Language English USD Currency
Call WhatsApp RFQ
Honeywell Industrial Automation Part

Honeywell CC-TDOB01 CC-TDIL01 Replacement for Experion PKS C300

Request availability, condition, lead time and export shipping details for CC-TDOB01 CC-TDIL01.

Honeywell

CC-TDOB01 CC-TDIL01

Send this exact part number, quantity and destination country. TOPNLMS will confirm availability, condition and export lead time before quotation.

Part NumberCC-TDOB01 CC-TDIL01
CategoryI/O Module
ConditionAvailability Check
Lead TimeRFQ Confirmation
SeriesExperion PKS
ShippingExport packing available
Model checked before quotation Condition and packing confirmed Fast RFQ response by sales engineer

Product Overview

Honeywell CC-TDOB01 CC-TDIL01 Replacement for Experion PKS C300: Seamless Migration & Smooth Transition

Upgrading or replacing a Honeywell Experion PKS C300 digital I/O module does not have to mean extended downtime or costly re-engineering. The CC-TDOB01 (16-Channel Digital Output Module) and its companion CC-TDIL01 (16-Channel Digital Input Module) are purpose-built for the Experion PKS C300 controller platform, and TOPNLMS maintains verified stock of both to support urgent replacement, planned migration, and system expansion projects worldwide.

Whether your facility is retiring an aging TDC 3000 or PlantScape system, consolidating legacy I/O racks, or simply replacing a failed card to restore production, these modules slot directly into the existing C300 I/O Link architecture without requiring changes to your control strategy, wiring terminations, or cabinet layout.

Compatibility Comparison Table

Attribute CC-TDOB01 (Digital Output) CC-TDIL01 (Digital Input)
Channel Count 16 DO 16 DI
Platform Honeywell Experion PKS C300 Honeywell Experion PKS C300
I/O Link Protocol C300 I/O Link (proprietary) C300 I/O Link (proprietary)
Termination Compatible with CC-TBOX01 / CC-TBRC01 terminal blocks Compatible with CC-TBOX01 / CC-TBRC01 terminal blocks
Power Supply Powered via I/O Link backplane (no separate PSU required) Powered via I/O Link backplane (no separate PSU required)
Mounting C300 I/O chassis / carrier C300 I/O chassis / carrier
Signal Voltage 24 VDC nominal 24 VDC nominal
Replaces / Upgrades Failed or EOL CC-TDOB01 units; TDC 3000 DO cards via migration Failed or EOL CC-TDIL01 units; TDC 3000 DI cards via migration
Wiring Change Required None when replacing same model; terminal block re-use supported None when replacing same model; terminal block re-use supported
Control Strategy Change Not required for like-for-like replacement Not required for like-for-like replacement
Communication Protocol C300 I/O Link (auto-detected by controller) C300 I/O Link (auto-detected by controller)
Warranty (TOPNLMS) 12 Months from shipment date

Seamless Upgrade Solutions

A successful C300 I/O migration rarely involves a single module. In practice, engineers replacing the CC-TDOB01 or CC-TDIL01 also evaluate adjacent components to ensure the entire I/O subsystem is current and reliable.

The CC-TAIX01 Analog Input Module and CC-TAOX01 Analog Output Module share the same C300 I/O chassis and I/O Link backplane, making them natural candidates for simultaneous inspection or replacement during a planned outage. If your migration scope includes thermocouple or RTD inputs, the CC-TTIM01 Temperature Input Module integrates directly into the same rack without additional wiring adapters.

For facilities transitioning from older PlantScape or TDC 3000 architectures, the CC-PCF901 Process Controller Firewall and the C300 Controller Module itself are often upgraded in the same project window. The C300 controller communicates with all I/O modules — including the CC-TDOB01 and CC-TDIL01 — over the C300 I/O Link, so confirming controller firmware compatibility before swapping I/O cards is a standard pre-migration step.

