Honeywell FS-CPCHAS-0001 Original Safety Manager Spare
FS-CPCHAS-0001Original Honeywell FS-CPCHAS-0001 CP Chassis for Safety Manager Series. Industrial spare for SIL-rated systems. Fast shipping, 12-month warranty. topnlms.com
Request availability, condition, lead time and export shipping details for 8C-TPOX01 51307022-175.
Send this exact part number, quantity and destination country. TOPNLMS will confirm availability, condition and export lead time before quotation.
The Honeywell 8C-TPOX01 (part number 51307022-175) is a wireless I/O backplane module designed for the Experion PKS Series C distributed control system platform. As Honeywell progressively phases out legacy Series C hardware, many process plants, refineries, and chemical facilities are facing the challenge of sourcing verified replacement units or planning a structured migration path to maintain system availability. TOPNLMS maintains ready stock of the 8C-TPOX01 51307022-175 to support both direct drop-in replacement and phased upgrade projects, ensuring your control system remains operational with minimal disruption.
The 8C-TPOX01 backplane serves as the physical and electrical backbone for Series C wireless I/O clusters. It provides the mounting interface, power distribution, and communication bus for field I/O modules installed within the same chassis. When replacing a failed or end-of-life unit, engineers must verify that the replacement carries the same firmware baseline and hardware revision to maintain compatibility with the existing C300 controller and its associated IOTA terminal assemblies. Our units are sourced from authorized channels, individually inspected, and shipped with full documentation to support your site acceptance test (SAT) procedures.
For facilities running mixed-generation Experion PKS architectures — where Series C backplanes coexist with earlier Series B hardware or newer Series D I/O — the 8C-TPOX01 replacement process requires careful attention to rack slot assignments, power budget calculations, and CHARMS (Configurable Hardware Agnostic Reliable Modular System) compatibility. Our technical team can advise on whether a direct swap is feasible or whether a broader chassis upgrade involving the 8C-PCNT01 C300 controller module or the 8C-PAIM01 analog input module is warranted.
| Parameter | Legacy / Outgoing Unit | 8C-TPOX01 51307022-175 (Replacement) |
|---|---|---|
| Part Number | Earlier 51307022-xxx revisions | 51307022-175 |
| Platform | Experion PKS Series B / Series C | Experion PKS Series C |
| Module Type | Wireless I/O Backplane | Wireless I/O Backplane |
| Communication Protocol | FTE (Fault Tolerant Ethernet) / Series C bus | FTE (Fault Tolerant Ethernet) / Series C bus |
| Mounting / Form Factor | Series C chassis rail mount | Series C chassis rail mount — direct fit |
| Power Supply Compatibility | 24 VDC Series C power rail | 24 VDC Series C power rail — no rewiring required |
| Wiring Interface | IOTA terminal assembly (existing) | Compatible with existing IOTA terminal assemblies |
| Controller Compatibility | C300 Process Controller | C300 Process Controller — no configuration change |
| Installation Space | Standard Series C cabinet footprint | Identical footprint — no cabinet modification needed |
| Replacement Recommendation | Direct swap for same-revision units | Verify firmware revision before hot-swap in live systems |
| Warranty | — | 12-Month Warranty from TOPNLMS |
A successful migration from a failed or obsolete 8C-TPOX01 backplane rarely involves a single component in isolation. In most Experion PKS Series C installations, the backplane works in concert with a broader set of hardware that must be evaluated during any upgrade or replacement project.
The 8C-PCNT01 C300 Process Controller is the primary controller that communicates with the 8C-TPOX01 backplane over the Series C FTE network. If the backplane replacement is part of a broader controller upgrade, the C300 firmware version must be aligned with the replacement backplane revision to avoid communication faults. Similarly, the 8C-PAIM01 Analog Input Module and 8C-PAOM01 Analog Output Module installed in the same chassis must be re-seated and verified after backplane replacement to confirm I/O channel integrity.
