Language English USD Currency
Call WhatsApp RFQ
Kollmorgen Industrial Automation Part

KOLLMORGEN AKD-P01206-NBCC-I000 Original Industrial Spare AKD Compatible

Request availability, condition, lead time and export shipping details for AKD-P01206-NBCC-I000.

Kollmorgen

AKD-P01206-NBCC-I000

Send this exact part number, quantity and destination country. TOPNLMS will confirm availability, condition and export lead time before quotation.

Part NumberAKD-P01206-NBCC-I000
CategoryVFD
ConditionAvailability Check
Lead TimeRFQ Confirmation
SeriesOther series
ShippingExport packing available
Model checked before quotation Condition and packing confirmed Fast RFQ response by sales engineer

Product Overview

KOLLMORGEN AKD-P01206-NBCC-I000 Original Industrial Spare AKD Compatible: Sustaining System Stability in Demanding Automation Environments

In modern industrial facilities, servo drive reliability is the backbone of continuous production. The KOLLMORGEN AKD-P01206-NBCC-I000 is a genuine original AKD Series EtherCAT servo drive rated at 12 A continuous output current, engineered for precision motion control in high-demand manufacturing, packaging, printing, and material handling applications. Maintaining an available stock of this unit directly reduces unplanned downtime risk, shortens mean time to repair (MTTR), and protects the long-term viability of existing KOLLMORGEN AKD-based control architectures.

Whether you are managing a planned shutdown, responding to an emergency fault, or executing a preventive maintenance cycle, having the AKD-P01206-NBCC-I000 on hand ensures your servo axis is back online with zero compatibility risk and no re-commissioning surprises.

Critical Technical Specs

Parameter Specification
Part Number / SKU AKD-P01206-NBCC-I000
Brand / Manufacturer KOLLMORGEN
Series AKD (Advanced Kollmorgen Drive)
Continuous Output Current 12 A
Peak Output Current 24 A (2× rated, typical AKD profile)
Fieldbus / Communication EtherCAT (CoE — CiA 402 motion profile)
Feedback Interface SFD3 / EnDat 2.2 / Resolver / Hiperface (model-dependent)
Supply Voltage 120–240 V AC, single or three-phase
Control Mode Position / Velocity / Torque (CSP, CSV, CST)
Protection Class IP20 (panel-mount, cabinet installation)
Operating Temperature 0 °C to +40 °C (derate above 40 °C)
Country of Origin Germany
Product Type Servo Drive / Motion Controller
Compatibility KOLLMORGEN AKD Series servo motors; AKD-B, AKD-P, AKD-T variants; KAS (Kollmorgen Automation Suite) platform
Mounting DIN rail or panel mount; standard AKD footprint
Warranty 12 Months from shipment date
Condition Original / Genuine — tested before dispatch

Preventive Maintenance Strategy

A servo drive fault rarely occurs in isolation. When the AKD-P01206-NBCC-I000 is flagged for replacement during a scheduled inspection or emergency shutdown, experienced maintenance engineers know that the surrounding components in the same control cabinet deserve equal scrutiny. Ignoring adjacent hardware is one of the most common causes of repeat failures within weeks of a servo drive swap.

Begin by inspecting the 24 V DC control power supply feeding the AKD logic bus — voltage ripple or marginal capacity is a frequent hidden cause of drive faults. At the same time, verify the condition of the AKD mains filter module and the line reactor or EMC choke upstream of the drive; degraded filtering directly impacts drive longevity and EtherCAT communication stability. The brake resistor or regenerative braking unit connected to the DC bus should be checked for thermal discoloration or resistance drift, particularly in high-cycle applications.

On the motor side, inspect the KOLLMORGEN AKM or AKD-compatible servo motor paired with this drive — bearing wear, winding insulation degradation, and encoder signal integrity issues can all manifest as drive overcurrent or feedback faults. The motor power cable and feedback cable assembly (typically KOLLMORGEN CFD or equivalent shielded cable) should be checked for chafing, connector pin corrosion, and shield continuity, as cable faults are a leading cause of nuisance drive trips in mobile or high-flex installations.