Terminal infrastructure also deserves attention. The CC-TBOX01 and CC-TBRC01 terminal blocks connect field wiring to the I/O modules and can be reused in most replacement scenarios, eliminating the need to re-terminate field cables. However, if the terminal blocks show signs of corrosion or mechanical wear, replacing them alongside the I/O module is best practice.

Where the control cabinet includes a CC-PWR001 or equivalent Experion PKS power supply module, verifying load capacity after adding or replacing I/O cards ensures stable backplane voltage. For projects that extend the I/O network to remote cabinets, the CC-LINK01 I/O Link Extender maintains signal integrity over longer cable runs without requiring additional controllers.

Finally, commissioning engineers frequently use the Honeywell FTE (Fault Tolerant Ethernet) switch infrastructure alongside C300 I/O upgrades to ensure the supervisory network remains redundant and deterministic throughout the migration window.

Retrofit Guidance FAQ

Q: Can I replace a failed CC-TDOB01 without modifying my control strategy in Experion Builder?
A: Yes. A like-for-like replacement of the CC-TDOB01 does not require changes to the control strategy. The C300 controller automatically re-establishes communication with the new module over the I/O Link once it is seated and powered. No re-download of the control strategy is required in most cases; however, confirming the module status in Experion Station after insertion is recommended.

Q: Is field wiring re-termination necessary when swapping the CC-TDIL01?
A: No. The CC-TDIL01 uses the CC-TBOX01 or CC-TBRC01 terminal block, which remains in place during module replacement. Field wiring stays connected to the terminal block; only the I/O module itself is removed and replaced. This significantly reduces replacement time and eliminates the risk of wiring errors.

Q: What communication protocol does the CC-TDOB01 use, and is it compatible with third-party controllers?
A: The CC-TDOB01 uses Honeywell’s proprietary C300 I/O Link protocol. It is designed exclusively for the Experion PKS C300 platform and is not compatible with third-party controllers or other Honeywell controller families such as the HC900 or Safety Manager. If your migration involves a controller platform change, a full I/O re-engineering study is required.

Q: How much physical space does the CC-TDOB01 occupy in the cabinet?
A: The CC-TDOB01 occupies one slot in the C300 I/O chassis. Cabinet space planning should account for the chassis carrier, the terminal block, and adequate airflow clearance per Honeywell’s installation guidelines. No additional DIN rail or panel cutout is required for a like-for-like replacement.

Q: Can TOPNLMS provide pre-shipment testing documentation?
A: Yes. All modules undergo functional verification prior to shipment. A test report confirming module power-on status and basic I/O channel integrity is available upon request. This documentation supports incoming inspection and quality records at your facility.

Q: What is the lead time for CC-TDOB01 and CC-TDIL01?
A: In-stock units ship within 1–3 business days from Xiamen, China. Express courier options (DHL, FedEx, UPS) are available for urgent requirements. Estimated transit times vary by destination; contact us for a specific shipping quote.

Warranty Assurance

Every CC-TDOB01 and CC-TDIL01 module supplied by TOPNLMS is covered by a 12-month warranty from the date of shipment. This warranty covers manufacturing defects and functional failures under normal operating conditions consistent with Honeywell’s published specifications for the Experion PKS C300 platform.

Pre-shipment inspection: Each unit is powered on and subjected to a functional verification check before packaging. Modules that do not pass inspection are not shipped.

Replacement support: In the event of a warranty claim, TOPNLMS will arrange a replacement unit or issue a refund, subject to inspection of the returned module. Our goal is to resolve warranty cases within 5 business days of receiving the returned item.

After-sales response: Our technical team is reachable via email and phone for post-installation questions, commissioning support, and compatibility inquiries. We maintain records of all shipped units to facilitate rapid case resolution.

Procurement assurance: TOPNLMS issues a commercial invoice, packing list, and certificate of conformity with every shipment. These documents support customs clearance, asset registration, and internal procurement records. We accept T/T bank transfer and other standard B2B payment terms; contact us to discuss your procurement requirements.

Quick Inquiry

Click Quote This Model and the Part Number field will auto-fill with CC-TDOB01 CC-TDIL01.