since power supply degradation is often concurrent with battery module aging. If your installation includes a QJ71BR11 MELSECNET/H network module or a QJ71GF11-T2 CC-Link IE Field master module, verifying their firmware versions and communication parameter backups before the battery swap ensures that network topology is preserved across the maintenance window.

Sites using GOT2000 Series HMI panels (such as the GT2710-VTBA) connected to the MELSEC Q or iQ-R CPU via RS-422 or Ethernet should confirm that the HMI project file is backed up to a CF card or USB memory before beginning the battery replacement, as some HMI models store recipe data and alarm history in battery-backed SRAM. Similarly, if your control system includes a QD75MH4 positioning module or an RD77MS4 Simple Motion module, encoder origin data and cam data should be exported to the engineering workstation via GX Works3 or MT Developer2 prior to the swap.

For facilities using CC-Link field network devices — including remote I/O stations, intelligent device stations, and local stations connected via the QJ61BT11N CC-Link master module — the GB250H-3F replacement can be completed without disrupting the CC-Link network if the UPS unit supports hot-swap battery replacement. Always consult the specific UPS model’s hardware manual to confirm hot-swap eligibility before proceeding on a live system.

Retrofit Guidance FAQ

Q: Does the GB250H-3F require any wiring changes during installation?
A: No. The GB250H-3F uses the same keyed battery connector as the original GB Series battery module. No re-termination or wiring modification is required. Simply disconnect the old module, slide in the GB250H-3F, and reconnect the battery connector.

Q: Will replacing the battery module affect my PLC program or data registers?
A: If the UPS unit maintains power to the CPU during the battery swap (hot-swap capable), program memory and data registers are preserved. If the UPS must be powered down, back up your MELSEC CPU program and device data to a memory card or PC via GX Works2 / GX Works3 before proceeding.

Q: Is the GB250H-3F compatible with both MELSEC Q Series and iQ-R Series control systems?
A: Yes. The GB250H-3F is compatible with the GB Series UPS units used across MELSEC Q, iQ-R, iQ-F, A, and FX Series control architectures. The UPS unit itself interfaces with the control system; the battery module replacement does not affect PLC series compatibility.

Q: What communication protocols are supported after the upgrade?
A: The GB250H-3F replacement does not alter communication protocol support. Your existing MELSECNET/H, CC-Link, CC-Link IE Field, Ethernet (SLMP/MC Protocol), RS-232, and RS-485 configurations remain unchanged after the battery module swap.

Q: How much physical space does the GB250H-3F require in the control cabinet?
A: The GB250H-3F has an identical footprint to the original GB Series battery module. No additional panel space, DIN rail extension, or enclosure modification is required.

Q: Can the GB250H-3F be used as a spare part for preventive maintenance programs?
A: Yes. We recommend holding at least one GB250H-3F as a critical spare in your maintenance inventory, particularly for facilities with 24/7 production schedules where unplanned downtime carries significant cost.

Warranty Assurance

Every GB250H-3F shipped by TOPNLMS is covered by a 12-month warranty from the date of delivery. Prior to shipment, each unit undergoes functional verification including voltage output testing, connector integrity inspection, and capacity verification to ensure it meets or exceeds the original Mitsubishi Electric specification. In the event of a confirmed defect within the warranty period, TOPNLMS will arrange a replacement unit or issue a full refund — whichever resolution best minimizes your downtime.

Orders are processed and dispatched from our Xiamen warehouse within 1–3 business days. Express international shipping options are available for urgent replacement requirements. All units are packaged in anti-static protective packaging with individual serial number labeling for traceability. Our after-sales team is available via email and phone to support installation queries, compatibility verification, and warranty claims throughout the 12-month coverage period.

For bulk procurement, OEM replacement programs, or scheduled maintenance contracts requiring multiple GB250H-3F units, please contact our sales team directly to discuss volume pricing and lead time commitments.

Quick Inquiry

Click Quote This Model and the Part Number field will auto-fill with GB250H-3F.