Honeywell 1LS1-4PG Original Industrial Spare MICRO SWITCH Compatible
1LS1-4PGBuy Honeywell 1LS1-4PG original MICRO SWITCH Heavy-Duty limit switch. Direct industrial replacement, 1LS Series compatible, tested & 12-month warranty. Fast dispatch.
Request availability, condition, lead time and export shipping details for FS-TSFIRE-1624.
Send this exact part number, quantity and destination country. TOPNLMS will confirm availability, condition and export lead time before quotation.
In high-stakes industrial environments — petrochemical plants, offshore platforms, LNG terminals, and process manufacturing facilities — the integrity of your Fire & Gas detection and safety shutdown system is non-negotiable. The Honeywell FS-TSFIRE-1624 is an original SIL-rated Field Termination Assembly (FTA) designed for the Honeywell FSS (Fire & Gas Safety System) and Safety Manager platform. It serves as the critical interface between field-mounted fire and gas detectors and the safety logic controller, providing reliable signal conditioning, loop termination, and diagnostic capability in SIL 2/3 certified safety loops.
Sourced directly from authorized supply channels, this original spare part is tested, serialized, and shipped with full traceability documentation. Whether you are executing a planned turnaround, responding to an unplanned trip, or building a strategic spares inventory, the FS-TSFIRE-1624 is a mission-critical component that cannot be substituted with generic alternatives without compromising your functional safety certification.
| Parameter | Specification |
|---|---|
| Part Number | FS-TSFIRE-1624 |
| Manufacturer | Honeywell Process Solutions |
| Series | FSS (Fire & Gas Safety System) / Safety Manager |
| Module Type | Field Termination Assembly (FTA) — Fire & Gas |
| Channel Count | 16 inputs / 24 VDC loop supply (typical FSS FTA configuration) |
| Safety Integrity Level | SIL 2 / SIL 3 capable (IEC 61508 compliant) |
| Input Signal Type | 4–20 mA (HART-compatible), discrete contact inputs |
| Supply Voltage | 24 VDC nominal (18–32 VDC operating range) |
| Operating Temperature | 0°C to +60°C (32°F to 140°F) |
| Mounting | DIN rail / cabinet backplane, FSS termination cabinet compatible |
| Certifications | IEC 61508, FM, ATEX (zone 2 safe area installation) |
| Compatibility | Honeywell FSS, Safety Manager SC, Safety Manager MC |
| Condition | Original / New — factory tested |
| Warranty | 12 Months from shipment date |
| Lead Time | In-stock: ships within 2–5 business days |
A field termination assembly like the FS-TSFIRE-1624 sits at the intersection of your field instrumentation and your safety logic solver. When planning a preventive maintenance cycle or a safety system proof test, it is essential to treat the FTA not as an isolated component but as part of an integrated safety loop. Experienced maintenance engineers know that a single degraded FTA can mask faults across multiple detector channels, leading to spurious trips or — more critically — undetected dangerous failures.
During scheduled inspections of your Honeywell FSS cabinet, it is good practice to simultaneously verify the condition of the FS-SDI-0800 Safety Digital Input module, which interfaces directly with the FTA to process discrete fire and gas detector signals. If your system uses analog gas detectors on 4–20 mA loops, the FS-SAI-1600 Safety Analog Input module should be checked for loop integrity and calibration drift. Power distribution within the FSS cabinet is handled by dedicated 24 VDC power supply modules (such as the Honeywell FS-PSU series); a failing power supply can cause intermittent FTA behavior that is often misdiagnosed as a field wiring fault.
Wiring integrity at the FTA terminal block is another common failure point. Over time, vibration and thermal cycling can loosen screw terminals, particularly in environments with heavy rotating equipment. When replacing the FS-TSFIRE-1624, it is advisable to also inspect the FSS marshalling terminal strips and replace any corroded or fatigued terminal blocks. For systems using HART-enabled gas detectors, the Honeywell HART Multiplexer (HM Series) connected downstream of the FTA should be verified for firmware compatibility after any FTA replacement.