For sites where the 8C-TPOX01 supports wireless HART field devices, the associated 8C-PWRM01 Power and Radio Module must be inspected alongside the backplane swap, as power rail continuity directly affects wireless mesh network stability. If the replacement project extends to the field junction level, IOTA terminal assemblies (such as the 8C-TAIX02 or 8C-TAOX02 series) should be checked for corrosion or terminal wear, particularly in high-humidity or offshore environments.
Plants upgrading from Series B to Series C architecture will also need to account for the 8C-PCNT02 redundant controller module and the associated FTE network switches that form the backbone of the Experion PKS fault-tolerant communication layer. In cabinet-level retrofits, the 24 VDC Series C power supply module (such as the 8C-PWRM02) should be load-tested after backplane installation to confirm adequate current margin for the full I/O complement.
For programming and commissioning, the Honeywell Control Builder engineering workstation software is required to download and verify the I/O module configuration after backplane replacement. Sites without an active software maintenance agreement may need to source a compatible version to complete the SAT. Our team can advise on compatible software versions based on your controller firmware baseline.
Q: Can I replace the 8C-TPOX01 without rewiring field terminals?
A: Yes. The 8C-TPOX01 51307022-175 uses the same IOTA terminal assembly interface as previous Series C backplane revisions. Field wiring connected to the IOTA does not need to be disturbed during backplane replacement, significantly reducing replacement time and the risk of wiring errors.
Q: Is the 8C-TPOX01 compatible with my existing C300 controller configuration?
A: In most cases, yes. The replacement backplane communicates with the C300 over the standard Series C FTE bus. However, if the failed unit was running a significantly older firmware revision, a firmware alignment step may be required after installation. We recommend downloading the current I/O module configuration from Control Builder before the swap and reloading it post-installation to confirm channel assignments.
Q: What communication protocols does the 8C-TPOX01 support?
A: The 8C-TPOX01 operates within the Experion PKS Series C communication architecture, which uses Fault Tolerant Ethernet (FTE) for controller-to-backplane communication and supports wireless HART for field device integration. It does not natively support PROFIBUS or FOUNDATION Fieldbus without additional gateway modules.
Q: How much physical space does the replacement require?
A: The 8C-TPOX01 51307022-175 has an identical form factor to previous Series C backplane revisions. No cabinet modification, DIN rail adjustment, or additional mounting hardware is required for a direct replacement.
Q: Can this backplane be used in a redundant configuration?
A: The 8C-TPOX01 supports the standard Series C redundancy architecture when paired with a redundant C300 controller pair. Redundancy switchover behavior is governed by the C300 firmware and FTE network configuration, not the backplane itself.
Q: What should I check during commissioning after replacement?
A: After installing the replacement backplane, verify power rail voltage at the backplane connector, confirm FTE link status on both network ports, reload the I/O module configuration from Control Builder, and perform a channel-by-channel I/O verification against your loop drawings before returning the system to automatic control.
Every 8C-TPOX01 51307022-175 unit shipped by TOPNLMS is covered by a 12-month warranty from the date of delivery. Prior to shipment, each unit undergoes a multi-point inspection that includes visual examination for physical damage, connector integrity verification, and functional power-on testing where applicable. Units that do not pass inspection are quarantined and never shipped.
In the event of a warranty claim, TOPNLMS provides a replacement unit or full refund based on the nature of the defect and the customer’s preference. Our after-sales response target is 24 hours for initial acknowledgment and 72 hours for resolution proposal. For urgent plant situations involving unplanned downtime, we offer expedited processing and priority shipping to minimize production impact.
We maintain stock across multiple inventory positions to support both planned maintenance schedules and emergency breakdown orders. Standard lead time for in-stock units is 3–7 business days for international destinations, with express options available for time-critical situations. All units are shipped with commercial invoice, packing list, and inspection report to support customs clearance and your internal procurement records.
For volume procurement, long-term supply agreements, or technical pre-sales consultation, contact our team directly. We work with maintenance engineers, procurement managers, and system integrators across the process industries to ensure reliable access to critical Honeywell Experion PKS spare parts.
Click Quote This Model and the Part Number field will auto-fill with 8C-TPOX01 51307022-175.