Language English USD Currency
Call WhatsApp RFQ
Honeywell Industrial Automation Part

Honeywell CC-GAOX11 CC-GAOX21 Original Industrial Spare C300 Compatible

Request availability, condition, lead time and export shipping details for CC-GAOX11. CC-GAOX21.

Honeywell

CC-GAOX11. CC-GAOX21

Send this exact part number, quantity and destination country. TOPNLMS will confirm availability, condition and export lead time before quotation.

Part NumberCC-GAOX11. CC-GAOX21
CategoryI/O Module
ConditionAvailability Check
Lead TimeRFQ Confirmation
SeriesExperion PKS
ShippingExport packing available
Model checked before quotation Condition and packing confirmed Fast RFQ response by sales engineer

Product Overview

Honeywell CC-GAOX11 CC-GAOX21 Original Industrial Spare C300 Compatible: Sustaining System Stability in Critical Process Environments

In continuous-process industries — refining, petrochemicals, power generation, and specialty chemicals — the Honeywell Experion PKS C300 controller platform remains one of the most widely deployed distributed control systems in the world. Keeping that platform running without unplanned downtime depends entirely on the availability of verified, original spare parts. The Honeywell CC-GAOX11 and its functionally equivalent variant CC-GAOX21 are galvanically isolated intrinsically safe (IS) analog output cards designed specifically for the C300 I/O subsystem. Sourcing a genuine, tested replacement before a failure occurs is the single most effective action a maintenance team can take to protect production continuity.

Critical Technical Specifications

Parameter Specification
Part Numbers CC-GAOX11 / CC-GAOX21
Manufacturer Honeywell Process Solutions
Compatible Platform Experion PKS — C300 Controller Series
Module Type Galvanically Isolated IS Analog Output Card
Output Channels 8 channels (4–20 mA, HART-capable)
Isolation Galvanic channel-to-channel and channel-to-bus isolation
Hazardous Area Rating Intrinsically Safe (IS) — suitable for Zone 0/1 field devices
Communication Bus FTE (Fault Tolerant Ethernet) via C300 I/O Link
Power Supply Supplied via I/O Link — no separate field power required
Operating Temperature 0 °C to 60 °C
Mounting Standard Honeywell C300 I/O chassis — hot-swap capable
Firmware Compatibility Experion PKS R310 and above
Origin USA (Honeywell Process Solutions)
Condition Original / New-surplus, fully tested
Warranty 12 Months — covers functional defects under normal operating conditions

Preventive Maintenance Strategy: Protecting the C300 I/O Subsystem

A planned maintenance shutdown is the optimal window to audit the entire C300 I/O chassis. When a CC-GAOX11 or CC-GAOX21 analog output card is flagged for replacement — whether due to channel drift, HART communication faults, or a failed self-diagnostic — experienced maintenance engineers know that the surrounding modules deserve equal scrutiny. Galvanic isolation failures rarely occur in isolation; thermal cycling, humidity ingress, and aging power rails affect the entire card cage simultaneously.

Begin the inspection at the CC-PAIM01 / CC-PAIM11 analog input modules sharing the same I/O chassis. These cards handle 4–20 mA field signals from transmitters and are subject to the same environmental stresses as the output cards. A simultaneous audit prevents a second unplanned outage weeks after the first repair. Next, verify the health of the CC-TCF001 / CC-TCF901 I/O Link cables connecting the C300 controller to the I/O chassis — cable degradation is a common root cause of intermittent module faults that are incorrectly attributed to the card itself.

The CC-PWR001 / CC-PWR011 power supply modules feeding the I/O chassis should be load-tested during the same window. An aging power supply operating near its rated capacity will cause marginal output accuracy on analog cards long before it triggers a hard fault alarm. If the site runs a redundant power configuration, confirm that the standby unit switches cleanly under load.

For IS-rated output loops driving field actuators in hazardous areas, inspect the associated Honeywell IS barriers or galvanic isolators (such as the MTL or P+F series commonly paired with Experion IS I/O). Barrier degradation increases loop impedance and can cause the CC-GAOX11 to report output errors even when the card itself is healthy. Replacing the card without checking the barrier is a common and costly diagnostic error.

While the cabinet is open, check the CC-SCMB01 / CC-SCMB02 system cabinet backplane connectors and terminal blocks for corrosion or loose terminations. High-resistance connections in the field wiring introduce offset errors in 4–20 mA loops that are difficult to distinguish from card faults during online diagnostics. A torque check on all terminal screws and a visual inspection for oxidation takes less than 30 minutes and eliminates an entire category of future faults.

