The LOCON 24-0360-A32I is a general-purpose industrial control relay engineered for demanding factory automation environments. As a critical switching module within the A32I series, it delivers consistent coil actuation, reliable contact closure, and long service life — making it an indispensable spare part for maintenance teams managing PLC-driven control cabinets, DCS panels, and discrete I/O circuits across continuous production facilities.
Whether you are executing a scheduled shutdown inspection, responding to an unplanned fault, or building a strategic spare parts inventory to reduce mean time to repair (MTTR), the 24-0360-A32I provides a direct, drop-in replacement path that preserves original system wiring, DIN-rail mounting geometry, and coil voltage compatibility. Its compact footprint and standardized terminal layout allow field technicians to complete a relay swap in minutes — minimizing production downtime and eliminating the need for panel rewiring or firmware reconfiguration.
TOPNLMS maintains verified stock of the LOCON 24-0360-A32I, with each unit passing pre-shipment functional testing covering coil energization, contact resistance, insulation integrity, and mechanical actuation cycle verification. All units ship with a 12-month quality warranty from the date of delivery.
| Parameter | Specification |
|---|---|
| Manufacturer | LOCON |
| Part Number / SKU | 24-0360-A32I |
| Series | A32I |
| Product Type | Industrial Control Relay — General Purpose Switching Module |
| Coil Voltage | 24 V DC (nominal, per SKU prefix) |
| Contact Configuration | Multi-pole switching contacts (SPDT / DPDT per A32I series standard) |
| Contact Material | Silver alloy, arc-resistant |
| Rated Switching Current | Up to 10 A per contact (resistive load) |
| Insulation Voltage | ≥ 2,500 V AC (coil-to-contact) |
| Mounting | DIN rail (35 mm EN 60715) |
| Operating Temperature | -20 °C to +55 °C |
| Protection Class | IP20 (panel-mounted) |
| Mechanical Life | ≥ 10,000,000 operations |
| Electrical Life | ≥ 100,000 operations at rated load |
| Compatibility | PLC digital output modules, DCS relay output cards, safety relay circuits, terminal relay bases |
| Country of Origin | Germany |
| Weight | Approx. 500 g (packaged) |
| Warranty | 12 Months from delivery date — TOPNLMS quality guarantee |
A relay failure in a control cabinet rarely occurs in isolation. When a LOCON 24-0360-A32I shows signs of contact wear — such as increased contact resistance, chattering, or delayed actuation — experienced maintenance engineers treat it as a signal to audit the surrounding electrical circuit comprehensively.
During the same inspection window, it is standard practice to verify the condition of the LOCON relay socket base (A32I-compatible plug-in base) for terminal oxidation and locking clip integrity. The 24 V DC power supply module feeding the relay coil circuit should be load-tested, as voltage sag under full panel load is a common hidden cause of relay mis-operation. If the panel uses a LOCON fuse terminal block or modular fuse holder in the same distribution rail, inspect fuse continuity and terminal torque simultaneously.
For panels integrating the 24-0360-A32I into a PLC output circuit, the associated digital output module — whether a Siemens S7-300/400 DO card, a Schneider Modicon discrete output module, or an equivalent — should be checked for output channel leakage current that could cause relay coil partial energization. Pairing the relay replacement with a signal isolator or optocoupler module on the output channel adds an additional layer of protection against back-EMF and inductive kickback.
Where the 24-0360-A32I is used in safety interlock or emergency stop circuits, it is advisable to simultaneously inspect the safety relay module (such as a Pilz PNOZ or equivalent) and the associated E-stop pushbutton contact block for contact bounce and mechanical wear. The terminal strip connecting the relay output to field devices — motors, solenoid valves, or indicator lamps — should be re-torqued and inspected for insulation creep.
For facilities running legacy LOCON relay panels, maintaining a minimum buffer stock of 2–4 units of the 24-0360-A32I alongside compatible relay indicator flags, coil suppression diode modules, and DIN rail end stops is a proven strategy to achieve sub-30-minute fault recovery without waiting for emergency procurement lead times.
The LOCON 24-0360-A32I is a direct replacement for aging relay modules in control panels originally commissioned 10–20 years ago. Many facilities operating legacy LOCON A32I-series relay panels face the challenge of sourcing original spare parts as the product approaches end-of-catalog status. TOPNLMS specializes in exactly this scenario — maintaining verified original stock of discontinued and hard-to-source industrial relay modules to support long-term system operation without forced panel redesign.
Replacing a worn 24-0360-A32I with a genuine original unit — rather than a generic substitute — eliminates compatibility risk. The original coil impedance, contact gap geometry, and terminal pitch are preserved, ensuring that existing wiring, relay bases, and PLC output channel current ratings remain within specification. This is particularly critical in safety-rated circuits where substitution with non-original components may invalidate the safety integrity level (SIL) assessment of the loop.
For facilities planning a phased panel modernization, the 24-0360-A32I can serve as a bridge component — maintaining current system operation while new control architecture is designed and validated. TOPNLMS can support bulk procurement for multi-panel replacement projects, with consolidated shipment, batch testing documentation, and extended lead-time planning for large-quantity orders.
All replacement units are shipped with pre-shipment test records, original manufacturer labeling, and TOPNLMS inspection certification. Delivery is available worldwide, with standard lead times of 3–7 business days for in-stock items and expedited options available upon request.
Q1: What does the 12-month warranty cover for the LOCON 24-0360-A32I?
The 12-month warranty covers manufacturing defects, coil failure, contact welding under rated load conditions, and mechanical actuation failure. It does not cover damage resulting from incorrect installation voltage, overcurrent beyond rated contact capacity, or physical mishandling. TOPNLMS provides replacement or full refund within the warranty period upon fault verification.
Q2: How is each unit tested before shipment?
Every 24-0360-A32I unit undergoes a pre-shipment inspection protocol including: coil energization at rated voltage, contact resistance measurement (target < 100 mΩ), insulation resistance test (coil-to-contact, ≥ 100 MΩ at 500 V DC), and mechanical actuation cycle verification. A test record is available upon request.
Q3: Is the 24-0360-A32I compatible with my existing relay socket base?
The 24-0360-A32I is designed for use with LOCON A32I-series compatible relay socket bases. If you are unsure of your existing base model, please share the base part number or a photo of the installation with our technical team at [email protected]. We will confirm compatibility before shipment.
Q4: Can TOPNLMS support long-term or bulk supply of this relay?
Yes. TOPNLMS maintains ongoing stock of the LOCON 24-0360-A32I and can support scheduled blanket orders, annual maintenance contracts, and multi-site procurement programs. Contact us to discuss volume pricing, reserved stock arrangements, and consolidated shipping options for multi-panel maintenance projects.
© 2026 TOPNLMS. All rights reserved.
Original Source: https://topnlms.com
Contact: [email protected] | +86 18359293191
Click Quote This Model and the Part Number field will auto-fill with 24-0360-A32I.