Language English USD Currency
Call WhatsApp RFQ
Honeywell Industrial Automation Part

Honeywell CC-TUIO31 51306875-176 Original Spare Experion PKS

Request availability, condition, lead time and export shipping details for CC-TUIO31 51306875-176.

Honeywell

CC-TUIO31 51306875-176

Send this exact part number, quantity and destination country. TOPNLMS will confirm availability, condition and export lead time before quotation.

Part NumberCC-TUIO31 51306875-176
CategoryI/O Module
ConditionAvailability Check
Lead TimeRFQ Confirmation
SeriesExperion PKS
ShippingExport packing available
Model checked before quotation Condition and packing confirmed Fast RFQ response by sales engineer

Product Overview

Honeywell CC-TUIO31 51306875-176 Original Spare — Experion PKS C300 System Stability

The Honeywell CC-TUIO31 (P/N 51306875-176) is an original Universal I/O Termination Board engineered for the Experion PKS C300 Distributed Control System. In process-critical environments — petrochemical plants, power generation facilities, pulp and paper mills, and continuous manufacturing lines — this termination board serves as the physical interface layer between field wiring and the C300 controller’s I/O modules. Its integrity is foundational to signal accuracy, loop stability, and overall DCS reliability.

When a termination board fails or degrades, the consequences extend far beyond a single I/O channel. Entire control loops can go offline, operators lose visibility into critical process variables, and unplanned shutdowns become unavoidable. Maintaining a verified original spare of the CC-TUIO31 in your on-site inventory is one of the most cost-effective risk mitigation strategies available to maintenance engineers managing aging Experion PKS installations.

This unit is sourced as an original Honeywell component, fully tested prior to shipment, and backed by a 12-month warranty. It is ready for immediate deployment in both emergency replacement and scheduled preventive maintenance scenarios.

Critical Technical Specs

Parameter Specification
Part Number CC-TUIO31 / 51306875-176
Manufacturer Honeywell Process Solutions
Series / Platform Experion PKS — C300 Controller Series
Module Type Universal I/O Termination Board
Compatible I/O Modules CC-PAIX01, CC-PAIX02, CC-TAIX01, CC-TAOX01 and compatible C300 I/O series
Mounting DIN rail / cabinet backplane, standard Experion PKS enclosure
Field Wiring Interface Screw-terminal field wiring connections, universal channel configuration
Operating Temperature 0°C to 60°C (32°F to 140°F)
Relative Humidity 5% to 95% non-condensing
Power Supply Supplied via backplane from C300 controller chassis
Country of Origin United States
Weight Approx. 440 g
Condition Original, tested before shipment
Warranty 12 Months
Application Environment Process industries: oil & gas, power, chemicals, pulp & paper, water treatment

Preventive Maintenance Strategy

Experienced DCS maintenance teams know that a termination board failure rarely occurs in isolation. The CC-TUIO31 sits at the intersection of field instrumentation and the C300 controller, making it a focal point during any scheduled cabinet inspection or corrective maintenance event. When your team opens the control cabinet to replace or inspect this board, it is best practice to simultaneously audit the surrounding components that share the same electrical environment and maintenance cycle.

Begin with the C300 Controller module (CC-PCF901) itself — verify firmware version, check for diagnostic alarms, and confirm that the controller is communicating cleanly with all associated I/O modules. Next, inspect the Universal I/O modules (CC-PAIX01 / CC-PAIX02) seated on the same chassis; these analog input modules share the termination board’s field wiring paths and are subject to the same environmental stresses. If any channel shows drift or intermittent faults, proactive replacement of the associated I/O module alongside the termination board eliminates a second maintenance window.

The C300 redundancy module (CC-PCF902) should also be verified during this inspection. Redundancy modules are often overlooked until a primary controller fault exposes a failed standby — a situation that transforms a manageable switchover into an unplanned outage. Similarly, the FIM (Firewall Interface Module, CC-FIM001) and associated FTE (Fault Tolerant Ethernet) network switches warrant a visual and diagnostic check, as network-layer faults can manifest as spurious I/O errors that are incorrectly attributed to the termination board.