Finally, if the plant runs Experion PKS with redundant C300 controllers, confirm that the CC-PCNT01 controller module firmware is current and that the redundancy switchover has been tested within the last maintenance cycle. An output card replacement is an ideal trigger for a controlled redundancy failover test — validating both the new card and the controller redundancy in a single planned event.

Maintaining a minimum stock of one CC-GAOX11 and one CC-GAOX21 per C300 chassis in your on-site spare parts inventory is a widely adopted best practice in process industries with 24/7 production requirements. The lead time for sourcing original Honeywell C300 I/O modules through standard distribution channels can exceed 8–16 weeks; having a tested spare on the shelf reduces mean time to repair (MTTR) to under two hours.

Strategic Replacement Solutions: Extending Legacy System Life

Many Experion PKS C300 installations commissioned between 2005 and 2015 are now operating beyond their original design lifecycle. Honeywell’s official end-of-production notices for certain C300 I/O variants have prompted plant engineering teams to evaluate two paths: full migration to Experion PKS ControlEdge or a strategic spares-based life extension program.

For sites where a full DCS migration is not economically justified within the current capital planning cycle, the CC-GAOX11 and CC-GAOX21 provide a direct, drop-in replacement path. Both cards are pin-compatible and firmware-compatible with all C300 I/O chassis generations, requiring no configuration changes in Experion Builder beyond a module swap acknowledgment. This means a trained instrument technician can complete a hot-swap replacement in under 15 minutes with zero process interruption — provided the chassis is configured for redundant I/O or the loop can be placed in manual mode at the DCS console.

The galvanic isolation architecture of these cards also makes them the preferred choice when upgrading field wiring in older installations where ground loops were a recurring problem with earlier non-isolated output cards. Replacing a non-isolated legacy card with a CC-GAOX11 in the same chassis slot eliminates ground loop interference without any field wiring changes, delivering a measurable improvement in loop stability and reducing nuisance alarms on sensitive control loops.

For multi-site operators managing a fleet of Experion PKS systems, consolidating spare parts procurement around verified original modules — rather than mixing new-surplus and refurbished stock — simplifies quality assurance, warranty tracking, and regulatory compliance documentation. Each unit shipped from TOPNLMS is individually tested for output accuracy, channel isolation, and HART communication before dispatch.

Support FAQ

Q1: What is the difference between CC-GAOX11 and CC-GAOX21?
Both are galvanically isolated IS analog output cards for the Experion PKS C300 I/O subsystem. The CC-GAOX21 is the updated hardware revision of the CC-GAOX11, offering identical electrical specifications and full backward compatibility. Either card can be installed in the same chassis slot without configuration changes in Experion Builder. When ordering, specify your current installed revision to ensure the closest match, though both are interchangeable in practice.

Q2: How is each unit tested before shipment?
Every CC-GAOX11 and CC-GAOX21 unit undergoes a pre-shipment functional test covering all 8 output channels (4–20 mA accuracy), galvanic isolation integrity, HART communication handshake, and power consumption within rated limits. Test records are retained and available upon request for quality assurance documentation. Units that do not pass all test criteria are not shipped.

Q3: What does the 12-month warranty cover?
The 12-month warranty covers functional defects in materials and workmanship under normal operating conditions consistent with Honeywell’s published environmental and electrical specifications. It does not cover damage resulting from incorrect installation, overvoltage events, physical impact, or operation outside rated parameters. In the event of a warranty claim, TOPNLMS will arrange return logistics and provide a replacement or full refund at our discretion.

Q4: Can this card be used as a direct replacement for an older non-IS analog output card in the same C300 chassis?
The CC-GAOX11 and CC-GAOX21 are IS-rated cards and are designed for use in IS-configured I/O chassis slots. Installing an IS card in a non-IS chassis slot is technically possible but requires verification in Experion Builder that the slot is not configured for a non-IS module type. Consult your Experion PKS system documentation or contact your Honeywell system integrator before substituting IS and non-IS card types in the same chassis. TOPNLMS technical support can assist with compatibility verification prior to purchase.

Quick Inquiry

Click Quote This Model and the Part Number field will auto-fill with CC-GAOX11. CC-GAOX21.