Product Overview
Honeywell TK-CCR014 Replacement for Experion PKS C300: Seamless DCS Migration & Upgrade Solution
The Honeywell TK-CCR014 is the Redundant Network Interface Module (RNIM) designed for the Experion PKS C300 Controller platform — one of the most widely deployed distributed control system architectures in the process automation industry. As legacy C300 systems age and original TK-CCR014 units reach end-of-service life, facilities across petrochemical, power generation, pulp & paper, and pharmaceutical sectors are actively seeking verified replacement and upgrade paths that preserve existing wiring infrastructure, control logic, and communication topology.
TOPNLMS supplies the TK-CCR014 as a direct drop-in replacement module, sourced from authorized channels and rigorously tested prior to shipment. Whether your facility is executing a like-for-like spare replacement, a partial system refresh, or a full DCS migration from an older Honeywell TDC 3000 or PlantScape platform to the current Experion PKS architecture, the TK-CCR014 is the critical communication backbone that enables redundant FTE (Fault Tolerant Ethernet) connectivity between the C300 controller and the supervisory network.
Compatibility Comparison Table
| Parameter |
Legacy / Replaced Module |
TK-CCR014 (Replacement) |
| Module Role |
Redundant Network Interface (older RNIM variants) |
Redundant Network Interface Module for C300 |
| Compatible Controller |
C300 Controller (TK-CCR001 / TK-CCR013 era) |
C300 Controller — all firmware revisions |
| Communication Protocol |
FTE (Fault Tolerant Ethernet) / Ethernet/IP |
FTE (Fault Tolerant Ethernet) — fully compatible |
| Rack / Backplane |
C300 Series Control Rack |
C300 Series Control Rack — direct slot replacement |
| Wiring Interface |
RJ-45 dual-port FTE connection |
RJ-45 dual-port FTE — no rewiring required |
| Power Supply |
Rack-supplied 24 VDC |
Rack-supplied 24 VDC — no external PSU change |
| Physical Dimensions |
Standard C300 module form factor |
Identical form factor — no cabinet modification |
| Firmware Compatibility |
Experion PKS R310 and above |
Experion PKS R310 through current release |
| Redundancy Support |
Active/Standby redundancy |
Active/Standby redundancy — seamless failover |
| Replacement Recommendation |
Direct swap; no logic re-download required in most cases |
Confirm firmware revision match before hot-swap |
| Warranty |
OEM warranty expired (legacy units) |
12-Month Warranty from TOPNLMS |
Seamless Upgrade Solutions
A successful TK-CCR014 replacement rarely occurs in isolation. In most C300 DCS modernization projects, the network interface module is replaced as part of a broader system refresh that may also involve the C300 Controller module itself (TK-CCR001 or TK-CCR013), which shares the same rack slot architecture and FTE communication framework. Facilities upgrading from older Honeywell TDC 3000 hardware — including legacy UCN (Universal Control Network) nodes and AM/PM modules — will typically migrate their I/O subsystems to the Series C I/O platform, using modules such as the TC-OAV081 analog output module or TC-IAH081 high-density analog input module, which integrate directly into the C300 control strategy without requiring full logic rewrites.
On the network side, the TK-CCR014 operates within the FTE switch infrastructure. Upgrading the FTE network switches — such as the Honeywell CC-TCF901 FTE switch — in parallel with the RNIM replacement ensures that the redundant communication path performs at specification. For facilities also refreshing their SCADA or operator station layer, the Experion PKS Station (EPKS Station) software and associated server hardware upgrades should be coordinated with the C300 firmware revision to maintain compatibility across the supervisory and control tiers.
Projects that include I/O expansion or migration from legacy HLAI/LLAI termination assemblies will benefit from reviewing the CC-TAIX11 and CC-TAOX11 termination assemblies, which provide the field wiring interface for Series C I/O modules and eliminate the need for rewiring at the marshalling cabinet. For facilities with safety-instrumented systems running on Honeywell Safety Manager or legacy FSC platforms, the TK-CCR014 upgrade path should be validated against the safety network architecture to confirm that the FTE backbone does not introduce latency into the SIS communication loop.
In control cabinet environments where space is constrained, the compact form factor of the TK-CCR014 — identical to all C300-series modules — means that no additional DIN rail, mounting bracket, or cabinet modification is required. Power distribution within the rack is handled by the existing C300 power supply module (TK-PSA124 or equivalent), and no additional power conditioning is needed for the replacement module.
Retrofit Guidance FAQ
Q: Can I hot-swap the TK-CCR014 without shutting down the C300 controller?
A: In redundant configurations where a standby RNIM is active, the failed primary module can typically be replaced without a full controller shutdown. However, Honeywell recommends confirming the firmware revision of the replacement module matches the installed base before performing a live swap. TOPNLMS provides firmware revision documentation with each unit upon request.
Q: Will my existing FTE cabling work with the replacement TK-CCR014?
A: Yes. The TK-CCR014 uses standard RJ-45 dual-port FTE connections. No rewiring is required at the field or cabinet level. The module slots directly into the C300 rack and connects to the existing FTE switch infrastructure.
Q: Do I need to re-download my control strategy after replacing the TK-CCR014?
A: In most cases, no. The C300 controller retains its loaded strategy in non-volatile memory. After the RNIM replacement, the controller re-establishes FTE communication automatically. A full strategy download is only required if the controller module itself is also being replaced.
Q: Is the TK-CCR014 compatible with all Experion PKS software releases?
A: The TK-CCR014 is compatible with Experion PKS R310 and all subsequent releases through the current version. For installations running pre-R310 firmware, a firmware upgrade of the C300 controller is recommended prior to installing the replacement RNIM.
Q: What is the physical installation space requirement?
A: The TK-CCR014 occupies a single slot in the standard C300 Series Control Rack. No additional mounting hardware, cable management, or cabinet modification is required. The module is mechanically identical to all other C300-series modules.
Q: Can the TK-CCR014 be used in a non-redundant C300 configuration?
A: Yes. While the module is designed to support redundant FTE communication, it can be installed in a simplex (non-redundant) C300 configuration. In this case, only one FTE port is active, and the redundancy failover feature is not utilized.
Warranty Assurance
Every TK-CCR014 unit supplied by TOPNLMS is covered by a 12-Month Warranty from the date of shipment. Prior to dispatch, each module undergoes a multi-point functional inspection that includes power-on verification, FTE port communication testing, backplane connector integrity check, and firmware revision confirmation. Units that do not pass inspection are not shipped.
In the event of a warranty claim, TOPNLMS provides a direct replacement unit — not a repair-and-return service — to minimize your facility’s downtime. Our average response time for warranty replacement requests is within 2 business days of claim confirmation. Replacement units are shipped from our Xiamen warehouse via DHL Express or equivalent international courier, with tracking provided at the time of dispatch.
For procurement teams requiring documentation, TOPNLMS can provide a test report, packing list, and certificate of conformity with each order. Lead time for in-stock units is typically 3–7 business days for international destinations. Expedited shipping options are available upon request.
For purchasing inquiries, technical compatibility questions, or warranty claims, contact our industrial automation team directly:
📧 [email protected]
📞 +86 18359293191