Field wiring integrity is another critical dimension. Inspect the field terminal blocks and marshalling panels connected to the CC-TUIO31 for signs of corrosion, loose terminations, or insulation degradation. In humid or chemically aggressive environments, terminal block replacement on a 3–5 year cycle is a sound investment. If your installation uses signal isolators or signal conditioners between field instruments and the termination board, verify their calibration and check for thermal discoloration that may indicate overload conditions.

For sites running HART-enabled instruments through the CC-TUIO31’s universal channels, confirm that the HART multiplexer or HART interface module is functioning correctly and that asset management software is receiving live device diagnostics. A degraded HART communication path is a common early indicator of termination board contact wear.

Finally, review the 24 VDC power supply modules feeding the I/O cabinet. Power supply degradation — evidenced by output voltage ripple or reduced current headroom — accelerates wear on all downstream electronics including the termination board. Stocking a spare Honeywell CC-PWR001 or equivalent C300 cabinet power supply alongside the CC-TUIO31 is a prudent inventory strategy that covers the two most common cabinet-level failure modes in a single procurement action.

Strategic Replacement Solutions

The CC-TUIO31 (51306875-176) is a direct original replacement for aging or failed termination boards within the Experion PKS C300 platform. Unlike third-party alternatives that may require re-termination, re-configuration, or firmware compatibility verification, this original Honeywell board installs as a drop-in replacement with no changes to the existing field wiring schedule or DCS configuration database.

For plants operating legacy Experion PKS R310, R400, or R430 installations, the CC-TUIO31 remains fully compatible, allowing maintenance teams to extend the operational life of existing control infrastructure without committing to a costly platform migration. This is particularly valuable in industries where DCS migration projects carry multi-year timelines and significant process risk.

Replacement procedure is straightforward: isolate the affected I/O channels per your site’s Management of Change (MOC) procedure, de-energize the cabinet section, disconnect field wiring at the terminal block level, swap the termination board, reconnect and verify termination torque, restore power, and confirm channel-by-channel I/O health in the Experion Station. Total replacement time for a trained technician is typically under two hours, making the CC-TUIO31 one of the most maintainable components in the C300 architecture.

Procurement teams managing multi-site Honeywell DCS installations are encouraged to standardize on a minimum stock level of one CC-TUIO31 per control room, with additional units held at regional warehouses for sites with high I/O density or critical process loops. The 12-month warranty on each unit ensures that shelf stock remains covered from the date of activation, not the date of purchase.

Support FAQ

Q1: Is the CC-TUIO31 51306875-176 compatible with all Experion PKS C300 revisions?
A: Yes. The CC-TUIO31 is designed for the Experion PKS C300 platform and is compatible across standard C300 controller revisions including R310, R400, and R430 series installations. If your site runs a non-standard or heavily customized configuration, our technical team can assist with compatibility verification prior to shipment.

Q2: What testing is performed before shipment?
A: Every CC-TUIO31 unit undergoes functional testing prior to dispatch. Testing covers board-level power integrity, connector continuity, and visual inspection for physical damage. A test report is available upon request. All units ship with a 12-month warranty covering manufacturing defects and functional failures under normal operating conditions.

Q3: Can this board be installed as a hot-swap replacement without shutting down the entire DCS?
A: Termination board replacement typically requires isolation of the associated I/O channels and de-energization of the relevant cabinet section. Full hot-swap without any process impact is generally not supported for this board type. We recommend following your site’s MOC and LOTO procedures. Our team can provide guidance on minimizing process disruption during the replacement window.

Q4: What is your lead time and shipping policy?
A: In-stock units ship within 1–3 business days. We support worldwide shipping with tracking provided for all orders. Express freight options are available for emergency maintenance situations. Contact us directly for urgent requirements and we will prioritize your order accordingly.

Quick Inquiry

Click Quote This Model and the Part Number field will auto-fill with CC-TUIO31 51306875-176.