Within the EtherCAT network topology, verify the EtherCAT master controller or IPC (such as a Beckhoff CX or PC-based KAS controller) and the EtherCAT switch or junction module for port integrity and firmware currency. A degraded network segment can cause intermittent axis faults that are incorrectly attributed to the drive itself. Additionally, review the I/O terminal modules connected to the AKD’s digital I/O — worn relay contacts or leaky transistor outputs on adjacent I/O modules can inject false enable or fault-reset signals.

Finally, inspect the cabinet terminal blocks and bus bars for loose connections and oxidation, and confirm that the safety relay module or STO (Safe Torque Off) circuit wiring is intact and correctly routed. A compromised STO channel is a common cause of unexplained drive disable events that are difficult to diagnose without systematic cabinet inspection.

Stocking the AKD-P01206-NBCC-I000 alongside these complementary components as part of a structured spare parts kit is the most cost-effective strategy for minimizing servo axis downtime across your facility.

Strategic Replacement Solutions

The KOLLMORGEN AKD platform was introduced as a successor to the legacy S700 and Servostar 600 series drives. Facilities still operating older KOLLMORGEN Servostar 601, 603, or 620 units face increasing obsolescence risk as spare parts availability tightens and firmware support ends. The AKD-P01206-NBCC-I000 provides a direct migration path for 12 A axis applications, retaining compatibility with KOLLMORGEN AKM servo motors and reducing the need for motor rewiring or mechanical modifications.

For multi-axis systems, replacing aging drives one axis at a time — rather than waiting for a full system failure — is the preferred strategy. The AKD’s EtherCAT interface integrates seamlessly into existing KAS or third-party EtherCAT master environments, meaning a single-axis replacement can be completed during a short maintenance window without disrupting the broader machine program. Drive parameters can be backed up and restored via WorkBench software, further reducing commissioning time to under 30 minutes for experienced technicians.

Maintaining one or two AKD-P01206-NBCC-I000 units in your on-site spare parts inventory eliminates the lead time risk associated with emergency procurement — particularly critical for facilities operating 24/7 production schedules where a single servo axis fault can halt an entire production line. The 12-month warranty on each unit ensures that your inventory investment is protected from the moment of shipment.

Support FAQ

Q1: Is the AKD-P01206-NBCC-I000 a direct drop-in replacement for other AKD 12 A variants?
A: Yes, within the AKD-P sub-family, units sharing the same current rating and fieldbus option (NBCC = EtherCAT, no safe motion, standard I/O) are mechanically and electrically interchangeable. Parameter files created in KOLLMORGEN WorkBench can be transferred directly, making axis swap-out straightforward. Always verify the feedback type suffix matches your motor encoder before installation.

Q2: What is the recommended spare parts inventory strategy for AKD-based systems?
A: Industry best practice for critical servo axes is to maintain a minimum of one spare drive per unique current rating in use on-site. For facilities with 10 or more AKD axes, a ratio of one spare per five drives is commonly adopted. Drives stored in original packaging in a climate-controlled environment retain full specification for 3–5 years without requiring re-certification.

Q3: How is the unit tested and verified before shipment?
A: Each AKD-P01206-NBCC-I000 unit undergoes functional power-on verification and EtherCAT communication testing prior to dispatch. Units are shipped in anti-static packaging with original accessories where available. A 12-month warranty from the shipment date covers manufacturing defects and functional failures under normal operating conditions.

Q4: Can this drive be used with non-KOLLMORGEN servo motors?
A: The AKD platform supports third-party motors with compatible feedback devices (EnDat 2.2, Hiperface, resolver) through its universal feedback interface. However, KOLLMORGEN AKM series motors are the validated and recommended pairing for optimal performance and warranty coverage. Compatibility with third-party motors should be verified against the AKD Installation Manual prior to commissioning.

Quick Inquiry

Click Quote This Model and the Part Number field will auto-fill with AKD-P01206-NBCC-I000.