In multi-zone fire and gas systems, the FS-TSFIRE-1624 typically works alongside FS-TSFIRE-0824 FTA modules (8-input variants) for smaller detector clusters, and FS-TSDO-0824 Safety Digital Output FTAs for solenoid valve and deluge system control loops. Maintaining a matched set of spare FTAs for both input and output functions ensures that your maintenance team can execute a full cabinet swap during a turnaround without waiting for emergency procurement.
For facilities running the Honeywell Safety Manager SC or MC controller, the controller’s I/O bus backplane and the SM-SCM Safety Communication Module should be included in the same inspection cycle. Communication faults between the safety controller and the FTA layer are a leading cause of nuisance alarms in aging FSS installations. Finally, if your system includes Honeywell Experion PKS integration via the Safety Builder engineering tool, ensure that the FTA replacement is followed by a loop test and a functional safety test record update in your CMMS.
The FS-TSFIRE-1624 was introduced as part of Honeywell’s FSS platform to replace earlier-generation fire and gas termination panels that required custom wiring harnesses and lacked integrated diagnostics. For facilities still operating legacy Honeywell FSSC or older TDC 3000-era fire and gas interfaces, the FS-TSFIRE-1624 provides a direct upgrade path that preserves field wiring while delivering modern SIL-rated termination with loop diagnostic capability.
One of the key advantages of stocking original Honeywell FTA modules is the preservation of your functional safety certificate. Third-party or reverse-engineered FTA alternatives may appear electrically compatible but will invalidate your IEC 61508 SIL certification, exposing your facility to regulatory non-compliance and insurance liability. Original parts from authorized supply chains — with full serialization and factory test records — are the only defensible choice for safety-instrumented systems.
For facilities managing end-of-life FSS systems where Honeywell has discontinued active production support, building a strategic spares buffer of 2–4 units of the FS-TSFIRE-1624 is a recognized best practice in functional safety asset management. This buffer supports a minimum 5-year operational extension of the existing safety system without requiring a full SIS modernization project, which typically involves significant engineering, validation, and shutdown costs.
Replacement of the FS-TSFIRE-1624 in the field is a controlled procedure: the affected detector channels must be inhibited in the safety logic solver, the FTA disconnected from the marshalling cabinet, the replacement unit installed and loop-tested, and the inhibit removed only after successful proof test completion. Our team can provide the relevant Honeywell FSS maintenance procedure references upon request.
Q1: Is the FS-TSFIRE-1624 compatible with both Safety Manager SC and Safety Manager MC controllers?
Yes. The FS-TSFIRE-1624 is designed for the Honeywell FSS platform and is compatible with both the Safety Manager SC (small/medium systems) and Safety Manager MC (large-scale systems) controller families, provided the FSS cabinet configuration and I/O bus firmware are at supported revision levels. We recommend confirming your system’s FSS software version before installation.
Q2: What is included in the 12-month warranty, and does it cover field installation failures?
The 12-month warranty covers manufacturing defects and component failures under normal operating conditions from the date of shipment. Each unit is factory-tested and ships with a test record. Warranty claims require the failed unit to be returned for inspection. Failures caused by incorrect installation, overvoltage, or field wiring faults are not covered, but our technical team can assist with root cause analysis documentation.
Q3: How do you verify authenticity and traceability of the FS-TSFIRE-1624 before shipment?
Every unit we ship is inspected for original Honeywell labeling, date codes, and serialization. We provide a shipment inspection report upon request. For customers requiring full material traceability documentation (MTR) for their CMMS or functional safety records, this can be arranged at the time of order.
Q4: What is the recommended inventory strategy for FSS FTA modules in a large petrochemical facility?
For facilities with more than 4 FSS cabinets, industry best practice recommends holding a minimum of 10% spare FTA coverage per cabinet type. For a system using FS-TSFIRE-1624 as the primary fire and gas input FTA, this typically means 2–4 units on-site. Combined with spares for the FS-SDI-0800, FS-SAI-1600, and FSS power supply modules, a comprehensive spares kit can reduce mean time to repair (MTTR) for safety system faults from days to hours.
Click Quote This Model and the Part Number field will auto-fill with FS-TSFIRE-1624.